Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Input Voltage | 125 VDC nominal (range 95–155 VDC); 24 VDC compatible with external adapter |
| Output Rails | +5 VDC / 10A (peak 13A for 3s), ±15 VDC / 1.5A (each rail, peak 2.0A for 5s) |
| Isolation | Non-isolated (common-ground design) |
| Analog Feedback | 1 single-ended analog input (0–10V) for basic power health monitoring |
| Operating Temperature | –40°C to +70°C |
| Form Factor | 6U × 4HP (20mm), standard VME 96-pin connector |
| Status LEDs | 3 indicators: PWR OK (green), OVP (red), TEMP (yellow) |
| Certifications | CE, UL 508, CSA Class I Div 2 |
| Efficiency | ~84% at full load |
Critical note: The DS3800NPSE1C1D is functionally identical to the C1C. The revision letter “D” primarily reflects alternative component suppliers (e.g., different capacitor brands, MOSFET part numbers) to mitigate obsolescence. Performance specifications remain unchanged.
Key Features & Advantages
-
Supply Chain Stabilization – The DS3800NPSE1C1D uses currently available components, ensuring consistent availability for refurbishers and plant maintenance teams, unlike earlier revisions with hard-to-find parts.
-
Equivalent Performance to C1C – All electrical characteristics (ripple, regulation, efficiency, transient response) match the C1C within measurement tolerance.
-
Direct Drop-In Replacement – Pin-compatible with C1C, C1B, C1A, and A1A—no firmware, backplane, or wiring changes required.
-
Same Long Capacitor Life – Retains polymer hybrid capacitors with 15,000 hours at 70°C lifetime rating.
-
CSA Class I Div 2 Certified – Suitable for hazardous locations, unchanged from C1C.
-
Proven Reliability – Incorporates all field fixes from previous C-series revisions, with no new known failure modes identified.
Typical Application Cases
-
Direct Replacement for Failed C1C/C1B Units – When a C1C is unavailable, the DS3800NPSE1C1D serves as the preferred substitute with identical form, fit, and function.
-
Legacy Mark IV Auxiliary Racks – Powers low-density I/O cards in non-critical monitoring and control loops.
-
Cold-Climate Outdoor Cabinets – Retains –40°C low-temperature capability for unheated enclosures.
-
Steam Turbine Electro-Hydraulic Controls – Supplies ±15V to servo valve drivers in smaller installations.
-
Fleet Standardization – Many utilities now specify the DS3800NPSE1C1D as the sole non-isolated spare to simplify logistics, knowing it can replace all earlier C-series variants.
Competitive Comparison
| Aspect | DS3800NPSE1C1D (GE) | DS3800NPSE1C1C (GE) | DS3800NPSE1B1B (GE) |
|---|---|---|---|
| +5V Output | 10A (13A peak) | 10A (13A peak) | 20A (22A peak) |
| ±15V Output | 1.5A (2.0A peak) | 1.5A (2.0A peak) | 3.0A |
| Capacitor Technology | Polymer hybrid (15,000h @70°C) | Polymer hybrid (15,000h @70°C) | Polymer hybrid (12,000h @75°C) |
| Output Ripple (+5V) | < 20mVpp | < 20mVpp | < 15mVpp |
| Operating Temp | –40°C to +70°C | –40°C to +70°C | –40°C to +75°C |
| CSA Div 2 | Yes | Yes | Yes |
| Component Availability | Best (current production components) | Good (some parts obsolete) | Limited (many parts obsolete) |
| Isolation | None | None | Full |
| Diagnostics | LEDs only | LEDs only | Ethernet + logging |
| Price (refurb) | ~$2,500–$3,500 | ~$2,500–$3,500 | ~$4,000–$6,000 |
The DS3800NPSE1C1D offers no functional advantage over the C1C but provides better long-term availability due to modernized component selection. For plants planning extended operations, this revision is the most future-proof choice among non-isolated boards.
Selection Guidelines & Precautions
-
Power Budget Verification – Calculate total +5V current draw. If it exceeds 10A (or 9A above 60°C), choose the B1B instead. Overloading triggers OVP and latches the output off.
-
Grounding Requirements – As a non-isolated board, the DS3800NPSE1C1D demands a single-point ground (< 1Ω) for the entire cabinet. Mixing with isolated power supplies creates ground loops that degrade analog signals and may damage TVS diodes.
-
No Diagnostics – Lacks predictive failure analytics. Perform manual ESR checks on primary capacitors every 6 months. Replace the board if ESR exceeds 2× initial value—capacitor-only replacement is not recommended.
-
Thermal Derating – Full 10A output available up to 60°C:
-
60°C – 65°C: derate +5V to 9A
-
65°C – 70°C: derate +5V to 8A
-
Above 70°C: do not operate
-
-
Compatibility – The DS3800NPSE1C1D is pin-compatible with all Mark IV backplanes. When replacing a B1B, the missing isolated feedback channels may cause the CPU board to report power health errors—consult your GE manual to disable additional channel monitoring in firmware.
-
Component Differences – While the DS3800NPSE1C1D is functionally equivalent to the C1C, it may use different capacitor brands (e.g., Rubycon instead of Panasonic) or MOSFET part numbers. These substitutions are GE-approved and do not affect performance. However, if you are using the board in a SIL-related application, verify that the alternative components maintain the same MTBF ratings—request the component deviation list from your supplier.
-
Spare Sourcing – Production ended in 2021. When purchasing refurbished units, request a load test report verifying output ripple < 20mVpp at 25°C and < 40mVpp at 60°C. Prefer units with documented operating hours (< 5,000 hours) and a component traceability report confirming that all replaced parts are GE-approved equivalents. Avoid units with visible capacitor bulging, transformer discoloration, or repaired PCB traces.

SIEMENS 6ES7195-1GA00-0XA0