GE DS3800NMEC1B1A

¥999.00

The DS3800NMEC1B1A is a specific revision of General Electric’s Mark V series Fan/Exhaust Control board, designed for standard-voltage AC/DC applications with a hybrid output configuration. The suffix “1B1A” indicates Revision B firmware with enhanced 16-bit ADC (±1°C accuracy), standard temperature components (0°C to +60°C), 5A mechanical relay outputs, and 2A solid-state outputs. This board provides:

  • 8 mechanical relays (5A @ 115VAC / 30VDC) for high-power AC/DC fan control

  • 4 solid-state outputs (2A @ 24–48VDC) for low-voltage auxiliary fans or alarms

  • 4 thermocouple input channels for temperature monitoring

  • No tachometer feedback capability

The DS3800NMEC1B1A is a direct upgrade from the base DS3800NMEC, offering improved temperature accuracy (16-bit vs. 12-bit ADC) and Revision B firmware enhancements.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NMEC1B1A
Power Supply +5V DC @ 3.6A, +15V DC @ 0.6A, -15V DC @ 0.4A
Temperature Inputs 4 thermocouple channels (Type J/K/T, 16-bit ADC, ±1°C accuracy)
Relay Outputs 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A)
SS Outputs 4 solid-state relays, 2A continuous @ 24–48VDC
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, Relay Run (8x amber), SS Run (4x green), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • Hybrid Output Architecture: Combines 8 mechanical relays (5A) with 4 solid-state outputs (2A) on a single board.

  • Improved Temperature Accuracy (16-bit ADC): ±1°C accuracy—double the precision of the base 12-bit (±2°C) model.

  • Higher Relay Current (5A): Supports larger AC/DC fans compared to standard 3A hybrid boards.

  • Fan-Dense Design: 8 relay outputs + 4 SS outputs with only 4 temperature inputs—optimized for single-zone cooling.

  • Solid-State Auxiliary Outputs: Silent, maintenance-free switching for low-voltage fans or alarms.

  • Enhanced Cold-Junction Compensation (Revision B): Improved temperature measurement reliability.


Typical Application Fields

  • Fan-Dense Mixed Fan Cabinets: Where both high-power AC/DC fans and low-voltage DC auxiliary fans are present.

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.

  • Upgrade from Base NMEC: For improved temperature accuracy.


Comparison with Related Models

Feature DS3800NMEC1B1A DS3800NMEC (Base) DS3800NMEA DS3800NLCA
Relay Outputs 8 × 5A 8 × 5A 8 × 3A 8 × 3A
SS Outputs 4 × 2A 4 × 2A 4 × 2A None
T/C Inputs 4 4 8 4
ADC Resolution 16-bit (±1°C) 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C)
Tach Inputs None None None 2 channels
Operating Temp 0°C to +60°C 0°C to +60°C 0°C to +60°C 0°C to +60°C
Firmware B A A/B A/B
Cost Medium Medium Medium Medium

Selection Recommendations

  • Choose the DS3800NMEC1B1A if:

    • You need 5A relay outputs (AC or DC) for main fans.

    • You also need solid-state outputs (24–48VDC) for auxiliary fans or alarms.

    • You want improved temperature accuracy (±1°C).

    • You want to combine both functions in a single board.

    • Your cabinet uses 4 temperature sensors for 8 relay outputs + 4 SS outputs.

    • You have a climate-controlled environment (0°C to +60°C).

  • Choose the DS3800NMEA if: You need 8 thermocouple inputs with hybrid outputs.

  • Choose the DS3800NLCA if: You need tachometer feedback with relay outputs.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • High-Voltage/Current Hazard: Relay outputs switch 115VAC/5A—lethal voltage/current present. Use proper insulation.

  • Relay Inductive Derating: For inductive fan motors, derate from 5A to 3.5A or use RC snubbers.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • SS Current Limitation: Rated at 2A continuous @ 24–48VDC.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • No Tachometer Inputs: Do not connect speed sensors.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.

  • Firmware Compatibility: Revision B firmware is compatible with Mark V CPU firmware v4.0 and above. For v3.x, the enhanced ADC accuracy may be partially disabled—confirm compatibility before purchasing.