GE DS3800NISA1C1D

¥999.00

The DS3800NISA1C1D is a premium revision of General Electric’s Mark V series Fan/Exhaust Control board, designed for standard-voltage DC applications. The suffix “1C1D” indicates Revision C firmware with 24-bit ADC (±0.5°C accuracy), extended temperature components (-40°C to +75°C), military-grade vibration tolerance (5g RMS), 3A solid-state outputs, and 4 thermocouple input channels—with no tachometer feedback. Critically, the “1D” suffix adds adaptive temperature averaging to reduce unnecessary fan cycling.

This board is a direct upgrade from the “1C1C” variant, adding adaptive averaging that smooths rapid temperature fluctuations, reducing fan cycling by up to 30% and extending fan bearing life.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NISA1C1D
Power Supply +5V DC @ 3.5A, +15V DC @ 0.6A, -15V DC @ 0.4A
Temperature Inputs 4 thermocouple channels (Type J/K/T, 24-bit ADC, ±0.5°C accuracy)
Fan Outputs 8 solid-state relays, 3A continuous @ 24–48VDC (surge 5A)
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature -40°C to +75°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 200 events
LED Indicators Power, Fan Run (8x green), Over-Temp Alarm, Adaptive Averaging Active (blue), Fallback Active (yellow), Bus Fault

Advantages and Distinctive Features

  • Adaptive Temperature Averaging (Revision C + 1D): Smooths rapid temperature fluctuations, reducing unnecessary fan cycling by up to 30%—extending fan bearing life and reducing acoustic noise.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C accuracy for precise thermal management.

  • Onboard Temperature Threshold Logic: Autonomous ON/OFF fan control during backplane communication loss.

  • 3A Solid-State Outputs: Supports larger DC fans or multiple fans in parallel.

  • Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.

  • Fan-Dense Design: 8 outputs with only 4 temperature inputs—optimized for single-zone cooling.

  • Silent, Maintenance-Free Operation: Unlimited switching cycles with no contact wear.

  • 200-Event Fault Log: Stores temperature alarms and fallback events.


Typical Application Fields

  • Offshore Oil & Gas Platforms: Extreme environments with reduced fan cycling.

  • Desert Power Plants: 75°C upper limit with adaptive smoothing.

  • Arctic Compressor Stations: -40°C low-temperature tolerance.

  • High-Cycle Applications: Adaptive averaging reduces switching frequency.

  • Remote Unstaffed Stations: Autonomous fallback with reduced fan wear.


Comparison with Related Models

Feature DS3800NISA1C1D DS3800NISA1C1C DS3800NISA1B1B DS3800NFMC1E1C
Output Current 3A 3A 3A 3A
T/C Inputs 4 4 4 4
ADC Resolution 24-bit (±0.5°C) 24-bit (±0.5°C) 16-bit (±1°C) 24-bit (±0.5°C)
Onboard Logic Yes (threshold + averaging) Yes (threshold only) No Yes (threshold + averaging)
Adaptive Averaging Yes No No Yes
Operating Temp -40°C to +75°C -40°C to +75°C -20°C to +65°C -40°C to +75°C
Vibration 5g RMS 5g RMS 2g RMS 5g RMS
Fault Log 200 events 200 events Basic 200 events
Cost High High Medium High

Selection Recommendations

  • Choose the DS3800NISA1C1D if:

    • Your fans are DC-powered (24V or 48V) with current draw ≤3A.

    • Your cabinet uses 4 temperature sensors for 8 fan outputs.

    • You want ultra-precise temperature monitoring (±0.5°C).

    • You want adaptive averaging to reduce fan cycling and extend fan life.

    • You need autonomous fallback cooling during CPU communication loss.

    • Your installation is in extreme environments (-40°C to +75°C) with high vibration.

    • You do not require tachometer feedback.

  • Choose the DS3800NFMC1E1C if: You need the same features with 8 thermocouple inputs instead of 4.

  • Choose the DS3800NISA1C1C if: You need the same features but without adaptive averaging.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • DC Polarity: Solid-state outputs are DC-only and polarity-sensitive. Reverse polarity destroys the output MOSFET.

  • Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.

  • Current Derating: At 75°C, derate to 2.2A per output.

  • Missing T/C Channels: Only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent.

  • No Tachometer Inputs: Do not connect speed sensors.

  • Adaptive Averaging Tuning: The averaging window (default 10 seconds) can be adjusted via Mark V software.

  • Fallback Configuration: Thresholds must be configured via Mark V software. If not configured, defaults to 100% fan speed.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board enters autonomous fallback—adaptive averaging disabled in fallback mode.

  • Firmware Compatibility: Revision C firmware requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, autonomous logic, and adaptive averaging. For v4.x, reverts to 16-bit mode with no advanced features.

  • Power Supply: Draws 3.5A on +5V rail—verify sufficient capacity.

A-B 1794-TB2
A-B 1786-TPS
A-B 1786-TPS
GE IC695SPF002

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NISA1C1D”

Your email address will not be published. Required fields are marked *

Post comment