Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 95–155 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 10A (peak 13A for 3s), ±15 VDC / 1.5A (each rail, peak 2.0A for 5s) |
| Isolation | Non-isolated (common-ground design) |
| Analog Feedback | 1 single-ended analog input (0–10V) for basic power health monitoring |
| Operating Temperature | –40°C to +70°C |
| Form Factor | 6U × 4HP (20mm), standard VME 96-pin connector |
| Status LEDs | 3 indicators: PWR OK (green), OVP (red), TEMP (yellow) |
| Certifications | CE, UL 508, CSA Class I Div 2 |
| Efficiency | ~84% at full load |
Critical note: The DS3800NPSE1C1E is functionally identical to the C1C and C1D. The revision letter “E” reflects final component substitutions and PCB artwork updates to ensure continued production through GE’s final manufacturing run. Performance specifications remain unchanged.
Key Features & Advantages
-
Last Production Revision – The DS3800NPSE1C1E incorporates all cumulative field fixes from previous C-series revisions and represents the most mature, bug-free version of this board.
-
Optimized PCB Layout – Revised trace routing reduces electromagnetic interference (EMI) by approximately 3dB, improving compatibility with sensitive analog cards in densely populated racks.
-
Modern Component Sourcing – Uses the latest-generation MOSFETs and polymer hybrid capacitors from current production lines, ensuring the longest possible remaining shelf life for new-old-stock (NOS) units.
-
Same Long Capacitor Life – Retains polymer hybrid capacitors with 15,000 hours at 70°C lifetime rating.
-
Direct Drop-In Replacement – Pin-compatible with all 4HP non-isolated DS3800 power boards (A1A, C1A, C1B, C1C, C1D)—no firmware, backplane, or wiring changes required.
-
Proven Reliability – No new failure modes identified; the C1E benefits from over a decade of field data across all previous C-series revisions.
Typical Application Cases
-
Final Stocking for Legacy Fleets – Many plants purchase the DS3800NPSE1C1E as their last batch of non-isolated spares, knowing it is the final revision and will support operations for the remaining life of their Mark IV systems.
-
Direct Replacement for Any Failed Non-Isolated Board – When an A1A, C1A, C1B, C1C, or C1D fails, the DS3800NPSE1C1E is the preferred replacement due to its mature design and component availability.
-
Cold-Climate Outdoor Cabinets – Retains –40°C low-temperature capability for unheated enclosures.
-
Steam Turbine Electro-Hydraulic Controls – Supplies ±15V to servo valve drivers in smaller installations.
-
Test Benches and Simulators – Used in laboratory environments where long-term reliability is valued over advanced diagnostics.
Competitive Comparison
| Aspect | DS3800NPSE1C1E (GE) | DS3800NPSE1C1D (GE) | DS3800NPSE1B1B (GE) |
|---|---|---|---|
| +5V Output | 10A (13A peak) | 10A (13A peak) | 20A (22A peak) |
| ±15V Output | 1.5A (2.0A peak) | 1.5A (2.0A peak) | 3.0A |
| Capacitor Technology | Polymer hybrid (15,000h @70°C) | Polymer hybrid (15,000h @70°C) | Polymer hybrid (12,000h @75°C) |
| Output Ripple (+5V) | < 20mVpp | < 20mVpp | < 15mVpp |
| Operating Temp | –40°C to +70°C | –40°C to +70°C | –40°C to +75°C |
| PCB Revision | Most mature (final layout) | Previous layout | Different design |
| EMI Performance | Best in C-series (3dB improvement) | Standard | Standard |
| Component Availability | Best (latest production components) | Good (some parts obsolete) | Limited (many parts obsolete) |
| Isolation | None | None | Full |
| Diagnostics | LEDs only | LEDs only | Ethernet + logging |
| Price (refurb) | ~$2,700–$3,700 | ~$2,500–$3,500 | ~$4,000–$6,000 |
The DS3800NPSE1C1E is the ultimate non-isolated power board for Mark IV/V systems, offering the most mature design and best component availability, but it remains functionally limited compared to the fully isolated B1B.
Selection Guidelines & Precautions
-
Power Budget Verification – Calculate total +5V current draw. If it exceeds 10A (or 9A above 60°C), choose the B1B instead. Overloading triggers OVP and latches the output off.
-
Grounding Requirements – As a non-isolated board, the DS3800NPSE1C1E demands a single-point ground (< 1Ω) for the entire cabinet. Mixing with isolated power supplies creates ground loops that degrade analog signals and may damage TVS diodes.
-
No Diagnostics – Lacks predictive failure analytics. Perform manual ESR checks on primary capacitors every 6 months. Replace the board if ESR exceeds 2× initial value—capacitor-only replacement is not recommended.
-
Thermal Derating – Full 10A output available up to 60°C:
-
60°C – 65°C: derate +5V to 9A
-
65°C – 70°C: derate +5V to 8A
-
Above 70°C: do not operate
-
-
Compatibility – The DS3800NPSE1C1E is pin-compatible with all Mark IV backplanes. When replacing a B1B, the missing isolated feedback channels may cause the CPU board to report power health errors—consult your GE manual to disable additional channel monitoring in firmware.
-
PCB Differences – While functionally identical, the DS3800NPSE1C1E has slightly different trace routing. This does not affect performance but means that replacement capacitors may have different physical footprints. If you are a repair facility, update your rework procedures accordingly—the new layout places C8 and C12 slightly closer to the edge connector.
-
Spare Sourcing – Production ended in 2022. When purchasing refurbished units, request a load test report verifying output ripple < 20mVpp at 25°C and < 40mVpp at 60°C. Prefer units with documented operating hours (< 5,000 hours) and a component traceability report. Since the C1E is the final revision, any unit with a revision label older than “E” should be considered less mature—prioritize “E” boards when available. Visually inspect for capacitor bulging, transformer discoloration, or repaired traces.

A-B 1784-SD1
Siemens 6ES7131-4BF00-0AA0
SCHNEIDER VCF5= V5+ KCF3PZ


Reviews