Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NMEC |
| Power Supply | +5V DC @ 3.6A, +15V DC @ 0.6A, -15V DC @ 0.4A |
| Temperature Inputs | 4 thermocouple channels (12-bit ADC, ±2°C accuracy) |
| Relay Outputs | 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A) |
| SS Outputs | 4 solid-state relays, 2A continuous @ 24–48VDC |
| Tachometer Inputs | None |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | 0°C to +60°C |
| LED Indicators | Power, Relay Run (8x amber), SS Run (4x green), Over-Temp Alarm, Backplane Active |
Advantages and Distinctive Features
-
Hybrid Output Architecture: Combines 8 mechanical relays (5A) with 4 solid-state outputs (2A) on a single board.
-
Higher Relay Current (5A): Supports larger AC/DC fans compared to standard 3A hybrid boards.
-
AC/DC Relay Capability: Relay outputs switch both AC (115VAC) and DC (30VDC) loads.
-
Fan-Dense Design: 8 relay outputs + 4 SS outputs with only 4 temperature inputs—optimized for single-zone cooling.
-
Solid-State Auxiliary Outputs: Silent, maintenance-free switching for low-voltage fans or alarms.
-
Complete Galvanic Isolation: 2500V isolation on relay outputs.
-
CPU-Dependent Operation: No onboard logic—simple and cost-effective.
Typical Application Fields
-
Fan-Dense Mixed Fan Cabinets: Where both high-power AC/DC fans and low-voltage DC auxiliary fans are present.
-
Climate-Controlled Indoor Installations: 0°C to +60°C range.
-
Retrofit Applications: Replacing separate relay and solid-state boards with a single hybrid solution.
Comparison with Related Models
| Feature | DS3800NMEC | DS3800NMEA | DS3800NLCA | DS3800NISA |
|---|---|---|---|---|
| Relay Outputs | 8 × 5A @ 115VAC/30VDC | 8 × 3A @ 115VAC/30VDC | 8 × 3A @ 115VAC/30VDC | None |
| SS Outputs | 4 × 2A @ 48VDC | 4 × 2A @ 48VDC | None | 8 × 2A @ 48VDC |
| T/C Inputs | 4 | 8 | 4 | 4 |
| Tach Inputs | None | None | 2 channels | None |
| ADC | 12-bit (±2°C) | 12-bit (±2°C) | 12-bit (±2°C) | 12-bit (±2°C) |
| Operating Temp | 0°C to +60°C | 0°C to +60°C | 0°C to +60°C | 0°C to +60°C |
| Cost | Medium | Medium | Medium | Low |
Selection Recommendations
-
Choose the DS3800NMEC if:
-
You need 5A relay outputs (AC or DC) for main fans.
-
You also need solid-state outputs (24–48VDC) for auxiliary fans or alarms.
-
You want to combine both functions in a single board.
-
Your cabinet uses 4 temperature sensors for 8 relay outputs + 4 SS outputs (fan-dense configuration).
-
You do not require tachometer feedback.
-
You have a climate-controlled environment (0°C to +60°C).
-
-
Choose the DS3800NMEA if: You need 8 thermocouple inputs with hybrid outputs.
-
Choose the DS3800NLCA if: You need tachometer feedback with relay outputs.
-
Choose the DS3800NISA if: You need only solid-state DC outputs.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap.
-
High-Voltage/Current Hazard: Relay outputs switch 115VAC/5A—lethal voltage/current present. Use proper insulation.
-
Relay Inductive Derating: For inductive fan motors, derate from 5A to 3.5A or use RC snubbers.
-
DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.
-
SS Current Limitation: Rated at 2A continuous @ 24–48VDC.
-
Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.
-
No Tachometer Inputs: Do not connect speed sensors.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.
-
Firmware Compatibility: Compatible with all Mark V CPU firmware versions (v3.x and above).