GE DS3800NPCM1B1B

¥999.00

The DS3800NPCM1B1B is a revision of General Electric’s Mark V series Fan/Exhaust Control board, designed for standard-voltage AC/DC applications with a solid-state-primary hybrid output configuration and dual temperature sensor support. The suffix “1B1B” indicates Revision B firmware with enhanced 16-bit ADC (±1°C / ±0.5°C accuracy), extended temperature components (-20°C to +65°C), 3A solid-state outputs5A mechanical relay outputs8 thermocouple input channels8 RTD input channels (16 total temperature channels), and 2 tachometer input channels.

The DS3800NPCM1B1B is a direct upgrade from the base model, offering improved temperature accuracy (16-bit vs. 12-bit ADC), extended temperature range (-20°C to +65°C), and Revision B firmware enhancements.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NPCM1B1B
Power Supply +5V DC @ 5.0A, +15V DC @ 1.0A, -15V DC @ 0.8A
Temperature Inputs 8 thermocouple + 8 RTD = 16 total channels (16-bit ADC, ±1°C / ±0.5°C)
SS Outputs 8 solid-state relays, 3A continuous @ 24–48VDC
Relay Outputs 4 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A)
Tachometer Inputs 2 channels (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature -20°C to +65°C
LED Indicators Power, SS Run (8x green), Relay Run (4x amber), Tach Fail (red x2), RTD Fault (yellow), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • Dual Temperature Sensor Support (T/C + RTD): 8 thermocouple + 8 RTD inputs (16 total channels)—supports mixed sensor types or redundant monitoring.

  • Improved Temperature Accuracy (16-bit ADC): ±1°C for thermocouples, ±0.5°C for RTDs—double the precision of the base 12-bit (±2°C / ±0.5°C) model.

  • Extended Temperature Range: -20°C to +65°C supports moderately harsh environments.

  • Enhanced Cold-Junction Compensation (Revision B): Improved temperature measurement reliability.

  • Solid-State-Primary Hybrid + Tachometer Feedback: 8 solid-state DC outputs (3A) + 4 high-current relays (5A) + 2 tachometer inputs on a single board.

  • RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.

  • Silent, Maintenance-Free Solid-State Outputs: Unlimited cycle life for DC fans.

  • Relay Auxiliary Outputs: 2500V galvanic isolation for AC/DC auxiliary loads.


Typical Application Fields

  • Safety-Critical Mixed Fan Systems: Where redundant temperature sensing and fan failure detection are mandatory.

  • Mixed Fan Cabinets: Where larger DC fans, high-power AC/DC auxiliary devices, and both T/C and RTD sensors coexist.

  • Unheated Shelters & Outdoor Enclosures: -20°C to +65°C range.

  • Moderately Harsh Environments: Where climate control is limited.


Comparison with Related Models

Feature DS3800NPCM1B1B DS3800NPCM (Base) DS3800NPCF DS3800NOAA1F1D
SS Outputs 8 × 3A 8 × 3A 8 × 3A 8 × 3A
Relay Outputs 4 × 5A 4 × 5A 4 × 5A 4 × 5A
T/C + RTD Inputs 8 + 8 = 16 8 + 8 = 16 8 + 0 = 8 4 + 8 = 12
ADC Resolution 16-bit (±1°C / ±0.5°C) 12-bit (±2°C / ±0.5°C) 12-bit (±2°C) 24-bit (±0.5°C / ±0.3°C)
Operating Temp -20°C to +65°C 0°C to +60°C 0°C to +60°C -40°C to +85°C
Predictive Maintenance No No No Yes
Firmware B A/B A/B F
Cost High High Medium-High Ultra-Premium

Selection Recommendations

  • Choose the DS3800NPCM1B1B if:

    • You need 8 solid-state DC outputs (3A) for larger main fans.

    • You also need 4 high-current mechanical relay outputs (5A) for auxiliary devices.

    • You require both thermocouple and RTD inputs (16 total channels).

    • You require RTD fault detection for sensor integrity monitoring.

    • You require tachometer feedback for fan speed verification.

    • You want improved temperature accuracy (±1°C / ±0.5°C).

    • Your installation requires extended temperature range (-20°C to +65°C).

  • Choose the DS3800NOAA1F1D if: You need 24-bit ADC, predictive maintenance, redundant communication, and extreme temperature range (-40°C to +85°C).

  • Choose the DS3800NPCF if: You need the same outputs but only require thermocouple inputs (no RTDs).


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • SS Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.

  • SS Current Limitation: Rated at 3A continuous. Verify fan current does not exceed this limit.

  • High-Voltage/Current Hazard (Relay): Relay outputs switch 115VAC/5A—lethal. Use proper insulation.

  • Relay Inductive Derating: For inductive loads, derate from 5A to 3.5A or use RC snubbers.

  • RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.

  • RTD Lead Resistance: Use wire with resistance ≤10Ω per lead for accurate measurements.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal—not at the fan end.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—tachometer monitoring and RTD fault detection disabled in fallback mode.

  • Firmware Compatibility: Revision B firmware is compatible with Mark V CPU firmware v4.0 and above. For v3.x, the enhanced ADC features and RTD support may be partially disabled—confirm compatibility before purchasing.

ABB 3HAC16831-1
ABB 3HAC16831-1
A-B 1756-BA1

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NPCM1B1B”

Your email address will not be published. Required fields are marked *

Post comment