The DS3820AISA1A1A is an 8-channel analog input module featuring simultaneous sampling with a factory-fixed input configuration and specific terminal block type. It captures all 8 channels at the exact same instant with 16-bit resolution, 1500 V isolation, and a pre-set input range (4–20 mA or 0–10 V per suffix). The fixed configuration makes it a plug-and-play solution for power monitoring and dynamic process applications requiring time-coherent measurements without software setup.

Category:

Description

Key Parameters

  • Channels: 8 differential

  • Inputs: 4–20 mA or 0–10 V (fixed per suffix – verify before ordering)

  • Sampling Mode: Simultaneous (all channels sampled at same instant)

  • Resolution: 16-bit ADC

  • Sampling Rate: Up to 1 kHz per channel (simultaneous, global)

  • Accuracy: ±0.1% FS (25°C); ±0.3% over –40°C to +70°C

  • Phase Mismatch: < 0.1° at 50/60 Hz (between channels)

  • Isolation: 1500 V RMS field-to-logic (group isolated)

  • Power: 24 V DC, ≤6 W

  • Diagnostics: Open-circuit, over/under-range, watchdog timer

  • CMRR: >100 dB


Advantages

  • Simultaneous sampling – captures all 8 channels precisely at the same moment; eliminates phase errors between signals.

  • Pre-configured – no software calibration or channel setup needed; ready to use immediately.

  • High-speed sampling – up to 1 kHz per channel for dynamic monitoring.

  • Minimal phase mismatch – < 0.1° at 50/60 Hz ensures accurate power and vector calculations.

  • Hot-swappable – replace without rack power-down.

  • Built-in diagnostics – alerts for broken wires and out-of-range conditions.


Applications

  • Power monitoring – 3-phase voltage and current measurements (V, A, W, VAR, PF)

  • Motor control – simultaneous current and voltage monitoring for efficiency calculations

  • Vibration analysis – multi-axis accelerometer data capture for predictive maintenance

  • Hydraulic systems – pressure and flow monitoring requiring time-correlated data

  • Test & measurement – dynamic process characterization and transient recording

  • Renewable energy – solar inverter and wind turbine output monitoring


Competitor Comparison

Feature DS3820AISA1A1A Standard Sequential AI Competitor Simultaneous AI
Sampling Mode Simultaneous Sequential Simultaneous
Phase Mismatch < 0.1° Up to 5° (at 60 Hz) < 0.2°
Max Sampling Rate 1 kHz/ch 250 Hz/ch 1 kHz/ch
Configuration Fixed (factory) Software/Jumper Software
Setup Time Instant Moderate Moderate
Cost Mid Low High

The DS3820AISA1A1A delivers premium simultaneous sampling performance with zero engineering configuration effort. Compared to standard sequential-scan modules, it eliminates phase delays that can cause significant errors in power calculations. Against competitor simultaneous modules, the DS3820AISA1A1A offers comparable performance at a lower price, with the added advantage of instant deployment – ideal for standardized systems. The fixed configuration makes the DS3820AISA1A1A the most cost-effective choice for large-scale installations with uniform signal types.


Selection Tips

  • Choose DS3820AISA1A1A when you need time-coherent measurements across channels AND your signal type is fixed (4–20 mA or 0–10 V).

  • Ideal for 3-phase power systems (use 3 channels for voltage, 3 for current, 2 spare) in standardized installations.

  • Verify the suffix exactly matches your sensor/transmitter output – the DS3820AISA1A1A is not field-reconfigurable.

  • Not suitable if you need mixed signal types on the same module – consider the software-configurable DS3820AISA instead.

  • Ensure your controller can handle the 1 kHz data throughput.


Precautions

  • Wiring: Use shielded twisted-pair cables to maintain signal integrity at higher sampling rates.

  • Grounding: Maintain single-point grounding to avoid high-frequency noise.

  • Power sequencing: Apply backplane power before field power.

  • Cooling: Ensure adequate airflow in dense racks – dissipates up to 6 W.

  • Data throughput: High sampling rates generate significant traffic – ensure bus bandwidth is sufficient.

  • Spare: Keep one spare DS3820AISA1A1A for critical monitoring loops.

  • Configuration verification: Confirm the fixed input range matches your sensors before installation – no field adjustment is possible.

SIEMENS 3SB34001PE
SCHNEIDER LADN22C
SCHNEIDER GR-2C-AC220V+PGR-2C-E

Reviews

There are no reviews yet.

Be the first to review “GE DS3820AISA1A1A”

Your email address will not be published. Required fields are marked *

Post comment