GE DS3800NGRC1H1G

¥999.00

The DS3800NGRC1H1G is the ultimate flagship of the “NGRC” family, combining the highest relay current with next-generation AI, cyber-hardening, and extreme temperature tolerance. The suffix “1H1G” indicates Revision H firmware with AI-driven predictive thermal modeling24-bit ADC (±0.5°C accuracy), extended temperature components (-40°C to +85°C), military-grade vibration tolerance (5g RMS), 10A mechanical relay outputs8 thermocouple inputs8 RTD inputs (16 total temperature channels), no tachometer feedback, and redundant backplane communication paths

Category:

Description

Key Technical Parameters

Parameter Specification
Full Model DS3800NGRC1H1G
Power Supply +5V DC @ 5.8A, +15V DC @ 1.4A, -15V DC @ 1.0A
Temperature Inputs 8 T/C + 8 RTD = 16 total (24-bit ADC, ±0.5°C / ±0.3°C)
Fan Outputs 8 mechanical relays, 10A continuous @ 250VAC/30VDC (surge 20A)
Tachometer Inputs None
Communication Dual-redundant backplane with AES-256 encryption
Operating Temperature -40°C to +85°C
Vibration Resistance 5g RMS (MIL-STD-810G)
Fault Log 1000 events
LEDs Power, Fan Run (8x), RTD Fault, Relay Degradation, AI Active, Self-Heal Active, Redundant Path Active, Secure Comms Active, Over-Temp, Bus Fault

Advantages and Distinctive Features

  • 10A Mechanical Relays: Highest current capacity in the “NGRC” family—supports 1.5HP AC fans.

  • 16 Total Temperature Channels (8 T/C + 8 RTD): Supports mixed sensors or redundant monitoring.

  • AI-Driven Predictive Thermal Modeling: Deep learning predicts thermal events 20 minutes ahead with 97% accuracy.

  • Self-Healing Diagnostics: Automatic relay reset after transient faults (up to 3 resets/24hrs).

  • Redundant Backplane Communication: Dual paths with automatic failover (<50ms).

  • Cyber-Hardened: AES-256 encrypted backplane communication.

  • Extended +85°C Operation: Exceeds standard +75°C limit.

  • Predictive Relay Maintenance: Real-time contact resistance monitoring.

  • RTD Fault Detection: Continuous monitoring for open/short/lead-wire degradation.


Typical Application Fields

  • Extreme Desert Solar-Thermal Plants: +85°C ambient environments.

  • Engine Rooms and Turbine Enclosures: High-temperature, high-vibration areas.

  • Offshore Oil & Gas Platforms: Extreme conditions with AI-driven cooling.

  • Nuclear Auxiliary Turbines: High reliability with redundant communication.

  • Critical Infrastructure: Where cyber-security and predictive maintenance are mandatory.


Comparison with Related Models

Feature DS3800NGRC1H1G DS3800NGRC1H1F DS3800NGRA1L1E
Relay Current 10A 8A 10A
T/C + RTD 8 + 8 = 16 8 + 8 = 16 8 + 8 = 16
ADC 24-bit (±0.5°C) 24-bit (±0.5°C) 24-bit (±0.5°C)
AI Modeling Yes Yes Yes
Self-Healing Yes Yes Yes
Redundant Comms Yes Yes Yes
Cyber-Hardening Yes Yes Yes
Operating Temp -40°C to +85°C -40°C to +85°C -40°C to +85°C
Tach Inputs None None 2
Fault Log 1000 events 1000 events 2000 events
Cost Ultra-Premium+++ Ultra-Premium++ Ultra-Premium++++

Selection Recommendations

  • Choose the DS3800NGRC1H1G if:

    • You need 10A relay outputs for large AC fans.

    • You require 16 temperature channels (T/C + RTD).

    • You want AI modeling, self-healing, redundant comms, and cyber-hardening.

    • Your installation operates in extreme heat up to +85°C.

    • You do not require tachometer feedback.

  • Choose the DS3800NGRA1L1E if: You need 10A relays, 16 temperature channels, tachometer feedback, and 2000-event logging.

  • Choose the DS3800NGRC1H1F if: You need 8A relays with the same features but lower current capacity.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • RTD Wiring: Use 3-wire Pt100 RTDs—all three wires must be connected.

  • Relay Derating: For inductive fan motors, derate from 10A to 8A.

  • Redundant Paths: Both backplane paths must be connected for full fault tolerance.

  • Self-Healing: Enabled by default; disables after 3 resets per channel per 24hrs.

  • AI Learning: 72-hour initial learning—do not interrupt power.

  • Cyber-Hardening: AES-256 encryption must be enabled via Mark V software.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Compatibility: Requires Mark V CPU firmware v8.0 or higher for full features.

  • Power Supply: Draws 5.8A on +5V rail—mandatory power supply upgrade for most installations.

SCHNEIDER LV429637
SCHNEIDER 140CPS12400
A-B 1746-OG16

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NGRC1H1G”

Your email address will not be published. Required fields are marked *

Post comment