GE DS3800NMEC1D1C

¥999.00

The DS3800NMEC1D1C is a premium revision of General Electric’s Mark V series Fan/Exhaust Control board, designed for standard-voltage AC/DC applications with a hybrid output configuration. The suffix “1D1C” indicates Revision D firmware with 24-bit ADC (±0.5°C accuracy), extended temperature components (-40°C to +75°C), military-grade vibration tolerance (5g RMS), 5A mechanical relay outputs2A solid-state outputs, and 4 thermocouple input channels—with no tachometer feedback. The “1C” suffix also indicates enhanced cold-junction compensation and improved noise filtering compared to the “1B” variant.

The DS3800NMEC1D1C builds upon the “1D1B” variant with Revision D’s enhanced cold-junction compensation and noise filtering, providing more stable temperature readings in electrically noisy environments.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NMEC1D1C
Power Supply +5V DC @ 4.0A, +15V DC @ 0.7A, -15V DC @ 0.5A
Temperature Inputs 4 thermocouple channels (Type J/K/T, 24-bit ADC, ±0.5°C accuracy)
Relay Outputs 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A) with predictive maintenance
SS Outputs 4 solid-state relays, 2A continuous @ 24–48VDC
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature -40°C to +75°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 200 events
LED Indicators Power, Relay Run (8x amber), SS Run (4x green), Over-Temp Alarm, Relay Degradation Warning, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • Hybrid Output Architecture: Combines 8 mechanical relays (5A) with 4 solid-state outputs (2A) on a single board.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C accuracy for precise thermal management.

  • Enhanced Cold-Junction Compensation (Revision D): Improved temperature measurement stability in fluctuating ambient conditions.

  • Enhanced Noise Filtering: Improved ADC input filtering for stable readings in high-EMI environments.

  • Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.

  • Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.

  • 5A Mechanical Relays: Supports larger AC/DC fans.

  • Fan-Dense Design: 8 relay outputs + 4 SS outputs with only 4 temperature inputs.

  • 200-Event Fault Log: Stores temperature alarms and relay degradation events.


Typical Application Fields

  • Fan-Dense Mixed Fan Cabinets: Where both high-power AC/DC fans and low-voltage DC auxiliary fans are present.

  • Offshore Oil & Gas Platforms: Extreme temperature, vibration, and high-EMI environments.

  • Desert Power Plants: 75°C upper limit.

  • Arctic Compressor Stations: -40°C low-temperature tolerance.

  • High-EMI Installations: Where noise filtering provides more stable temperature readings.


Comparison with Related Models

Feature DS3800NMEC1D1C DS3800NMEC1D1B DS3800NMEC1C1B DS3800NMEA1D1G
Relay Outputs 8 × 5A 8 × 5A 8 × 5A 8 × 5A
SS Outputs 4 × 2A 4 × 2A 4 × 2A 4 × 3A
ADC Resolution 24-bit (±0.5°C) 24-bit (±0.5°C) 16-bit (±1°C) 24-bit (±0.5°C)
Enhanced CJC Yes (Rev D) No No Yes (Rev D)
Noise Filtering Yes (Rev D) No No Yes (Rev D)
Predictive Maintenance Yes Yes No Yes
Operating Temp -40°C to +75°C -40°C to +75°C -20°C to +65°C -40°C to +85°C
Fault Log 200 events 200 events Basic 500 events
Firmware D D C D
Cost High High Medium Ultra-Premium

Selection Recommendations

  • Choose the DS3800NMEC1D1C if:

    • You need 5A relay outputs (AC or DC) for main fans.

    • You also need solid-state outputs (24–48VDC) for auxiliary fans or alarms.

    • You want ultra-precise temperature monitoring (±0.5°C).

    • You need enhanced noise filtering for high-EMI environments.

    • You need predictive relay maintenance.

    • Your installation is in extreme environments (-40°C to +75°C) with high vibration.

    • You do not require tachometer feedback.

  • Choose the DS3800NMEC1D1B if: You need the same features but do not require enhanced CJC or noise filtering.

  • Choose the DS3800NMEA1D1G if: You need 8 thermocouple inputs, 3A SS outputs, and +85°C operation.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • High-Voltage/Current Hazard: Relay outputs switch 115VAC/5A—lethal. Use proper insulation.

  • Relay Inductive Derating: For inductive fan motors, derate from 5A to 3.5A or use RC snubbers.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • No Tachometer Inputs: Do not connect speed sensors.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—predictive maintenance disabled in fallback mode.

  • Firmware Compatibility: Revision D firmware requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, enhanced CJC, noise filtering, and predictive maintenance. For v4.x, reverts to 16-bit mode with no advanced features.

  • Power Supply: Draws 4.0A on +5V rail—verify sufficient capacity.

SIEMENS 6ES7972-0BB42-0XA0
MITSUBISHI A6CON1 1.5
HONEYWELL 914CE1-Q

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NMEC1D1C”

Your email address will not be published. Required fields are marked *

Post comment