Description
Key Parameters
-
Memory Type: Battery-backed SRAM (non-volatile)
-
Memory Capacity: 1MB or 2MB (depending on configuration)
-
Data Retention: >10 years with battery (battery-backed)
-
Battery: Field-replaceable lithium 3.6V (life ~5 years)
-
Battery Monitoring: On-board voltage monitoring and low-battery alarm
-
Storage Content: Turbine control parameters, setpoints, tuning constants, calibration data, fault logs, event history
-
Access Time: <100ns (high-speed access for processor)
-
Diagnostics: LED status (power, battery, activity), self-test on power-up, battery health indication
-
Isolation: 1500V RMS memory-to-backplane
-
Temp Range: –30°C to +70°C
-
Power Supply: +5V (logic) from backplane; battery backup for data retention
-
Physical: 6U VME single-slot board
-
Key Features: Battery-backed SRAM, 1–2MB capacity, low-battery alarm, self-test, battery health monitoring
Advantages
-
Data persistence – the DS3810MMAB preserves critical turbine control parameters through power cycles, ensuring reliable startup and operation without manual re-entry of setpoints.
-
Battery-backed reliability – the field-replaceable lithium battery provides >10 years of data retention, with on-board monitoring to alert when battery replacement is needed.
-
High-speed access – <100ns access time ensures the General Electric DS3810MMAB does not become a bottleneck for processor performance.
-
Comprehensive storage – stores turbine control parameters, tuning constants, calibration values, fault logs, and event history in a single module.
-
Low-battery alarm – the General Electric DS3810MMAB provides early warning of battery depletion, allowing proactive replacement before data loss occurs.
-
Self-test on power-up – verifies memory integrity and battery health at system startup, ensuring reliable operation.
-
Drop-in compatible – works with all Mark IV backplanes and processor configurations.
Applications
-
Turbine configuration storage – the DS3810MMAB stores critical turbine parameters such as fuel valve characteristics, IGV calibration curves, and speed control setpoints.
-
Fault and event logging – records trip events, alarms, and operator actions for root-cause analysis and maintenance planning.
-
Tuning constant storage – stores PID tuning constants and control loop parameters for consistent turbine performance.
-
System startup – the General Electric DS3810MMAB ensures the turbine control system has immediate access to all required parameters on power-up.
-
Retrofits – replaces older memory modules with higher capacity and improved battery monitoring.
vs Competitors & Previous Variants
| Feature | DS3810MMAB | DS3800NVMB (512KB) | Generic VME Memory Board |
|---|---|---|---|
| Memory capacity | 1–2MB | 512KB | 128KB–1MB |
| Data retention | >10 years | >10 years | 5–10 years |
| Battery monitoring | Yes (voltage + alarm) | Limited | Rarely |
| Low-battery alarm | Yes | No | No |
| Self-test on power-up | Yes | No | No |
| Access time | <100ns | <100ns | 100–200ns |
| Isolation | 1500V | 1500V | 500–1500V |
| Temp range | –30°C to +70°C | –30°C to +70°C | 0°C to +60°C |
Selection Tips
-
Storage capacity – choose the DS3810MMAB for applications requiring more storage capacity (1–2MB) than the older DS3800NVMB (512KB), such as extensive fault logging or large configuration datasets.
-
Battery monitoring – the General Electric DS3810MMAB provides on-board battery voltage monitoring and low-battery alarm, enabling proactive maintenance.
-
Data criticality – for applications where turbine parameters are critical and cannot be lost, the DS3810MMAB battery-backed design ensures data persistence.
-
Battery replacement – the battery on the DS3810MMAB is field-replaceable. Plan for replacement every 5 years or when the low-battery alarm indicates.
-
Spare strategy – keep one DS3810MMAB per 5–8 installed units, especially in systems where configuration data and fault logs are critical.
-
Pre-installation verification – verify battery voltage before installation to ensure data retention capability.
Critical Precautions
-
Battery handling – replace the battery on the DS3810MMAB only with the specified lithium 3.6V type. Use correct polarity; reversed installation can damage the board.
-
Battery replacement procedure – when replacing the battery on the General Electric DS3810MMAB, ensure the board is powered (or data is backed up) to prevent data loss during replacement.
-
Data backup – before performing any maintenance on the DS3810MMAB, export all critical configuration data using the Mark IV system tools to ensure recoverability.
-
ESD handling – always use a grounded wrist strap when handling the DS3810MMAB; CMOS memory components are ESD-sensitive.
-
Battery disposal – dispose of the DS3810MMAB lithium battery according to local environmental regulations.
-
Hot-swap – never insert or remove the DS3810MMAB while the rack is powered; this can cause data corruption or bus errors.
-
Low-battery alarm – if the low-battery alarm is active on the DS3810MMAB, replace the battery as soon as possible to prevent data loss.
-
Storage – store spare DS3810MMAB boards in anti-static bags in a dry, temperature-controlled environment. Batteries should be stored separately if the board will be in storage for more than 6 months.
-
Battery shelf life – check the battery date code on the DS3810MMAB before installation; batteries have a limited shelf life (typically 5 years from manufacture).


PANASONIC BR-AGCF2W 6V
A-B SJ202-C6
PANASONIC BR-AGCF2W 6V
PANASONIC BR-2/3AGCT4A 6V