Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | Two independent 125 VDC inputs (range 100–150 VDC each); 24 VDC compatible with external adapters |
| Input Redundancy | Automatic failover with diode‑ORing; input priority selection via onboard jumpers (primary/secondary) |
| Output Rails | +5 VDC / 15A, ±15 VDC / 3A (each rail) |
| Isolation | Full isolation (1.5kV input‑to‑output, 2.0kV output‑to‑ground) |
| Protection | Overcurrent protection (fixed), short‑circuit protection, transient suppression (4kV), reverse polarity protection, input undervoltage lockout (each input independently monitored) |
| Monitoring | 4 analog feedback channels (voltage and current monitoring for each output rail); dual digital fault outputs (relay, 24V/1A) for input failover and output fault alarms |
| Digital Interface | 2 digital inputs for input priority selection override; 2 digital outputs for input status indication |
| Operating Temperature | –30°C to +65°C |
| Form Factor | 6U × 6HP (30mm) – requires 1.5 slots |
| Backplane Connector | Standard VME 96‑pin P1 + reinforced 60‑pin P2 (for second DC input and high‑current outputs) |
| Status LEDs | 8 indicators: INPUT 1 OK (green), INPUT 2 OK (green), OUTPUT OK (green), OVP (red), OCP (red), TEMP (yellow), FAILOVER ACTIVE (amber), ISO OK (blue) |
| Certifications | CE, UL 508, CSA Class I Div 2 |
| Efficiency | ~86% at full load |
Critical note: The DS3800NPSR is a redundant power board designed for high‑availability applications requiring dual input failover. It is physically wider (6HP) than standard 4HP boards and requires 1.5 adjacent slots. This board does not support hot‑swapping.
Key Features & Advantages
-
Dual Input Redundancy – The DS3800NPSR accepts two independent 125VDC inputs (e.g., separate battery banks or rectifier feeds). Automatic failover occurs within < 5ms on input loss, ensuring uninterrupted power to critical control circuits.
-
Input Priority Selection – Onboard jumpers allow configuration of primary and secondary inputs. The board will draw from the primary input when available and automatically switch to the secondary on primary failure. The second digital input allows remote override of priority selection.
-
Quad Monitoring Channels – Four analog feedback channels provide voltage and current telemetry for +5V and ±15V outputs, enabling comprehensive remote monitoring of power health and load conditions.
-
Dual Fault Relays – Two form‑C relay contacts (24V/1A) provide separate fault indication for input failover events and output fault conditions, enabling integration with plant DCS for alarm and status reporting.
-
Full Isolation – 1.5kV isolation protects sensitive circuits from ground loops and transients on either input source.
-
Wide Temperature Range – Extended –30°C to +65°C range and CSA Div 2 certification make the DS3800NPSR suitable for demanding environments.
-
Input Status Indication – Two digital outputs provide active status indication for each input, allowing remote monitoring of which input is currently supplying power.
-
Proven Reliability – The DS3800NPSR is widely used in critical turbine applications where power loss is not an option.
Typical Application Cases
-
Critical Main Control Cabinets – Installed in main racks where power continuity is essential, such as turbine control, overspeed protection, and safety shutdown systems.
-
Redundant I/O Racks – Powers I/O racks requiring high availability for critical process monitoring and control.
-
Frame 9E Gas Turbine Main Racks – Provides redundant power to high‑reliability control systems in large gas turbines.
-
Offshore Platforms with Dual Battery Banks – The DS3800NPSR allows connection to two independent battery banks, ensuring power continuity during battery maintenance or fault conditions.
-
Safety Shutdown Systems – Supplies power to emergency trip systems where power loss must be avoided at all costs.
Competitive Comparison
| Aspect | DS3800NPSR (GE) | DS3800NPSJ1B1C (GE) | Generic Redundant Power Supply |
|---|---|---|---|
| Input Redundancy | Yes (dual inputs, auto failover) | No (single input) | Yes (dual inputs) |
| +5V Output | 15A | 22A | Varies |
| ±15V Output | 3A each | 4.5A each | Varies |
| Isolation | Full (1.5kV) | Full (1.5kV) | Varies |
| Feedback Channels | 4 (voltage + current) | 4 (voltage only) | Varies |
| Fault Relays | 2 (form‑C) | None | Often 1 |
| Digital I/O | 2 DI + 2 DO | 2 DO + 1 DI | Varies |
| Form Factor | 6HP (1.5 slots) | 8HP (2 slots) | Standalone DIN‑rail |
| Efficiency | ~86% | ~88% | ~85–90% |
| Price (refurb) | ~$4,500–$6,500 | ~$5,500–$7,500 | ~$1,000–$2,000 |
The DS3800NPSR is the premier redundant power solution for Mark IV/V systems, offering dual input failover and comprehensive monitoring in a compact 6HP form factor.
Selection Guidelines & Precautions
-
Application Verification – The DS3800NPSR is designed for high‑availability applications requiring dual input failover. If your application does not require redundancy, NPSJ or NPSE boards are more cost‑effective.
-
Physical Compatibility – The DS3800NPSR is 6HP wide, requiring 1.5 adjacent slots in your Mark IV/V rack. It will not fit in standard 4HP slots and requires an adjacent empty half‑slot position.
-
Backplane Compatibility – Uses both P1 and reinforced P2 connectors. The second DC input is provided through the P2 connector. If your backplane lacks P2 (pre‑2005 racks), the redundant input feature will be unavailable.
-
Input Configuration – Connect both DC inputs to independent sources (e.g., separate battery banks). Configure primary/secondary priority via onboard jumpers (JP1‑JP2). The secondary input serves as the backup source.
-
Grounding for Full Isolation – Use separate returns:
-
IN1_GND → Battery 1 negative
-
IN2_GND → Battery 2 negative
-
OUT_GND → Rack logic ground
Using a common ground for all defeats the isolation barrier and the purpose of redundancy.
-
-
Thermal Derating – Full output available up to 55°C:
-
55°C–60°C: derate all outputs to 90% of rated current
-
60°C–65°C: derate all outputs to 80% of rated current
-
Above 65°C: do not operate
-
-
Compatibility – The DS3800NPSR is pin‑compatible with Mark IV backplanes supporting 6HP boards and P2 connectors. No backplane modifications are required if these conditions are met.
-
Spare Sourcing – Production ended in 2015. When purchasing refurbished units, request a load test report verifying both inputs and failover functionality at 25°C and 55°C. Visually inspect for capacitor bulging, discoloration, or burned traces. The DS3800NPSR is the preferred choice for high‑availability turbine control applications—prioritize this over single‑input boards when redundancy is required.

ABB 3HAC044075-001/01
A-B 1756-BA2
ABB 3HAC044075-001
GE IC200CHS022