Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NHVE1C1C |
| Power Supply | +5V DC @ 3.5A, +15V DC @ 0.5A, -15V DC @ 0.3A |
| Temperature Inputs | 4 differential thermocouple channels (Type J/K/T, 16-bit ADC, ±1°C accuracy) |
| Relay Outputs | 8 mechanical relays, 1A continuous @ 250VDC (surge 2A) |
| SS Outputs | 4 solid-state relays, 2A continuous @ 24–48VDC |
| Tachometer Inputs | None |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | -20°C to +65°C |
| LED Indicators | Power, Relay Run (8x amber), SS Run (4x green), Over-Temp Alarm, Backplane Active |
Advantages and Distinctive Features
-
Hybrid Output Architecture: Combines 8 high-voltage DC relay outputs (250VDC) with 4 low-voltage solid-state outputs (24–48VDC) on a single board.
-
Reduced Thermocouple Count (4 channels): Optimized for cabinets where fewer temperature sensors monitor multiple fan zones—reducing hardware cost while maintaining 8 fan outputs.
-
Extended Temperature Range: -20°C to +65°C supports moderately harsh environments.
-
Improved Cold-Junction Compensation (Revision C): Enhanced temperature measurement stability.
-
Enhanced Noise Filtering: Improved ADC input filtering for high-EMI environments.
-
250VDC Relay Capability: Supports high-voltage exhaust fans.
-
Solid-State Auxiliary Outputs: Silent, maintenance-free switching for low-voltage fans/alarms.
Typical Application Fields
-
Fan-Dense High-Voltage Cabinets: Where 8 fans cool a single zone monitored by only 4 temperature sensors.
-
High-Voltage Industrial Fan Systems: 220–250VDC exhaust fans with low-voltage auxiliary controls.
-
Railway and Traction Applications: High-voltage DC cooling with 24VDC control circuits.
-
Unheated Shelters & Outdoor Enclosures: -20°C to +65°C range.
Comparison with Related Models
| Feature | DS3800NHVE1C1C | DS3800NHVE1C1B | DS3800NHVE1B1B | DS3800NHVD1C1B |
|---|---|---|---|---|
| Relay Outputs | 8 × 1A @ 250VDC | 8 × 1A @ 250VDC | 8 × 1A @ 250VDC | 8 × 1A @ 250VDC |
| SS Outputs | 4 × 2A @ 48VDC | 4 × 2A @ 48VDC | 4 × 2A @ 48VDC | None |
| T/C Inputs | 4 channels | 8 channels | 8 channels | 8 channels |
| ADC Resolution | 16-bit (±1°C) | 16-bit (±1°C) | 16-bit (±1°C) | 16-bit (±1°C) |
| Enhanced CJC | Yes (Rev C) | Yes (Rev C) | No | Yes (Rev C) |
| Operating Temp | -20°C to +65°C | -20°C to +65°C | -20°C to +65°C | -20°C to +65°C |
| Cost | Medium | Medium-High | Medium-High | Medium-High |
Selection Recommendations
-
Choose the DS3800NHVE1C1C if:
-
You need 250VDC relay outputs for high-voltage exhaust fans.
-
You also need low-voltage solid-state outputs (24–48VDC) for auxiliary fans or alarms.
-
Your cabinet uses ≤4 temperature sensors for 8 fan outputs.
-
You want enhanced cold-junction compensation and noise filtering.
-
Your installation requires extended temperature range (-20°C to +65°C).
-
-
Choose the DS3800NHVE1C1B if: You need the same features but require 8 thermocouple inputs.
-
Choose the DS3800NHVE1B1B if: You need 8 thermocouple inputs and extended temperature range but do not require enhanced CJC or noise filtering.
Critical Precautions
-
ESD Protection: Always wear a grounded wrist strap.
-
Extreme High-Voltage Hazard: Relay outputs switch 250VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥250VDC.
-
Missing Thermocouple Channels: The DS3800NHVE1C1C has only 4 thermocouple inputs (channels 1–4). Channels 5–8 are physically absent and will not function—do not attempt to connect sensors.
-
DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.
-
DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.
-
Relay Current Limitation: Rated at 1A continuous @ 250VDC. Verify fan current does not exceed this limit.
-
SS Current Limitation: Rated at 2A continuous @ 24–48VDC.
-
Inductive Load Derating (Relay): Derate to 0.75A or use external RC snubbers (rated for 250VDC).
-
No AC Connection: Do not connect AC loads to either output type.
-
No Hot-Swap: Always depower the rack before insertion/removal.
-
Slot Assignment: Install in slots 8–10 (auxiliary I/O).
-
CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.
-
Firmware Compatibility: Revision C firmware is compatible with Mark V CPU firmware v4.0 and above. For v3.x, the enhanced ADC features may be partially disabled—confirm compatibility before purchasing.