Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 90–160 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 8A (precision logic), ±15 VDC / 2A (each rail, precision analog) |
| Isolation | Full isolation (1.5kV input‑to‑output, 2.0kV output‑to‑ground) |
| Protection | Overcurrent protection (adjustable per output via jumpers), short‑circuit protection, transient suppression (6kV surge), reverse polarity protection, input undervoltage lockout |
| Regulation | Load regulation: ±0.03%; Line regulation: ±0.01%; Temperature coefficient: < 30 ppm/°C |
| Ripple | < 3mVpp (+5V), < 2mVpp (±15V) |
| Temperature Compensation | Active dual‑zone temperature compensation with heatsink‑mounted sensor for improved thermal tracking |
| Communication Interface | RS‑485/Modbus and Ethernet/Modbus TCP for external device communication; communicates with main CPU via backplane |
| Diagnostic Features | Onboard diagnostic engine for power supply health monitoring; predictive failure indicators (capacitor ESR, MOSFET health); event logging (5,000‑event buffer) |
| Monitoring | 6 analog feedback channels (voltage and current monitoring for outputs + input monitoring); 4 digital fault outputs (relay, 24V/1A) for system faults and diagnostic alerts |
| Digital Interface | 4 digital inputs for external control; 6 digital outputs for status indication |
| Operating Temperature | –30°C to +65°C |
| Form Factor | 6U × 6HP (30mm) – requires 1.5 slots |
| Backplane Connector | Standard VME 96‑pin P1 + reinforced 60‑pin P2 |
| Status LEDs | 8 indicators: INPUT OK (green), OUTPUT OK (green), SYSTEM OK (green), FAULT (red), COMM ACTIVE (white), DIAGNOSTIC ALERT (orange), OVERTEMP (yellow), PREDICTIVE ALERT (purple) |
| Certifications | CE, UL 508, CSA Class I Div 2, IEC 61508 SIL 2 (TÜV‑certified) |
| Efficiency | ~80% at full load |
Critical note: The DS3800NTCF is a temperature‑compensated power board with communications, enhanced diagnostics, and SIL 2 certification. It is physically wider (6HP) than standard 4HP boards and requires 1.5 adjacent slots. Hot‑swapping is not supported.
Key Features & Advantages
-
Ultra‑Low Temperature Drift – < 30 ppm/°C with dual‑zone compensation.
-
Dual Communication Interfaces – RS‑485/Modbus and Ethernet/Modbus TCP.
-
Predictive Analytics – Monitors capacitor ESR and MOSFET health; purple LED warns before failure.
-
Event Logging – 5,000‑event buffer for failure analysis.
-
Comprehensive Monitoring – Six analog channels for outputs and input status.
-
Four Fault Relays – Separate fault indication for system faults and diagnostic alerts.
-
SIL 2 Certification – TÜV‑certified for functional safety.
-
Wide Temperature Range – –30°C to +65°C.
Typical Application Cases
-
Critical Instrumentation Cabinets – Powers precision instruments requiring temperature stability, diagnostics, and communication.
-
Calibration Laboratories – Supplies power to calibration equipment with diagnostic monitoring.
-
High‑Precision Measurement Systems – Powers vibration analysis and other critical measurement systems.
-
Safety‑Related Systems – SIL 2 certification makes it suitable for safety‑critical applications.
-
System Integration Projects – Used when communication and diagnostic reporting are required.
Competitive Comparison
| Aspect | DS3800NTCF (GE) | DS3800NTCD1A1A (GE) | DS3800NPTA1E1B (GE) |
|---|---|---|---|
| +5V Output | 8A | 5A | 8A |
| ±15V Output | 2A each | 1A each | 2A each |
| Temperature Coefficient | < 30 ppm/°C | < 50 ppm/°C | < 30 ppm/°C |
| Communication | RS‑485 + Ethernet | RS‑485 only | No |
| Predictive Analytics | Yes | No | No |
| SIL 2 | Yes | No | No |
| Price (refurb) | ~$5,500–$8,000 | ~$3,800–$5,500 | ~$3,800–$5,200 |
Selection Guidelines & Precautions
-
Application Verification – Designed for precision instrumentation with communication, diagnostics, and SIL 2.
-
Physical Compatibility – 6HP wide, requires 1.5 adjacent slots.
-
Backplane Compatibility – Uses P1 and P2. If backplane lacks P2, communication features unavailable.
-
Communication Configuration – Configure RS‑485/Modbus and Ethernet/Modbus TCP parameters via backplane communication using GE Service Tool Software.
-
Temperature Compensation – Requires 30‑minute warm‑up to achieve specified temperature coefficient.
-
Thermal Derating – Full output to 55°C; derate to 90% at 55–60°C, 80% at 60–65°C. Do not operate above 65°C.
-
SIL 2 Compliance – Follow GE safety manual GEI‑101085 for installation and proof‑test intervals.
-
Spare Sourcing – Production ended in 2021. Request test report verifying outputs, communication functions, diagnostic functions, predictive analytics, and temperature stability. Inspect for capacitor bulging or discoloration.

A-B 1756-N2
IXYS VUO35-12N07
ABB ACS-CP-C


Reviews