GE DS3800NLCA1E1E

¥999.00

The DS3800NLCA1E1E is a flagship revision of General Electric’s Mark V series Fan/Exhaust Control board, engineered for standard-voltage AC/DC applications with mechanical relay outputs, tachometer feedback, and dual temperature sensor support. The suffix “1E1E” indicates Revision E firmware with 24-bit ADC (±0.5°C / ±0.3°C accuracy), extended temperature components (-40°C to +85°C), military-grade vibration tolerance (5g RMS), 5A mechanical relay outputs4 thermocouple input channels8 RTD input channels (Pt100, 3-wire) for a total of 12 temperature channels, and 2 tachometer input channels.

The DS3800NLCA1E1E combines relay-based fan control with dual-sensor temperature monitoring (T/C + RTD), tachometer feedback, predictive relay maintenance, predictive thermal modeling, and extreme environmental tolerance (-40°C to +85°C)—making it the ultimate fan-dense relay-based board in the Mark V lineup.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NLCA1E1E
Power Supply +5V DC @ 4.2A, +15V DC @ 0.8A, -15V DC @ 0.6A
Temperature Inputs 4 thermocouple + 8 RTD = 12 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
Fan Outputs 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A) with predictive maintenance
Tachometer Inputs 2 channels (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature -40°C to +85°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 500 events
LED Indicators Power, Fan Run (8x amber), Tach Fail (red x2), Over-Temp Alarm, RTD Fault (yellow), Relay Degradation (orange), Predictive Model Active (blue), Model Learning (flashing blue), Backplane Active, Bus Fault

Advantages and Distinctive Features

  • Dual Temperature Sensor Support (4 T/C + 8 RTD): 12 total temperature channels—ideal for RTD-heavy applications with limited T/C requirements.

  • 5A Mechanical Relays with Predictive Maintenance: Supports larger AC/DC fans with real-time contact resistance monitoring.

  • Tachometer Feedback: Dual tachometer inputs for fan speed verification.

  • Predictive Thermal Modeling (Revision E): Learns cabinet thermal response during 24-hour initial period, reducing temperature overshoot by up to 50%.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C for thermocouples, ±0.3°C for RTDs.

  • RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.

  • Extended +85°C Operation: Surpasses the +75°C limit for extreme environments.

  • AC/DC Output Capability: Switches both AC (115VAC) and DC (30VDC) loads.

  • 500-Event Fault Log: Comprehensive diagnostics.


Typical Application Fields

  • Safety-Critical AC/DC Cooling Systems: With redundant RTD-based temperature monitoring and fan failure detection.

  • RTD-Heavy Cabinets: Where RTD sensors are preferred over thermocouples.

  • Extreme Desert Solar-Thermal Plants: +85°C ambient environments.

  • Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.

  • Arctic Installations: -40°C low-temperature tolerance.

  • Nuclear Auxiliary Turbines: High reliability with redundant temperature sensing.


Comparison with Related Models

Feature DS3800NLCA1E1E DS3800NLCA1D1C DS3800NLBA1D1D DS3800NHVM1E1C
Output Type Mechanical relay Mechanical relay Mechanical relay Mechanical relay
Output Current 5A 5A 5A 3A @ 125VDC
T/C + RTD Inputs 4 + 8 = 12 4 + 0 = 4 4 + 0 = 4 4 + 8 = 12
Tach Inputs 2 channels 2 channels None 2 channels
Predictive Thermal Modeling Yes No No Yes
Predictive Maintenance Yes Yes Yes Yes
ADC Resolution 24-bit 24-bit 24-bit 24-bit
Operating Temp -40°C to +85°C -40°C to +75°C -40°C to +75°C -40°C to +85°C
Vibration 5g RMS 5g RMS 5g RMS 5g RMS
Fault Log 500 events 200 events 200 events 500 events
Cost Ultra-Premium High High Ultra-Premium

Selection Recommendations

  • Choose the DS3800NLCA1E1E if:

    • You need 5A mechanical relay outputs (AC or DC).

    • You require both thermocouple and RTD inputs (12 total channels).

    • You require tachometer feedback for fan speed verification.

    • You want predictive thermal modeling for proactive temperature management.

    • You need predictive relay maintenance .

    • Your installation operates in extreme heat up to +85°C with high vibration.

    • You need 500-event fault logging.

  • Choose the DS3800NLCA1D1C if: You need 5A relays and tachometer feedback but only require thermocouple inputs and +75°C operation.

  • Choose the DS3800NHVM1E1C if: You need 3A @ 125VDC relay outputs with 12 temperature channels and predictive modeling.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.

  • RTD Lead Resistance: Use wire with resistance ≤10Ω per lead for accurate measurements.

  • Relay Derating: For inductive fan motors, derate from 5A to 3.5A or use RC snubbers.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal—not at the fan end.

  • Predictive Model Learning: Requires 24-hour initial learning period—do not interrupt power.

  • Model Reset: Reset via Mark V software if cabinet configuration changes.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.

  • Firmware Compatibility: Revision E requires Mark V CPU firmware v5.5 or higher for full predictive modeling, RTD support, predictive maintenance, and 24-bit ADC. For v5.0–v5.4, predictive modeling disabled (RTD, maintenance, and ADC still function). For v4.x, reverts to 16-bit mode.

  • Power Supply: Draws 4.2A on +5V rail—verify sufficient capacity.

A-B 1734-EP24DC