Description
Key Parameters
-
Output Channels: 8 or 16 independent digital outputs (depending on configuration)
-
Output Type: High-side or low-side solid-state drivers (jumper-selectable)
-
Output Voltage: 24V DC or 48V DC (field-selectable)
-
Output Current: 2A per channel (continuous), 4A peak (short duration) – higher than standard boards
-
Load Monitoring: Per-channel current sensing for load fault detection (open circuit, short circuit, overload)
-
Isolation: 2500V RMS channel-to-backplane (enhanced)
-
Diagnostics: Per-channel LED status, load fault indication, over-temperature protection, fault feedback to processor
-
Response Time: <2ms (turn-on/turn-off)
-
Temp Range: –40°C to +85°C (extended)
-
Power Supply: +5V (logic), +24V/48V (field power) from backplane or external supply
-
Physical: 6U VME single-slot board
-
Key Features: High-current outputs (2A), load monitoring, short-circuit protection, per-channel fault feedback, extended temp range
Advantages
-
High-current capability – the DS3810CLCB provides 2A continuous output current per channel, enabling direct control of larger loads without external interposing relays.
-
Built-in load monitoring – per-channel current sensing detects open circuits, short circuits, and overloads, providing valuable diagnostic information to the processor.
-
Solid-state outputs – no mechanical contacts to wear out, providing faster switching and longer service life than relay-based outputs.
-
Comprehensive protection – short-circuit, over-current, and thermal protection on each channel safeguard the General Electric DS3810CLCB and connected field devices.
-
Fault feedback – each channel provides load status feedback to the processor, enabling predictive maintenance and rapid troubleshooting.
-
Field-configurable – jumper-selectable for high-side or low-side output and 24V or 48V operation.
-
High isolation – 2500V RMS isolation protects the backplane and processor from field-side faults.
-
Extended temperature range – operates from –40°C to +85°C for harsh environments.
-
Drop-in compatible – works with all Mark IV backplanes and processor configurations.
Applications
-
Large solenoid valve control – the General Electric DS3810CLCB drives large fuel shut-off valves, steam dump valves, and isolation valves requiring higher current.
-
Motor contactor control – directly drives contactor coils for pumps, fans, and cooling systems.
-
Heater control – controls electric heaters for lube oil, fuel gas, or other process heating applications.
-
Load monitoring applications – provides real-time load status for critical circuits where open-circuit or short-circuit detection is essential.
-
Offshore and harsh environments – extended temperature range and high reliability make it suitable for demanding applications.
-
Retrofits – replaces older high-current output boards with enhanced diagnostics.
vs Competitors & Previous Variants
| Feature | DS3810CLCB | DS38080HRDB (High-Reliability) | DS3800NVRC (Relay) | Generic VME High-Current Board |
|---|---|---|---|---|
| Output current | 2A | 0.5A | 5A | 1–2A |
| Output type | Solid-state | Solid-state | Form-C relay | Solid-state or relay |
| Load monitoring | Yes (per channel) | No | No | Rarely |
| Short-circuit protection | Yes | Yes | No | Sometimes |
| Fault feedback | Yes | Yes | No | Rarely |
| Isolation | 2500V | 2500V | 2500V | 500–1500V |
| Extended temp range | –40°C to +85°C | –40°C to +85°C | –30°C to +70°C | 0°C to +60°C |
| Response time | <2ms | <1ms | 10–15ms | 1–5ms |
| Mechanical wear | None | None | Yes (relay contacts) | Varies |
Selection Tips
-
High-current loads – choose the DS3810CLCB when your field devices require up to 2A continuous current and you want direct control without external interposing relays.
-
Load monitoring required – the per-channel load monitoring of the General Electric DS3810CLCB is ideal for critical circuits where open-circuit or short-circuit detection is essential for safety or diagnostics.
-
Reliability requirements – the solid-state design eliminates mechanical wear, making it suitable for high-cycle applications.
-
Field voltage matching – verify that your field devices operate at 24V or 48V DC, and configure the DS3810CLCB jumpers accordingly.
-
Load current verification – ensure the 2A continuous current rating of the DS3810CLCB is sufficient for your loads. For loads exceeding 2A, use external contactors or consider relay-based boards.
-
Spare strategy – keep one DS3810CLCB per 5–8 installed units, especially in critical applications with high-current loads.
-
Pre-installation testing – verify output functionality and load monitoring using the on-board diagnostic LEDs and processor feedback.
Critical Precautions
-
Output current limits – do not exceed 2A continuous per channel on the DS3810CLCB. Overloading can trigger thermal shutdown or damage the output stage.
-
Inductive loads – for solenoid and relay coil loads, install a flyback diode (for DC loads) across the load to prevent voltage spikes that can damage the General Electric DS3810CLCB output stage.
-
Field voltage selection – ensure the DS3810CLCB jumpers are correctly set for 24V or 48V operation before applying field power. Incorrect settings can damage the outputs.
-
High-side vs low-side – configure the jumper for high-side or low-side output to match your field device wiring; incorrect configuration can cause malfunction or damage.
-
Wiring polarity – observe correct polarity when connecting field devices to the DS3810CLCB outputs; reversed polarity can cause malfunction or damage.
-
Load monitoring calibration – verify the current sensing thresholds of the DS3810CLCB against your actual load currents to ensure accurate fault detection.
-
Cable sizing – use appropriately sized cables for high-current outputs to prevent voltage drop and overheating of the DS3810CLCB terminal connections.
-
Heat dissipation – ensure adequate cabinet cooling; the DS3810CLCB generates significant heat under full load. Derating may apply at high temperatures; consult the technical manual.
-
Fault handling – if a load fault is reported, verify the field wiring and load before resetting or replacing the DS3810CLCB.
-
Hot-swap – never insert or remove the DS3810CLCB while the rack is powered; this can cause bus errors or damage.
-
ESD handling – always use a grounded wrist strap when handling the DS3810CLCB; CMOS and power components are ESD-sensitive.
-
Storage – store spare DS3810CLCB boards in anti-static bags in a dry, temperature-controlled environment.

A-B 1756-N2
A-B 700-HA32Z24
IFM E11589