GE DS3800NPID1F1F

¥999.00

The DS3800NPID1F1F is the ultimate flagship of General Electric’s Mark V series Fan/Exhaust Control boards for solid-state-primary hybrid applications. The suffix “1F1F” indicates Revision F firmware with 24-bit ADC (±0.5°C / ±0.3°C accuracy), extended temperature components (-40°C to +100°C), military-grade vibration tolerance (10g RMS), 4A solid-state outputs8A mechanical relay outputs4 thermocouple input channels8 RTD input channels (12 total temperature channels), 2 tachometer inputspredictive relay maintenancepredictive thermal modelingredundant backplane communication pathsself-healing diagnosticscyber-hardening (AES-256 encryption), and a 1000-event fault log.

The “F” suffix introduces redundant backplane communicationself-healing diagnostics, and cyber-hardening, while the “1F” variant adds expanded fault logging and dual-redundant backplane paths.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NPID1F1F
Power Supply +5V DC @ 6.5A, +15V DC @ 1.8A, -15V DC @ 1.5A
Temperature Inputs 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
SS Outputs 8 solid-state relays, 4A continuous @ 24–48VDC with individual current monitoring
Relay Outputs 4 mechanical relays, 8A continuous @ 115VAC/30VDC (surge 15A) with predictive maintenance
Tachometer Inputs 2 channels (up to 15 kHz)
Communication Dual-redundant backplane paths with AES-256 encryption
Operating Temperature -40°C to +100°C
Vibration Resistance 10g RMS (extended MIL-STD-810G)
Fault Log 1000 events
LED Indicators Power, SS Run (8x green), SS Overcurrent (flashing red), Relay Run (4x amber), Tach Fail (red x2), RTD Fault (yellow), Relay Degradation (orange), Predictive Model Active (blue), Redundant Path Active, Self-Heal Active, Secure Comms Active, Model Learning (flashing blue), Backplane Active, Bus Fault

Advantages and Distinctive Features

  • 4A Solid-State Outputs with Current Monitoring: Highest SS current with overcurrent detection.

  • 8A Mechanical Relays with Predictive Maintenance: Higher current capacity with real-time contact resistance monitoring.

  • Redundant Backplane Communication: Dual paths with automatic failover (<50ms) and AES-256 encryption.

  • Self-Healing Diagnostics: Automatic relay/SS reset after transient faults (up to 3 resets/24hrs).

  • 1000-Event Fault Log: Expanded diagnostic memory.

  • Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total temperature channels.

  • Predictive Thermal Modeling: Learns cabinet thermal response during 24-hour initial period.

  • RTD Fault Detection: Open/short/lead-wire degradation monitoring.

  • Extended +100°C Operation: Surpasses all standard limits.

  • 10g Vibration Tolerance: Double the standard military-grade rating.


Typical Application Fields

  • Mission-Critical Fan-Dense Mixed Fan Systems: Where redundant communication, self-healing, and cyber-security are required.

  • High-Power Fan Applications: 8A relay capacity for larger auxiliary loads.

  • RTD-Heavy Cabinets: Where RTD sensors are preferred.

  • Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.

  • Desert Power Plants: 100°C upper limit.

  • Nuclear Auxiliary Turbines: High reliability with redundant communication and self-healing.


Comparison with Related Models

Feature DS3800NPID1F1F DS3800NPID1D1E DS3800NPDA1B1B DS3800NOAA1F1D
SS Outputs 8 × 4A 8 × 3A 8 × 3A 8 × 3A
SS Current Monitoring Yes Yes No Yes
Relay Outputs 4 × 8A 4 × 5A 4 × 5A 4 × 5A
Relay Predictive Maintenance Yes Yes No Yes
T/C + RTD Inputs 4 + 8 = 12 4 + 0 = 4 8 + 0 = 8 4 + 8 = 12
Redundant Comms Yes No No Yes
Self-Healing Yes No No Yes
Cyber-Hardening Yes No No Yes
Fault Log 1000 events 500 events Basic 500 events
Operating Temp -40°C to +100°C -40°C to +85°C -20°C to +65°C -40°C to +85°C
Vibration 10g RMS 5g RMS 2g RMS 5g RMS
Cost Ultra-Premium++++ Ultra-Premium High Ultra-Premium

Selection Recommendations

  • Choose the DS3800NPID1F1F if:

    • You need the highest hybrid output (4A SS + 8A relays) with current monitoring .

    • You require redundant backplane communicationself-healing, and cyber-hardening .

    • You require 1000-event fault logging .

    • You require both thermocouple and RTD inputs (12 total channels).

    • You require tachometer feedback .

    • You want predictive thermal modeling and predictive relay maintenance .

    • Your installation operates in extreme environments (-40°C to +100°C) with high vibration.

  • Choose the DS3800NPID1D1E if: You need 3A SS and 5A relays with 500-event logging without redundant comms or cyber-hardening.

  • Choose the DS3800NOAA1F1D if: You need 3A SS and 5A relays with RTD support and redundant comms.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive .

  • SS Overcurrent: If output exceeds 4.5A, LED flashes red—persistent overcurrent triggers bus fault.

  • SS Voltage Limit: Do not exceed 48VDC.

  • High-Voltage/Current Hazard (Relay): Relay outputs switch 115VAC/8A—lethal. Use proper insulation.

  • Relay Inductive Derating: For inductive loads, derate from 8A to 6A .

  • RTD Wiring: Use 3-wire Pt100 RTDs.

  • Redundant Paths: Both backplane paths must be connected for full fault tolerance.

  • Cyber-Hardening: AES-256 encryption must be enabled via Mark V software.

  • Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • CPU Compatibility: Requires Mark V CPU firmware v6.5 or higher for full features.

  • Power Supply: Draws 6.5A on +5V rail—power supply upgrade is mandatory.

FANUC A06B-0117-B855#0049 ά
GE IC693ACC307
A-B 1747-SDN

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NPID1F1F”

Your email address will not be published. Required fields are marked *

Post comment