GE DS3800NHVE1A1A

¥999.00

The DS3800NHVE1A1A is a specific revision of General Electric’s Mark V series Fan/Exhaust Control board, designed for high-voltage DC applications with a hybrid output configuration. The suffix “1A1A” indicates Revision A firmware (baseline), standard 12-bit ADC (±2°C accuracy), and standard temperature components (0°C to +60°C). This board provides:

  • 8 mechanical relays (1A @ 250VDC) for high-voltage exhaust fans

  • 4 solid-state outputs (2A @ 24–48VDC) for low-voltage circulating fans or alarms

  • 8 thermocouple input channels for temperature monitoring

The DS3800NHVE1A1A is the original, unmodified version of this hybrid high-voltage board—ideal for replacing like-for-like in legacy systems that require both 250VDC relay switching and 24–48VDC solid-state auxiliary control on a single board.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NHVE1A1A
Power Supply +5V DC @ 3.5A, +15V DC @ 0.6A, -15V DC @ 0.4A
Temperature Inputs 8 differential thermocouple channels (12-bit ADC, ±2°C accuracy)
Relay Outputs 8 mechanical relays, 1A continuous @ 250VDC (surge 2A)
SS Outputs 4 solid-state relays, 2A continuous @ 24–48VDC
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, Relay Run (8x amber), SS Run (4x green), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • Hybrid Output Architecture: The DS3800NHVE1A1A uniquely combines 8 high-voltage DC relay outputs (250VDC) with 4 low-voltage solid-state outputs (24–48VDC) on a single board.

  • 250VDC Relay Capability: Supports high-voltage exhaust fans for specialized industrial, railway, or turbine applications.

  • Solid-State Auxiliary Outputs: Silent, maintenance-free switching for low-voltage circulating fans or alarm indicators.

  • Full 8 Thermocouple Inputs: Comprehensive temperature monitoring.

  • Baseline Revision A: The DS3800NHVE1A1A is the original version of this board—ideal for direct replacement in legacy systems.


Typical Application Fields

  • High-Voltage Industrial Fan Systems: 220–250VDC exhaust fans with low-voltage auxiliary controls.

  • Railway and Traction Applications: High-voltage DC cooling with 24VDC control circuits.

  • Specialized Turbine Installations: Mixed high-voltage and low-voltage fan systems.

  • Legacy System Replacements: Direct drop-in replacement for original DS3800NHVE boards.


Comparison with Related Models

Feature DS3800NHVE1A1A DS3800NHVE (Base) DS3800NHVD DS3800NGRD
Relay Outputs 8 × 1A @ 250VDC 8 × 1A @ 250VDC 8 × 1A @ 250VDC None
SS Outputs 4 × 2A @ 48VDC 4 × 2A @ 48VDC None 8 × 2A @ 48VDC
T/C Inputs 8 8 8 8
ADC Resolution 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C)
Operating Temp 0°C to +60°C 0°C to +60°C 0°C to +60°C 0°C to +60°C
Firmware A (baseline) Unknown A/B A/B
Cost Medium Medium Medium Low

Selection Recommendations

  • Choose the DS3800NHVE1A1A if:

    • You need 250VDC relay outputs for high-voltage exhaust fans.

    • You also need low-voltage solid-state outputs (24–48VDC) for auxiliary fans or alarms.

    • You want to combine both functions in a single board.

    • You have a climate-controlled environment (0°C to +60°C).

    • You need a direct replacement for an existing DS3800NHVE board.

  • Choose the DS3800NHVD if: You need 250VDC relay outputs without solid-state auxiliary outputs.

  • Choose the DS3800NGRD if: You need only low-voltage solid-state outputs.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • Extreme High-Voltage Hazard: Relay outputs switch 250VDC—lethal voltage present on terminals. Observe all high-voltage safety procedures. Use wiring rated for ≥250VDC.

  • DC Polarity (Relay): Relay outputs are DC only—observe correct polarity.

  • DC Polarity (SS): Solid-state outputs are DC-only and polarity-sensitive—reverse polarity destroys the MOSFET.

  • Relay Current Limitation: Rated at 1A continuous @ 250VDC. Verify fan current does not exceed this limit.

  • SS Current Limitation: Rated at 2A continuous @ 24–48VDC.

  • Inductive Load Derating (Relay): Derate to 0.75A or use external RC snubbers (rated for 250VDC).

  • No AC Connection: Do not connect AC loads to either output type.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.

  • Firmware Compatibility: The DS3800NHVE1A1A is compatible with all Mark V CPU firmware versions (v3.x and above). No specific CPU upgrade is needed.

SCHNEIDER 520422000
SCHNEIDER LV429632
IBM DDLA-21620