GE DS3800NPCM

¥999.00

The DS3800NPCM is a Fan/Exhaust Control board from General Electric’s Mark V Speedtronic™ series, designed for standard-voltage AC/DC applications with a solid-state-primary hybrid output configuration. The “NPCM” designation indicates a board with:

  • 8 solid-state outputs (3A @ 24–48VDC) for higher-current DC fan control

  • 4 mechanical relays (5A @ 115VAC / 30VDC) for high-power AC/DC auxiliary control

  • 8 thermocouple input channels for temperature monitoring

  • 8 RTD input channels (Pt100, 3-wire) for high-precision temperature monitoring—adding 16 total temperature channels

  • 2 tachometer input channels for fan speed verification

  • 12-bit ADC (±2°C / ±0.5°C accuracy)

  • Standard temperature range (0°C to +60°C)

The DS3800NPCM is the most comprehensive hybrid board in the Mark V lineup, combining dual-sensor temperature monitoring (T/C + RTD), 3A solid-state outputs, 5A relay auxiliaries, and tachometer feedback on a single board—making it suitable for applications requiring redundant temperature sensing.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NPCM
Power Supply +5V DC @ 5.0A, +15V DC @ 1.0A, -15V DC @ 0.8A
Temperature Inputs 8 thermocouple + 8 RTD = 16 total channels (12-bit ADC, ±2°C / ±0.5°C)
SS Outputs 8 solid-state relays, 3A continuous @ 24–48VDC
Relay Outputs 4 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A)
Tachometer Inputs 2 channels (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, SS Run (8x green), Relay Run (4x amber), Tach Fail (red x2), RTD Fault (yellow), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • Dual Temperature Sensor Support (T/C + RTD): 8 thermocouple + 8 RTD inputs (16 total channels)—supports mixed sensor types or redundant monitoring.

  • Solid-State-Primary Hybrid + Tachometer Feedback: 8 solid-state DC outputs (3A) + 4 high-current relays (5A) + 2 tachometer inputs on a single board.

  • Higher Solid-State Current (3A): Supports larger DC fans compared to 2A boards.

  • Higher Relay Current (5A): Supports larger AC/DC auxiliary loads.

  • RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.

  • Silent, Maintenance-Free Solid-State Outputs: Unlimited cycle life for DC fans.

  • Relay Auxiliary Outputs: 2500V galvanic isolation for AC/DC auxiliary loads.

  • Fan Speed Verification: Tachometer inputs allow CPU to confirm fan operation.

  • Low EMI Emissions: Solid-state outputs minimize interference with sensitive cards.


Typical Application Fields

  • Safety-Critical Mixed Fan Systems: Where redundant temperature sensing and fan failure detection are mandatory.

  • Mixed Fan Cabinets: Where larger DC fans, high-power AC/DC auxiliary devices, and both T/C and RTD sensors coexist.

  • Nuclear Auxiliary Turbines: High reliability with redundant temperature sensing.

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.


Comparison with Related Models

Feature DS3800NPCM DS3800NPCF DS3800NPCE1A1B DS3800NOAA1F1D
SS Outputs 8 × 3A 8 × 3A 8 × 3A 8 × 3A
Relay Outputs 4 × 5A 4 × 5A 4 × 5A 4 × 5A
T/C + RTD Inputs 8 + 8 = 16 8 + 0 = 8 4 + 0 = 4 4 + 8 = 12
Tach Inputs 2 channels 2 channels 2 channels 2 channels
RTD Fault Detection Yes No No Yes
ADC 12-bit 12-bit 12-bit 24-bit (±0.5°C)
Operating Temp 0°C to +60°C 0°C to +60°C -20°C to +65°C -40°C to +85°C
Predictive Maintenance No No No Yes
Cost High Medium-High Medium-High Ultra-Premium

Selection Recommendations

  • Choose the DS3800NPCM if:

    • You need 8 solid-state DC outputs (3A) for larger main fans.

    • You also need 4 high-current mechanical relay outputs (5A) for auxiliary devices.

    • You require both thermocouple and RTD inputs (16 total channels).

    • You require RTD fault detection for sensor integrity monitoring.

    • You require tachometer feedback for fan speed verification.

    • You have a climate-controlled environment (0°C to +60°C).

  • Choose the DS3800NPCF if: You need the same outputs but only require thermocouple inputs (no RTDs).

  • Choose the DS3800NOAA1F1D if: You need 24-bit ADC, predictive maintenance, redundant communication, and extreme temperature range (-40°C to +85°C).


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • SS Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.

  • SS Current Limitation: Rated at 3A continuous. Verify fan current does not exceed this limit.

  • High-Voltage/Current Hazard (Relay): Relay outputs switch 115VAC/5A—lethal. Use proper insulation.

  • Relay Inductive Derating: For inductive loads, derate from 5A to 3.5A or use RC snubbers.

  • RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.

  • RTD Lead Resistance: Use wire with resistance ≤10Ω per lead for accurate measurements.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal—not at the fan end.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—tachometer monitoring and RTD fault detection disabled in fallback mode.

  • Firmware Compatibility: The DS3800NPCM is compatible with Mark V CPU firmware v4.0 and above for full RTD support. For v3.x, RTD inputs may be partially disabled—confirm compatibility before purchasing.

ABB SK829007-B
CONTEC PIO-16/16T PCI H
ABB 3HAC16831-1

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NPCM”