Description
Key Parameters
-
Memory Type: Battery-backed SRAM with integrated real-time clock (RTC)
-
Memory Capacity: 2MB or 4MB (depending on configuration)
-
Time-Stamp Resolution: 0.5ms (improved over standard 1ms)
-
Real-Time Clock: Integrated RTC with battery backup (maintains time during power loss)
-
Time-Stamp Accuracy: ±1 second per day (improved temperature compensation – firmware 1A1A)
-
Data Retention: >10 years with battery (battery-backed memory)
-
Battery: Field-replaceable lithium 3.6V (life ~5 years) – separate battery for RTC backup
-
Battery Monitoring: Enhanced on-board voltage and capacity monitoring for both memory and RTC batteries (firmware 1A1A), low-battery alarm
-
Diagnostics: LED status (power, battery, RTC, activity), enhanced self-test on power-up, RTC health indication, expanded fault logging (firmware 1A1A)
-
Event Logging: Configurable event buffers with improved timestamp precision (0.5ms)
-
Isolation: 2500V RMS memory-to-backplane (enhanced)
-
Temp Range: –40°C to +85°C (extended)
-
Power Supply: +5V (logic) from backplane; battery backup for memory and RTC
-
Physical: 6U VME single-slot board
-
Key Features: Battery-backed memory + RTC, 0.5ms time-stamp resolution, enhanced event logging, dual battery monitoring with capacity estimation, self-test, 2500V isolation, extended temp range, firmware rev 1A1A
Advantages
-
High-accuracy time-stamping – the DS3810MTRA1A1A provides 0.5ms time-stamp resolution, enabling precise correlation of turbine events, alarms, and trips for detailed root-cause analysis.
-
Improved time accuracy – ±1 second per day accuracy (improved over standard ±2 seconds/day) ensures consistent time-stamps across long operational periods.
-
Integrated RTC with battery backup – maintains accurate time even during extended power outages.
-
Comprehensive event logging – stores trip events, alarms, operator actions, and analog value snapshots with improved timestamp precision.
-
Enhanced battery diagnostics – the General Electric DS3810MTRA1A1A provides both voltage and capacity monitoring for memory and RTC batteries, enabling proactive replacement.
-
Enhanced diagnostics – the 1A1A firmware provides improved fault logging, self-test on power-up, and RTC health indication for predictive maintenance.
-
Enhanced isolation – 2500V RMS isolation protects the board from backplane noise and transients.
-
Extended temperature range – operates from –40°C to +85°C for harsh environments.
-
Drop-in compatible – works with all Mark IV backplanes and processor configurations.
Applications
-
Turbine event recording – records trip events, alarm activations, and operator actions with precise 0.5ms time-stamps for advanced root-cause analysis.
-
Fault diagnosis – time-correlated event logs help identify sequence-of-events leading to turbine trips, enabling faster troubleshooting.
-
Sequence-of-events (SOE) recording – the General Electric DS3810MTRA1A1A provides high-resolution time-stamping for critical SOE applications.
-
Performance trending – stores operational data with time-stamps for performance analysis and predictive maintenance.
-
Offshore and harsh environments – extended temperature range makes it suitable for demanding applications.
-
Compliance and reporting – maintains detailed, time-stamped logs for regulatory compliance.
vs Competitors & Previous Variants
| Feature | DS3810MTRA1A1A | Standard DS3810MTRA | DS3810MMAB1A1A (Memory only) | External SOE Recorder |
|---|---|---|---|---|
| Time-stamp resolution | 0.5ms | 1ms | None | 1ms |
| Time accuracy | ±1 sec/day | ±2 sec/day | N/A | ±2 sec/day |
| Memory capacity | 2–4MB | 2–4MB | 2–4MB | Varies |
| Battery monitoring | Enhanced (capacity + voltage) | Voltage only | Enhanced (memory only) | Varies |
| Self-test on power-up | Yes (1A1A) | Yes | Yes | No |
| Fault logging | Expanded (1A1A) | Standard | Expanded | Varies |
| Isolation | 2500V | 1500V | 2500V | Varies |
| Extended temp range | –40°C to +85°C | –30°C to +70°C | –40°C to +85°C | 0°C to +50°C |
| Firmware revision | 1A1A | Varies | 1A1A | N/A |
Selection Tips
-
High-precision SOE logging – choose the DS3810MTRA1A1A when you require the highest time-stamp resolution (0.5ms) for sequence-of-events recording and fault diagnosis.
-
Harsh environments – the extended temperature range makes it suitable for offshore, desert, or unheated cabinet installations.
-
Enhanced battery management – the General Electric DS3810MTRA1A1A provides both voltage and capacity monitoring for proactive battery replacement.
-
Time accuracy – the improved ±1 second/day accuracy is ideal for applications requiring consistent time-stamps over long operational periods.
-
Firmware compatibility – confirm your Mark IV main processor firmware supports the enhanced features of the DS3810MTRA1A1A.
-
Battery replacement – replace batteries when the low-battery alarm or reduced capacity indication is active.
-
Spare strategy – keep one DS3810MTRA1A1A per 5–8 installed units, especially in critical SOE applications.
-
Pre-installation verification – verify battery voltages and RTC accuracy before installation.
-
Configuration – configure the event logging parameters (buffer size, events to log) to match your application requirements.
Critical Precautions
-
Battery handling – replace the batteries on the DS3810MTRA1A1A only with the specified lithium 3.6V type. Use correct polarity for both the memory and RTC batteries.
-
Battery replacement procedure – when replacing batteries, ensure the board is powered (or data/event logs are backed up) to prevent data loss.
-
Data backup – before any maintenance, export all event logs and configuration data using the Mark IV system tools.
-
RTC accuracy – verify the RTC accuracy of the General Electric DS3810MTRA1A1A periodically (±1 second/day).
-
Time synchronization – if the Mark IV system has a master time source, ensure the DS3810MTRA1A1A RTC is synchronized to maintain consistent time-stamps.
-
Event log management – configure the event buffer size appropriately; if the buffer fills, older events may be overwritten.
-
ESD handling – always use a grounded wrist strap; CMOS memory and RTC components are ESD-sensitive.
-
Battery disposal – dispose of lithium batteries according to local environmental regulations.
-
Hot-swap – never insert or remove the DS3810MTRA1A1A while the rack is powered.
-
Low-battery alarm – if the low-battery alarm or reduced capacity indication is active for either battery, replace the affected battery as soon as possible.
-
Storage – store spare DS3810MTRA1A1A boards in anti-static bags in a dry, temperature-controlled environment. Batteries should be stored separately if the board will be in storage for more than 6 months.
-
Battery shelf life – check the battery date codes before installation; batteries have a limited shelf life (typically 5 years from manufacture).

Panasonic BR-AGCF2W 6V
A-B 1734-TB
PANASONIC BR-AGCF2W
PANASONIC BR-AGCF2W 6V