Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NLCA1D1C |
| Power Supply | +5V DC @ 3.8A, +15V DC @ 0.6A, -15V DC @ 0.4A |
| Temperature Inputs | 4 thermocouple channels (Type J/K/T, 24-bit ADC, ±0.5°C accuracy) |
| Fan Outputs | 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A) |
| Tachometer Inputs | 2 channels (up to 10 kHz) |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | -40°C to +75°C |
| Vibration Resistance | 5g RMS (MIL-STD-810G) |
| Fault Log | 200 events |
| LED Indicators | Power, Fan Run (8x amber), Tach Fail (red x2), Over-Temp Alarm, Relay Degradation Warning, Backplane Active, Bus Fault |
Advantages and Distinctive Features
-
5A Mechanical Relays: 67% higher current capacity than the base 3A model—supports larger AC/DC fans.
-
Tachometer Feedback: Dual tachometer inputs for fan speed verification—critical for safety-critical applications.
-
24-Bit Ultra-High Precision ADC: ±0.5°C accuracy for precise thermal management.
-
Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.
-
Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.
-
Fan-Dense Design: 8 outputs with only 4 temperature inputs—optimized for single-zone cooling.
-
AC/DC Output Capability: Switches both AC (115VAC) and DC (30VDC) loads.
-
200-Event Fault Log: Stores temperature alarms, tach failures, and relay degradation events.
Typical Application Fields
-
Safety-Critical AC/DC Cooling Systems: Where fan failure detection and relay health monitoring are mandatory.
-
Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.
-
Desert Power Plants: 75°C upper limit.
-
Arctic Compressor Stations: -40°C low-temperature tolerance.
-
Fan-Dense Cabinets: Where 8 fans serve a single zone with 4 sensors.
Comparison with Related Models
| Feature | DS3800NLCA1D1C | DS3800NLCA (Base) | DS3800NLBA1D1D | DS3800NITA1C1D |
|---|---|---|---|---|
| Output Type | Mechanical relay | Mechanical relay | Mechanical relay | Solid-state |
| Output Current | 5A | 3A | 5A | 3A |
| T/C Inputs | 4 | 4 | 4 | 4 |
| Tach Inputs | 2 channels | 2 channels | None | 2 channels |
| ADC Resolution | 24-bit (±0.5°C) | 12-bit (±2°C) | 24-bit (±0.5°C) | 24-bit (±0.5°C) |
| Predictive Maintenance | Yes | No | Yes | No |
| Operating Temp | -40°C to +75°C | 0°C to +60°C | -40°C to +75°C | -40°C to +75°C |
| Vibration | 5g RMS | 1g RMS | 5g RMS | 5g RMS |
| Fault Log | 200 events | Basic | 200 events | 200 events |
| Cost | High | Medium | High | High |
Selection Recommendations
-
Choose the DS3800NLCA1D1C if:
-
You need 5A mechanical relay outputs (AC or DC).
-
Your cabinet uses 4 temperature sensors for 8 fan outputs.
-
You require tachometer feedback for fan speed verification.
-
You want ultra-precise temperature monitoring (±0.5°C).
-
You need predictive relay maintenance.
-
Your installation is in extreme environments (-40°C to +75°C) with high vibration.
-
-
Choose the DS3800NLBA1D1D if: You need 5A relay outputs without tachometer feedback.
-
Choose the DS3800NITA1C1D if: You prefer solid-state outputs (3A) with tachometer feedback and the same extreme temperature range.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.
-
Relay Derating: For inductive fan motors, derate from 5A to 3.5A or use RC snubbers.
-
Relay Contact Wear: Predictive maintenance monitors contact resistance—replace board when degradation LED illuminates.
-
Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.
-
Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal—not at the fan end.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.
-
Firmware Compatibility: Revision D firmware requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, predictive maintenance, and tachometer functionality. For v4.x, reverts to 16-bit mode with no predictive maintenance.
-
Power Supply: Draws 3.8A on +5V rail—verify sufficient capacity.

A-B 1786-TPS
TURCK MK1-2AP/24V
A-B 2090-CPWM7DF-16AA05


Reviews
There are no reviews yet.