Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NHVN1A1A |
| Power Supply | +5V DC @ 6.5A, +15V DC @ 1.8A, -15V DC @ 1.5A |
| Temperature Inputs | 8 thermocouple + 8 RTD = 16 total channels (24-bit ADC, ±0.5°C / ±0.3°C) |
| Relay Outputs | 8 mechanical relays, 4A continuous @ 125VDC (surge 8A) with predictive maintenance |
| SS Outputs | 4 solid-state relays, 4A continuous @ 24–48VDC with individual current monitoring |
| Tachometer Inputs | 2 channels with enhanced filtering (up to 10 kHz) |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | 0°C to +60°C |
| Fault Log | 200 events |
| LED Indicators | Power, Relay Run (8x amber), SS Run (4x green), SS Overcurrent (flashing red), Tach Fail (red x2), RTD Fault (yellow), Relay Degradation (orange), Over-Temp Alarm, Backplane Active, Bus Fault |
Advantages and Distinctive Features
-
Highest Relay Current (4A @ 125VDC): Delivers 4A continuous (8A surge)—the highest current capacity of any high-voltage DC fan board in the Mark V lineup, supporting the largest 125VDC exhaust fans.
-
Highest Solid-State Outputs (4A): The highest current rating for solid-state auxiliaries in the high-voltage lineup, with individual current monitoring and overcurrent detection.
-
Full 16 Temperature Channels (8 T/C + 8 RTD): Comprehensive temperature monitoring without compromise.
-
24-Bit Ultra-High Precision ADC: ±0.5°C for thermocouples, ±0.3°C for RTDs.
-
Predictive Relay Maintenance: Real-time contact resistance monitoring with relay degradation warning.
-
Hybrid Output + Tachometer Feedback: Combines 8 high-voltage DC relay outputs, 4 high-current solid-state outputs, AND 2 tachometer inputs.
-
RTD Fault Detection: Continuous monitoring for open-circuit, short-circuit, or lead-wire degradation.
-
Baseline Revision A: The original version of this flagship board—ideal for direct replacement in legacy systems.
Typical Application Fields
-
High-Power 125VDC Cooling Systems: Where 4A @ 125VDC capacity is required for the largest exhaust fans.
-
Mixed Sensor Cabinets: Where both thermocouple and RTD sensors are used (16 total channels).
-
Climate-Controlled Indoor Installations: 0°C to +60°C range.
-
Legacy Turbine Installations: Direct replacement for original DS3800NHVN boards.
-
Large Auxiliary Fan Systems: Where 4A solid-state outputs are needed.
Comparison with Related Models
| Feature | DS3800NHVN1A1A | DS3800NHVN (Base) | DS3800NHVM1E1D | DS3800NHVL |
|---|---|---|---|---|
| Relay Current | 4A @ 125VDC | 4A @ 125VDC | 3A @ 125VDC | 2A @ 125VDC |
| Relay Surge | 8A | 8A | 6A | 4A |
| SS Output Current | 4A | 4A | 4A | 3A |
| SS Current Monitoring | Yes | Yes | Yes | No |
| T/C + RTD Inputs | 8 + 8 = 16 | 8 + 8 = 16 | 8 + 8 = 16 | 8 + 8 = 16 |
| Predictive Thermal Modeling | No | No | Yes | No |
| ADC Resolution | 24-bit | 24-bit | 24-bit | 24-bit |
| Predictive Maintenance | Yes | Yes | Yes | Yes |
| Operating Temp | 0°C to +60°C | -40°C to +85°C | -40°C to +85°C | -40°C to +75°C |
| Fault Log | 200 events | 500 events | 500 events | 500 events |
| Firmware | A | A/B | E | A/B |
| Cost | Ultra-Premium | Ultra-Premium++++ | Ultra-Premium+++ | Ultra-Premium |
Selection Recommendations
-
Choose the DS3800NHVN1A1A if:
-
You need the highest 125VDC relay current (4A) for the most powerful exhaust fans.
-
You need 4A solid-state outputs with individual current monitoring .
-
You require both thermocouple and RTD inputs (16 total channels).
-
You require tachometer feedback for fan speed verification.
-
You want predictive relay maintenance .
-
You need 24-bit ADC accuracy.
-
You have a climate-controlled environment (0°C to +60°C).
-
You need a direct replacement for an existing DS3800NHVN board.
-
-
Choose the DS3800NHVM1E1D if: You need 3A relay current, predictive thermal modeling, and extreme temperature tolerance (-40°C to +85°C).
-
Choose the full DS3800NHVN if: You need the same 4A relay current and 4A SS outputs but require extreme temperature tolerance (-40°C to +85°C) and 500-event logging.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy.
-
High-Voltage Hazard: Relay outputs switch 125VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥125VDC.
-
RTD Wiring: Use 3-wire Pt100 RTDs. All three wires must be connected. Open/short circuits trigger RTD Fault LED.
-
RTD Lead Resistance: Use wire with resistance ≤10Ω per lead.
-
DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.
-
DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.
-
SS Overcurrent Protection: If an output exceeds 4.5A, the green LED flashes red. Persistent overcurrent triggers a bus fault and disables the output.
-
Tachometer Wiring: Use shielded twisted-pair cable. Connect shield to designated terminal.
-
Relay Current Limitation: Rated at 4A continuous @ 125VDC. Verify fan current does not exceed this limit.
-
Inductive Load Derating (Relay): For inductive fan motors, derate to 3A or use external RC snubbers (rated for 125VDC).
-
No AC Connection: Do not connect AC loads to either output type.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed—all advanced features disabled in fallback mode.
-
Firmware Compatibility: The DS3800NHVN1A1A requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC, predictive maintenance, and RTD support. For v4.x, the board reverts to 16-bit mode with no predictive maintenance.
-
Power Supply: Draws 6.5A on +5V rail—the highest of any Mark V fan board. A power supply upgrade is mandatory for all installations.

NI PCI-6503
GE IC693CHS397E
GE IC693CHS391E/G


Reviews