Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 100–150 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 10A (main logic), ±15 VDC / 2A (each rail, analog circuits) |
| Isolation | Full isolation (1.5kV input‑to‑output, 2.0kV output‑to‑ground) |
| Protection | Overcurrent protection (adjustable per output via jumpers), short‑circuit protection, transient suppression (4kV), reverse polarity protection, input undervoltage lockout |
| Regulation | Load regulation: ±0.3%; Line regulation: ±0.15%; Ripple: < 20mVpp (+5V), < 15mVpp (±15V) |
| Power Quality Monitoring | Onboard power quality analysis engine for monitoring voltage sag, surge, harmonics, and transient events; event logging (2,000‑event buffer) |
| Monitoring | 6 analog feedback channels (voltage and current monitoring for each output rail, plus input monitoring); 4 digital fault outputs (relay, 24V/1A) for system faults and power quality alarms |
| Digital Interface | 4 digital inputs for external control; 6 digital outputs for system status indication |
| Operating Temperature | –25°C to +60°C |
| Form Factor | 6U × 6HP (30mm) – requires 1.5 slots |
| Backplane Connector | Standard VME 96‑pin P1 + reinforced 60‑pin P2 |
| Status LEDs | 8 indicators: +5V OK (green), +15V OK (green), –15V OK (green), SYSTEM OK (green), FAULT (red), COMM ACTIVE (white), POWER QUALITY ALERT (orange), TRANSIENT DETECTED (red flash) |
| Certifications | CE, UL 508, CSA Class I Div 2 |
| Efficiency | ~84% at full load |
Critical note: The DS3800NSQE is a supervisory control and power quality enhancement interface. It is physically wider (6HP) than standard 4HP boards and requires 1.5 adjacent slots. Hot‑swapping is not supported.
Key Features & Advantages
-
Power Quality Monitoring – Onboard analysis engine for voltage sag, surge, harmonics, and transient events.
-
Event Logging – 2,000‑event buffer for power quality events.
-
Supervisory Control – Onboard microcontroller for diagnostic reporting and system health monitoring.
-
Comprehensive Monitoring – Six analog channels provide V+I monitoring for each output plus input.
-
Four Fault Relays – Separate fault indication for system faults and power quality alarms.
-
Full Isolation – 1.5kV isolation protects sensitive circuits.
Typical Application Cases
-
Main Control Cabinets – Provides power with integrated power quality monitoring.
-
Advanced I/O Racks – Powers racks requiring power quality analysis.
-
System Integration Projects – Used when power quality reporting is required for critical systems.
Selection Guidelines & Precautions
-
Application Verification – Designed for integrated power management with power quality monitoring.
-
Physical Compatibility – 6HP wide, requires 1.5 adjacent slots.
-
Backplane Compatibility – Uses P1 and P2. If backplane lacks P2, power quality features unavailable.
-
Thermal Derating – Full output to 50°C; derate to 90% at 50–55°C, 80% at 55–60°C.
-
Spare Sourcing – Production ended in 2010. Request test report verifying outputs and power quality functions. Inspect for capacitor bulging or discoloration.

SCHNEIDER LC1D50M7C
п FW000
п FW221


Reviews
There are no reviews yet.