GE DS3800NHVP1B1B

¥999.00

The DS3800NHVP1B1B is a high-performance revision of General Electric’s Mark V series Fan/Exhaust Control board, engineered for high-voltage DC applications with a hybrid output configuration. The suffix “1B1B” indicates Revision B firmware with 24-bit ADC (±0.5°C / ±0.3°C accuracy), extended temperature components (-20°C to +65°C), and predictive relay maintenance. The “NHVP” designation indicates a board with:

  • 8 mechanical relays (5A @ 125VDC)—the highest relay current in the entire Mark V high-voltage DC lineup, supporting the most demanding 125VDC exhaust fans

  • 4 solid-state outputs (4A @ 24–48VDC)—with individual current monitoring

  • 8 thermocouple input channels for temperature monitoring

  • 8 RTD input channels (Pt100, 3-wire) for high-precision temperature monitoring—adding 16 total temperature channels

  • 2 tachometer input channels for fan speed verification

The DS3800NHVP1B1B represents the ultimate in high-voltage DC fan control, combining the absolute highest relay current (5A @ 125VDC) with dual-sensor temperature monitoring, high-current solid-state outputs, tachometer feedback, 24-bit ADC, predictive relay maintenance, and an extended temperature range (-20°C to +65°C).

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NHVP1B1B
Power Supply +5V DC @ 7.0A, +15V DC @ 2.0A, -15V DC @ 1.5A
Temperature Inputs 8 thermocouple + 8 RTD = 16 total channels (24-bit ADC, ±0.5°C / ±0.3°C)
Relay Outputs 8 mechanical relays, 5A continuous @ 125VDC (surge 10A) with predictive maintenance
SS Outputs 4 solid-state relays, 4A continuous @ 24–48VDC with individual current monitoring
Tachometer Inputs 2 channels with enhanced filtering (up to 10 kHz)
Communication Mark V proprietary parallel backplane bus
Operating Temperature -20°C to +65°C
Fault Log 200 events
LED Indicators Power, Relay Run (8x amber), SS Run (4x green), SS Overcurrent (flashing red), Tach Fail (red x2), RTD Fault (yellow), Relay Degradation (orange), Over-Temp Alarm, Backplane Active, Bus Fault

Advantages and Distinctive Features

  • Highest Relay Current (5A @ 125VDC): Delivers 5A continuous (10A surge)—the absolute highest current capacity of any high-voltage DC fan board in the Mark V lineup, supporting the largest 125VDC exhaust fans.

  • Highest Solid-State Outputs (4A): With individual current monitoring and overcurrent detection.

  • Full 16 Temperature Channels (8 T/C + 8 RTD): Comprehensive temperature monitoring without compromise.

  • 24-Bit Ultra-High Precision ADC: ±0.5°C for thermocouples, ±0.3°C for RTDs.

  • Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.

  • Hybrid Output + Tachometer Feedback: Combines 8 high-voltage DC relay outputs, 4 high-current solid-state outputs, AND 2 tachometer inputs.

  • RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.

  • Extended Temperature Range: -20°C to +65°C supports moderately harsh environments.


Typical Application Fields

  • Extreme High-Power 125VDC Cooling Systems: Where 5A @ 125VDC capacity is required for the largest exhaust fans.

  • Mixed Sensor Cabinets: Where both thermocouple and RTD sensors are used (16 total channels).

  • Unheated Shelters & Outdoor Enclosures: -20°C to +65°C range.

  • Legacy Turbine Installations: Requiring the highest relay current.

  • Large Auxiliary Fan Systems: Where 4A solid-state outputs are needed.


Comparison with Related Models

Feature DS3800NHVP1B1B DS3800NHVN1A1A DS3800NHVM1E1D DS3800NHVL
Relay Current 5A @ 125VDC 4A @ 125VDC 3A @ 125VDC 2A @ 125VDC
Relay Surge 10A 8A 6A 4A
SS Output Current 4A 4A 4A 3A
SS Current Monitoring Yes Yes Yes No
T/C + RTD Inputs 8 + 8 = 16 8 + 8 = 16 8 + 8 = 16 8 + 8 = 16
Predictive Thermal Modeling No No Yes No
ADC Resolution 24-bit 24-bit 24-bit 24-bit
Predictive Maintenance Yes Yes Yes Yes
Operating Temp -20°C to +65°C 0°C to +60°C -40°C to +85°C -40°C to +75°C
Fault Log 200 events 200 events 500 events 500 events
Cost Ultra-Premium+++ Ultra-Premium Ultra-Premium+++ Ultra-Premium

Selection Recommendations

  • Choose the DS3800NHVP1B1B if:

    • You need the absolute highest 125VDC relay current (5A) for the most powerful exhaust fans.

    • You need 4A solid-state outputs with individual current monitoring .

    • You require both thermocouple and RTD inputs (16 total channels).

    • You require tachometer feedback for fan speed verification.

    • You want predictive relay maintenance .

    • You need 24-bit ADC accuracy.

    • Your installation requires extended temperature range (-20°C to +65°C).

  • Choose the DS3800NHVN1A1A if: You need 4A relay current and 4A SS outputs in a climate-controlled environment.

  • Choose the DS3800NHVM1E1D if: You need 3A relay current with predictive thermal modeling and extreme temperature tolerance (-40°C to +85°C).


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.

  • High-Voltage Hazard: Relay outputs switch 125VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥125VDC.

  • RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.

  • RTD Lead Resistance: Use wire with resistance ≤10Ω per lead.

  • DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • SS Overcurrent Protection: If an output exceeds 4.5A, the green LED flashes red. Persistent overcurrent triggers a bus fault and disables the output.

  • SS Derating: At 65°C, derate to 3.2A per solid-state output.

  • Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal.

  • Relay Current Limitation: Rated at 5A continuous @ 125VDC. Verify fan current does not exceed this limit.

  • Inductive Load Derating (Relay): For inductive fan motors, derate to 4A or use external RC snubbers (rated for 125VDC).

  • No AC Connection: Do not connect AC loads to either output type.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.

  • Firmware Compatibility: The DS3800NHVP1B1B requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, predictive maintenance, and RTD support. For v4.x, the board reverts to 16-bit mode with no predictive maintenance.

  • Power Supply: Draws 7.0A on +5V rail—the highest of any Mark V fan board. A power supply upgrade is mandatory for all installations.

A-B 1787-PCABL
OMRON E5CN-R2MT-500
A-B 20-750-ENC-1

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NHVP1B1B”

Your email address will not be published. Required fields are marked *

Post comment