GE DS3800NLBA

¥999.00

The DS3800NLBA is a Fan/Exhaust Control board from General Electric’s Mark V Speedtronic™ series, designed for standard-voltage AC/DC applications with mechanical relay outputs. The “NLBA” designation indicates a board with:

  • 8 mechanical relays (3A @ 115VAC / 30VDC) for fan control

  • 4 thermocouple input channels for temperature monitoring

  • No tachometer feedback capability

  • 12-bit ADC (±2°C accuracy)

  • Standard temperature range (0°C to +60°C)

The DS3800NLBA is a cost-effective, relay-based fan control board optimized for fan-dense cabinets where AC or DC fan switching is required, but tachometer feedback is not necessary. It relies entirely on the Mark V CPU for control logic.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NLBA
Power Supply +5V DC @ 3.0A, +15V DC @ 0.5A, -15V DC @ 0.3A
Temperature Inputs 4 thermocouple channels (12-bit ADC, ±2°C accuracy)
Fan Outputs 8 mechanical relays, 3A continuous @ 115VAC/30VDC (surge 5A)
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, Fan Run (8x amber), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • AC/DC Output Capability: Switches both AC (115VAC) and DC (30VDC) loads—versatile for mixed cabinet installations.

  • Fan-Dense Design: 8 outputs with only 4 temperature inputs—optimized for single-zone cooling.

  • Mechanical Relay Isolation: 2500V galvanic isolation between control logic and fan power.

  • High Surge Handling: 5A surge capacity for fan startup currents.

  • Cost-Effective: Simple, CPU-dependent operation with no onboard logic.


Typical Application Fields

  • Fan-Dense Cabinets: Where 8 fans serve a single zone with 4 sensors.

  • Mixed AC/DC Fan Installations: Where both AC and DC fans are present.

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.

  • Budget-Conscious Applications: Cost-effective relay-based solution.


Comparison with Related Models

Feature DS3800NLBA DS3800NISA DS3800NGTA DS3800NFEE
Output Type Mechanical relay Solid-state Mechanical relay Mechanical relay
Output Current 3A 2A 3A 3A
T/C Inputs 4 4 8 8
Tach Inputs None None None None
AC Capability Yes No Yes Yes
ADC 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C)
Operating Temp 0°C to +60°C 0°C to +60°C 0°C to +60°C 0°C to +60°C
Cost Low Low Low Low

Selection Recommendations

  • Choose the DS3800NLBA if:

    • You need 3A mechanical relay outputs (AC or DC).

    • Your cabinet uses 4 temperature sensors for 8 fan outputs.

    • You do not require tachometer feedback.

    • You have a climate-controlled environment (0°C to +60°C).

    • The Mark V CPU handles all control logic.

  • Choose the DS3800NISA if: You prefer solid-state DC outputs (silent, maintenance-free).

  • Choose the DS3800NGTA if: You need 8 temperature inputs with relay outputs.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • Relay Contact Wear: Rated for 100,000 operations at 3A.

  • Inductive Load Derating: For inductive fan motors, derate to 2A or use external RC snubbers.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • No Tachometer Inputs: Do not connect speed sensors.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.

  • Firmware Compatibility: Compatible with all Mark V CPU firmware versions (v3.x and above).

SIEMENS 6ES7972-0BB12-OXAO
A-B 1492-SPM2B060
A-B 1786-TPS

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NLBA”

Your email address will not be published. Required fields are marked *