GE DS3820PSCC1D1B

¥999.00

The DS3820PSCC1D1B is a 4‑channel analog input module designed for Pt100 RTD temperature sensors, offering high‑precision 24‑bit resolutionper‑channel isolationautomatic lead compensationbuilt‑in diagnostics1500 V isolationenhanced EMI noise rejection (CMRR > 120 dB), and screw‑type terminals with a fixed mixed terminal configuration (1D1B suffix). It supports 2‑wire, 3‑wire, or 4‑wire Pt100 configurations with software‑configurable excitation current and per‑channel open/short detection. The DS3820PSCC1D1B features premium accuracy (±0.03°C) and is specifically optimized for high‑EMI environments, making it the top‑tier, plug‑and‑play Pt100 solution for demanding applications where both precision and electrical noise immunity are critical, with traditional screw‑terminal wiring for secure panel installations.

Category:

Description

Key Parameters

  • Channels: 4 isolated analog inputs

  • Sensor Type: Pt100 (2‑wire, 3‑wire, or 4‑wire – software‑configurable per channel)

  • Resolution: 24‑bit ADC

  • Accuracy: ±0.03°C (Pt100, 25°C); ±0.12°C over –40°C to +70°C

  • Excitation Current: Software‑selectable 0.1 mA, 0.5 mA, 1 mA (per channel)

  • Lead Resistance Compensation: Automatic for 3‑wire and 4‑wire configurations

  • Measurement Range: –200°C to +850°C

  • EMC/Noise Rejection: Enhanced CMRR > 120 dB, built‑in 50/60 Hz digital filtering

  • Diagnostics: Open‑circuit detection, short‑circuit detection, over‑range/under‑range, signal‑loss detection, per‑channel LED status

  • Isolation: 1500 V RMS (field‑to‑backplane); 500 V RMS between channels (per‑channel isolation)

  • Sampling Rate: Up to 50 Hz per channel (with noise rejection filtering enabled)

  • Terminal Type: Screw‑type – per suffix “C1D1B”

  • Power: 24 V DC backplane power, ≤4 W

  • Operating Temperature: –40°C to +70°C


Advantages

  • Pre‑configured – fixed terminal configuration; reduces setup time and engineering effort.

  • Screw‑type terminals – familiar and secure wiring for traditional panel installations; offers reliable connections in low‑ to moderate‑vibration environments.

  • Enhanced noise immunity – CMRR > 120 dB and advanced digital filtering; ideal for installations near VFDs, inverters, and high‑power switching equipment.

  • Premium accuracy – ±0.03°C; the highest precision Pt100 module in the family.

  • 24‑bit resolution – provides superior measurement fidelity for demanding applications.

  • Per‑channel isolation – 500 V between channels; prevents ground loops and cross‑channel interference.

  • Automatic lead compensation – for 3‑wire/4‑wire RTDs, cancels lead resistance errors for accurate temperature readings.

  • Software‑configurable per channel – wire configuration and excitation current independently settable.

  • Built‑in linearization – provides direct temperature readout in °C or °F; no scaling required.

  • Enhanced diagnostics – includes signal‑loss detection for proactive maintenance.

  • Open/short detection – detects broken wires or sensor shorts instantly.

  • Hot‑swappable – replace without rack power‑down.

  • Wide measurement range – –200°C to +850°C covers most industrial applications.


Applications

  • VFD‑controlled motor systems – bearing and winding temperature monitoring near variable frequency drives

  • Steel mills & foundries – temperature monitoring near high‑power equipment

  • Power generation – turbine bearing and generator temperature monitoring in substation environments

  • Oil & gas – pipeline and compressor temperature monitoring with surge protection

  • Semiconductor manufacturing – precision chamber temperature control with high noise immunity

  • Metrology & calibration labs – high‑precision temperature measurement and sensor verification

  • Chemical processing – reactor and pipeline temperature monitoring in high‑EMI areas

  • Research & development – experimental thermal analysis in high‑EMI labs


Competitor Comparison

Feature DS3820PSCC1D1B DS3820PSCC (Configurable Screw) Standard Pt100 Module (16‑bit)
Channels 4 4 4
Resolution 24‑bit 24‑bit 16‑bit
Accuracy ±0.03°C ±0.03°C ±0.05°C
Noise Rejection (CMRR) >120 dB >120 dB >90 dB
Diagnostics Enhanced (signal‑loss) Enhanced Basic
Per‑channel Isolation Yes (500 V) Yes (500 V) Group only
Terminal Type Screw‑type Screw‑type Screw‑type
Configuration Fixed (suffix) Software‑configurable Software‑configurable
Setup Time Instant Moderate Moderate
Cost High High Low

The DS3820PSCC1D1B is the fixed‑configuration, EMI‑optimized, screw‑terminal premium Pt100 input module with ±0.03°C accuracy. Compared to the configurable DS3820PSCC (same core performance), it offers plug‑and‑play simplicity while maintaining superior noise rejection (CMRR > 120 dB) and the same highest accuracy. Against standard Pt100 modules, it provides superior resolution (24‑bit vs. 16‑bit), enhanced diagnostics, and EMI resilience – all with zero configuration effort. For demanding Pt100 applications requiring both the highest accuracy and the highest noise immunity with traditional screw‑terminal wiring, the DS3820PSCC1D1B delivers the best‑in‑class, deployment‑ready solution.


Selection Tips

  • Choose DS3820PSCC1D1B when you need maximum precision (±0.03°C) for Pt100 temperature measurement with screw‑terminal wiringsuperior EMI noise immunity, and plug‑and‑play simplicity.

  • Ideal for VFD‑heavy installations, substations, steel mills, power generation, oil & gas, and chemical processing applications where electrical noise is a significant concern.

  • Verify the wire configuration (2‑wire, 3‑wire, or 4‑wire) – software‑configurable per channel.

  • Confirm the terminal configuration (1D1B) matches your panel wiring requirements.

  • For 2‑wire sensors, lead resistance adds error – use 3‑wire or 4‑wire for accurate measurements.

  • Not suitable for Pt1000, Ni RTDs, or thermocouples – use dedicated modules.

  • Ensure your PLC/DCS can handle 24‑bit data resolution from the DS3820PSCC1D1B.


Precautions

  • Lead resistance: For 2‑wire sensors, lead resistance directly adds error – use 3‑wire or 4‑wire for accurate measurements. The DS3820PSCC1D1B compensates for 3‑wire/4‑wire automatically.

  • Excitation current: Higher currents (1 mA) produce self‑heating errors in small Pt100 elements – use 0.1 mA or 0.5 mA for sensitive sensors.

  • Wiring: Use shielded twisted‑pair cables; ground shield at module end only. Enhanced EMI protection requires proper grounding to achieve >120 dB CMRR.

  • Signal‑loss detection: Requires minimum sensor impedance – very low‑impedance sensors may not trigger detection.

  • Power sequencing: Apply backplane power before field power.

  • Calibration: Perform periodic calibration using precision resistors to maintain ±0.03°C accuracy – the DS3820PSCC1D1B requires regular verification to maintain specification.

  • Spare: Keep one spare DS3820PSCC1D1B for critical high‑precision loops – the fixed configuration is typically stocked for quick replacement.

A-B 1756-BA2
A-B 1747-BA
A-B MVI56-MCM

Reviews

There are no reviews yet.

Be the first to review “GE DS3820PSCC1D1B”

Your email address will not be published. Required fields are marked *

Post comment