GE DS3800NGRD1E1D

¥999.00

The DS3800NGRD1E1D is a premium revision of General Electric’s Mark V series Fan/Exhaust Control board. The suffix “1E1D” indicates Revision E firmware with 24-bit ADC (±0.5°C accuracy), extended temperature components (-40°C to +75°C), military-grade vibration tolerance (5g RMS), 3A solid-state DC outputs, and 8 thermocouple input channels—with no tachometer feedback.

This board transforms the basic solid-state “NGRD” family into a high-performance solution with ultra-precise temperature monitoring, extreme environmental tolerance, and predictive diagnostics.

Category:

Description

Key Technical Parameters

Parameter Specification
Full Model DS3800NGRD1E1D
Power Supply +5V DC @ 3.8A, +15V DC @ 0.7A, -15V DC @ 0.5A
Temperature Inputs 8 thermocouple channels (Type J/K/T, 24-bit ADC, ±0.5°C accuracy)
Fan Outputs 8 solid-state relays, 3A continuous @ 24–48VDC (surge 5A)
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature -40°C to +75°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 200 events
LED Indicators Power, Fan Run (8x green), Over-Temp Alarm, Fallback Active, Bus Fault

Advantages and Distinctive Features

  • 24-Bit Ultra-High Precision ADC: ±0.5°C accuracy for precise thermal management.

  • 3A Solid-State Outputs: 50% improvement over the base 2A rating—drives larger DC fans.

  • Extended Environmental Tolerance: -40°C to +75°C with 5g vibration resistance.

  • Onboard Temperature Threshold Logic: Autonomous ON/OFF fan control during backplane communication loss.

  • Silent, Maintenance-Free Operation: Unlimited switching cycles with no contact wear.

  • 200-Event Fault Log: Stores temperature alarms and fallback events.


Typical Application Fields

  • Offshore Oil & Gas Platforms: Extreme temperature and vibration environments.

  • Desert Power Plants: 75°C upper limit.

  • Arctic Compressor Stations: -40°C low-temperature tolerance.

  • DC Fan-Only Cabinets: Where tachometer feedback is not required.

  • Remote Unstaffed Stations: Autonomous fallback logic ensures cooling during communication loss.


Comparison with Related Models

Feature DS3800NGRD1E1D DS3800NGRD1B1A DS3800NGRD (Base) DS3800NFMC1E1C
Output Current 3A 2A 2A 3A
T/C Inputs 8 8 8 4
ADC Resolution 24-bit (±0.5°C) 16-bit (±1°C) 12-bit (±2°C) 24-bit (±0.5°C)
Onboard Logic Yes (threshold) No No Yes (threshold + averaging)
Operating Temp -40°C to +75°C 0°C to +60°C 0°C to +60°C -40°C to +75°C
Vibration 5g RMS 1g RMS 1g RMS 5g RMS
Fault Log 200 events Basic Basic 200 events
Cost High Low-Medium Low High

Selection Recommendations

  • Choose the DS3800NGRD1E1D if:

    • Your fans are DC-powered (24V or 48V) with current draw ≤3A.

    • You do not require tachometer feedback.

    • You want ultra-precise temperature monitoring (±0.5°C).

    • You need autonomous fallback cooling during CPU communication loss.

    • Your installation is in extreme environments (-40°C to +75°C) with high vibration.

  • Choose the DS3800NFMC1E1C if: You need 3A outputs, 24-bit ADC, and adaptive averaging but can accept 4 thermocouple inputs.

  • Choose the DS3800NGRD1B1A if: You need 2A outputs with 16-bit ADC in a climate-controlled environment.

  • Choose the base DS3800NGRD if: You need 2A outputs without improved accuracy or onboard logic.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap. Static damage to the 24-bit ADC degrades accuracy to >3°C.

  • DC Polarity: Solid-state outputs are DC-only and polarity-sensitive. Reverse polarity destroys the output MOSFET.

  • Voltage Limit: Do not exceed 48VDC—AC voltages cause catastrophic failure.

  • Current Derating: At 75°C, derate to 2.2A per output. For multiple channels active, reduce total load by 10% per channel.

  • No Tachometer Inputs: Do not connect speed sensors.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • Fallback Configuration: Thresholds must be configured via Mark V software. If not configured, the board defaults to 100% fan speed.

  • CPU Compatibility: Revision E firmware requires Mark V CPU firmware v5.0 or higher for full 24-bit ADC functionality and autonomous logic. For v4.x, the board reverts to 16-bit mode with no onboard logic.

  • Power Supply: Draws 3.8A on +5V rail—verify sufficient capacity.

A-B 1769-IM12
AB 1746-OB8
AB 1771-OBD

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NGRD1E1D”

Your email address will not be published. Required fields are marked *