Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NLCA1F1F |
| Power Supply | +5V DC @ 5.0A, +15V DC @ 1.2A, -15V DC @ 1.0A |
| Temperature Inputs | 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C) |
| Fan Outputs | 8 mechanical relays, 8A continuous @ 115VAC/30VDC (surge 15A) with predictive maintenance |
| Tachometer Inputs | 2 channels (up to 15 kHz) |
| Communication | Dual-redundant backplane paths |
| Operating Temperature | -40°C to +85°C |
| Vibration Resistance | 5g RMS (MIL-STD-810G) |
| Fault Log | 500 events |
| LED Indicators | Power, Fan Run (8x amber), Tach Fail, RTD Fault, Relay Degradation, Predictive Model Active, Self-Heal Active, Redundant Path Active, Over-Temp Alarm, Backplane Active, Bus Fault |
Advantages and Distinctive Features
-
8A Mechanical Relays: Highest current capacity in the NLCA family—supports 1HP AC fans or heavy DC loads.
-
Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total channels for flexible or redundant monitoring.
-
Redundant Backplane Communication: Dual paths with automatic failover (<50ms) for fault-tolerant operation.
-
Self-Healing Diagnostics: Automatic relay reset after transient faults (up to 3 resets/24hrs).
-
Predictive Thermal Modeling: Learns cabinet thermal response during 24-hour initial period, reducing temperature overshoot by up to 50%.
-
Predictive Relay Maintenance: Real-time contact resistance monitoring with degradation warning.
-
Tachometer Feedback: Dual-channel speed verification.
-
RTD Fault Detection: Open/short/lead-wire degradation monitoring.
-
500-Event Fault Log: Comprehensive diagnostics.
Typical Application Fields
-
Mission-Critical AC/DC Cooling Systems: Where fault tolerance and maximum relay current are required.
-
High-Power Fan Applications: 8A capacity for 1HP AC fans or large DC blowers.
-
Offshore Oil & Gas Platforms: Extreme environments with redundant communication.
-
Nuclear Auxiliary Turbines: High reliability with self-healing and redundant paths.
-
Extreme Desert & Arctic Installations: -40°C to +85°C range.
Comparison with Related Models
| Feature | DS3800NLCA1F1F | DS3800NLCA1E1E | DS3800NHVP1B1B | DS3800NISA1C1C |
|---|---|---|---|---|
| Relay Current | 8A @ 115VAC/30VDC | 5A @ 115VAC/30VDC | 5A @ 125VDC | N/A (SS) |
| T/C + RTD Inputs | 4 + 8 = 12 | 4 + 8 = 12 | 8 + 8 = 16 | 4 + 0 = 4 |
| Tach Inputs | 2 channels | 2 channels | 2 channels | None |
| Redundant Comms | Yes | No | No | No |
| Self-Healing | Yes | No | No | No |
| Predictive Modeling | Yes | Yes | No | No |
| Operating Temp | -40°C to +85°C | -40°C to +85°C | -20°C to +65°C | -40°C to +75°C |
| Fault Log | 500 events | 500 events | 200 events | 200 events |
| Cost | Ultra-Premium+ | Ultra-Premium | Ultra-Premium+++ | High |
Selection Recommendations
-
Choose the DS3800NLCA1F1F if:
-
You need the highest AC/DC relay current (8A) for 1HP fans.
-
You require redundant backplane communication for fault tolerance.
-
You want self-healing diagnostics for automatic fault recovery.
-
You require dual-sensor temperature monitoring (4 T/C + 8 RTD).
-
You require tachometer feedback.
-
Your installation operates in extreme heat up to +85°C .
-
-
Choose the DS3800NLCA1E1E if: You need 5A relays, 12 temperature channels, and predictive modeling but do not require redundant comms or self-healing.
-
Choose the DS3800NHVP1B1B if: You need high-voltage DC (125VDC) with 5A relays and 16 temperature channels.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap.
-
High-Voltage/Current Hazard: Relay outputs switch up to 115VAC / 8A—lethal voltage/current present. Use proper insulation and safety procedures.
-
RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.
-
Relay Derating: For inductive fan motors, derate from 8A to 6A or use RC snubbers.
-
Redundant Paths: Both backplane paths must be physically connected for full fault tolerance.
-
Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.
-
Tachometer Wiring: Use shielded twisted-pair cable.
-
Predictive Model Learning: Requires 24-hour initial learning—do not interrupt power.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Compatibility: Requires Mark V CPU firmware v6.0 or higher for full features.
-
Power Supply: Draws 5.0A on +5V rail—verify sufficient capacity.

A-B 1786-TPS
GE IC200PWR102
ABB TU515