Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 100–150 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 15A (controller logic), ±15 VDC / 3A (each rail, analog circuits) |
| Isolation | Full isolation (1.5kV input‑to‑output, 2.0kV output‑to‑ground) |
| Protection | Overcurrent protection (adjustable), short‑circuit protection, transient suppression (4kV), reverse polarity protection, input undervoltage lockout |
| Regulation | Load regulation: ±0.2%; Line regulation: ±0.1%; Ripple: < 20mVpp (+5V), < 15mVpp (±15V) |
| Redundancy Features | Active load sharing with redundant controller interfaces; automatic failover detection and reporting; diagnostic heartbeat for each output rail |
| Monitoring | 6 analog feedback channels (voltage and current monitoring for each output rail); 4 digital fault outputs (relay, 24V/1A) for individual output faults, input status, and system health |
| Digital Interface | 2 digital inputs for controller status; 4 digital outputs for system status indication |
| Supervisory Control | Onboard microcontroller for redundancy management, load sharing coordination, and diagnostic reporting; communicates with main CPU via backplane |
| Operating Temperature | –30°C to +65°C |
| Form Factor | 6U × 6HP (30mm) – requires 1.5 slots |
| Backplane Connector | Standard VME 96‑pin P1 + reinforced 60‑pin P2 (for additional I/O and high‑current outputs) |
| Status LEDs | 8 indicators: +5V OK (green), +15V OK (green), –15V OK (green), SYSTEM OK (green), FAULT (red), REDUNDANCY ACTIVE (amber), LOAD SHARE ACTIVE (blue), COMM ACTIVE (white) |
| Certifications | CE, UL 508, CSA Class I Div 2 |
| Efficiency | ~85% at full load |
Critical note: The DS3800NRCA is a redundant controller power interface designed for high‑availability control systems. It integrates load sharing, fault detection, and supervisory control for redundant controller configurations. This board is physically wider (6HP) than standard 4HP boards and requires 1.5 adjacent slots. Hot‑swapping is not supported.
Key Features & Advantages
-
Redundant Controller Interface – The DS3800NRCA is designed to interface with redundant controller configurations, providing power to multiple CPU boards and coordinating load sharing for maximum availability.
-
Active Load Sharing – The onboard microcontroller manages active load sharing between redundant power sources, ensuring balanced power distribution and preventing overloading of individual supplies.
-
Comprehensive Monitoring – Six analog feedback channels provide voltage and current telemetry for all output rails, enabling detailed power health monitoring and load analysis.
-
Supervisory Control – The onboard microcontroller performs redundancy management, fault detection, diagnostic reporting, and heartbeat monitoring for each output rail.
-
Multi‑Function Digital I/O – Two digital inputs for controller status; four digital outputs provide system status indication and external alarm signaling.
-
Four Fault Relays – Four form‑C relay contacts (24V/1A) provide separate fault indication for each output rail and system health, enabling flexible alarm configuration.
-
Diagnostic Heartbeat – Each output rail includes a diagnostic heartbeat signal that the main CPU can monitor to detect power supply anomalies.
-
Full Isolation – 1.5kV isolation protects sensitive circuits from ground loops and transients.
-
Wide Temperature Range – Extended –30°C to +65°C range and CSA Div 2 certification make the DS3800NRCA suitable for demanding environments.
Typical Application Cases
-
Redundant Mark IV/V Control Cabinets – Installed in main racks where redundant controllers require coordinated power distribution and monitoring.
-
High‑Availability Turbine Control Systems – Provides power and supervisory control for critical turbine control applications requiring maximum availability.
-
Frame 9E Gas Turbine Main Racks – Supports redundant controller configurations in large gas turbines.
-
Safety‑Related Systems – Powers redundant safety shutdown systems where power continuity is critical.
-
System Integration Projects – Used when integrating redundant power architectures with plant DCS.
Competitive Comparison
| Aspect | DS3800NRCA (GE) | DS3800NPSR1B1B (GE) | DS3800NPSY1E1D (GE) |
|---|---|---|---|
| Redundancy Management | Yes (active load sharing) | Yes (failover only) | No |
| Supervisory Control | Yes | No | Yes |
| +5V Output | 15A | 15A | 15A |
| Monitoring Channels | 6 (V + I) | 4 (V + I) | 6 (V + I) |
| Fault Relays | 4 | 2 | 3 |
| Diagnostic Heartbeat | Yes | No | No |
| Digital I/O | 2 DI + 4 DO | 2 DI + 2 DO | 4 DI + 6 DO |
| Form Factor | 6HP (1.5 slots) | 6HP (1.5 slots) | 6HP (1.5 slots) |
| Price (refurb) | ~$5,000–$7,000 | ~$4,500–$6,500 | ~$5,500–$7,800 |
The DS3800NRCA is the premier redundant controller power interface in the DS3800 family, offering active load sharing, supervisory control, and comprehensive monitoring for high‑availability systems.
Selection Guidelines & Precautions
-
Application Verification – The DS3800NRCA is designed for redundant controller applications requiring active load sharing and supervisory control. If your application does not require redundancy management, simpler boards (NPSJ, NPSR) may be more cost‑effective.
-
Physical Compatibility – The DS3800NRCA is 6HP wide, requiring 1.5 adjacent slots in your Mark IV/V rack. It will not fit in standard 4HP slots.
-
Backplane Compatibility – Uses both P1 and reinforced P2 connectors. Additional digital I/O and supervisory communication are provided through the P2 connector. If your backplane lacks P2, advanced features will be unavailable.
-
Power Budget – Calculate total current draw:
-
+5V: max 15A
-
±15V: max 3A each
Exceeding any output will trigger overcurrent protection.
-
-
Load Sharing Configuration – Configure load sharing parameters via onboard DIP switches (SW1) or backplane communication. Default settings balance load evenly between redundant sources.
-
Grounding for Full Isolation – Use separate returns:
-
IN_GND → Battery negative
-
OUT_GND → Rack logic ground
Using a common ground defeats the isolation barrier.
-
-
Thermal Derating – Full output available up to 55°C:
-
55°C–60°C: derate all outputs to 90% of rated current
-
60°C–65°C: derate all outputs to 80% of rated current
-
Above 65°C: do not operate
-
-
Spare Sourcing – Production ended in 2015. When purchasing refurbished units, request a load test report verifying all outputs at rated current, plus functional verification of load sharing, supervisory control, and diagnostic heartbeat at 25°C and 55°C. Visually inspect for capacitor bulging, discoloration, or burned traces. The DS3800NRCA is the premier redundant controller power solution—prioritize this for high‑availability applications requiring active load sharing and supervisory control.

SIEMENS 6ES7-972-0BA12-0XA0
GE IC694TBB032
SCHNEIDER 140XTS00200


Reviews