GE DS3820AIPA

¥999.00

The DS3820AIPA is an 8-channel analog input module for DCS/PLC backplanes, accepting 4–20 mA, 0–10 V, or ±10 V signals with 16-bit resolution. It is designed for reliable process monitoring in industrial environments.

Category:

Description

Key Parameters

  • Channels: 8 differential (software-configurable per channel)

  • Inputs: 4–20 mA, 0–20 mA, 0–5 V, 0–10 V, ±10 V

  • Resolution: 16-bit ADC

  • Accuracy: ±0.1% FS (25°C); ±0.3% over full temp range

  • Isolation: 1500 V RMS (field-to-logic)

  • Power: 24 V DC, ≤5 W

  • Temp Range: –40°C to +70°C

  • Diagnostics: Open-circuit, over/under-range, watchdog


Advantages

  • Software-configurable – no jumpers needed; change settings via controller software.

  • Hot-swappable – replace without powering down the rack.

  • High noise immunity – CMRR > 90 dB, works near VFDs and heavy switchgear.

  • Built-in fault detection – alerts for broken wires or sensor shorts.


Applications

  • Oil & gas – pressure/temperature monitoring on pipelines.

  • Water treatment – flow and level sensing in pump stations.

  • Power plants – turbine bearing temps and steam pressure.

  • Pharma – cleanroom differential pressure for batch control.


Competitor Comparison

Feature DS3820AIPA Basic 8-ch AI (Jumper) Premium Isolated AI
Config Software Hardware jumper Software
Isolation Group Group Per-channel
Hot-swap Yes No Yes
Diagnostics Full Over-range only Full
Cost Mid Low High (2.5x)

The DS3820AIPA beats basic cards with better diagnostics and flexibility, while undercutting premium models by avoiding unnecessary per-channel isolation costs.


Selection Tips

  • Choose DS3820AIPA if you need mixed signal types on one module and software reconfigurability..

    • Verify compatibility with your CPU firmware before ordering.

    • Not suitable for >500 Hz sampling or per-channel isolation requirements.


    Precautions

    • Wiring: Use shielded twisted-pair; ground shield at module end only.

    • Polarity: No reverse-polarity protection – double-check field wiring.

    • Power: Apply backplane power before sensor power.

    • Cooling: Ensure airflow in high-density racks to avoid overheating.

    • Spare: Keep one spare DS3820AIPA for critical loops during maintenance.

Schneider A9F18106
SIEMENS 5SY61167CC
Schneider RXM4AB2BD

Reviews

There are no reviews yet.

Be the first to review “GE DS3820AIPA”