GE DS3800NGRC

¥999.00

The DS3800NGRC is a Fan/Exhaust Control board from General Electric’s Mark V Speedtronic™ series. This board features mechanical relay outputs with no tachometer feedback capability—placing it in the basic relay-based category. The DS3800NGRC provides 8 mechanical relay outputs (5A) and 8 thermocouple input channels.

The “NGRC” designation indicates a board optimized for higher-current relay-based fan control with full temperature monitoring, similar to the “NGRA” series, but with a distinct component baseline. The 5A relay rating makes it suitable for larger AC fans or multiple loads per channel. It relies entirely on the Mark V CPU for control logic.

Category:

Description

Key Technical Parameters

Parameter Specification
Manufacturer General Electric (GE)
Series Mark V (Speedtronic)
Full Model DS3800NGRC
Power Supply +5V DC @ 3.2A, +15V DC @ 0.5A, -15V DC @ 0.3A
Temperature Inputs 8 differential thermocouple channels (12-bit ADC, ±2°C accuracy)
Fan Outputs 8 mechanical relays, 5A continuous @ 115VAC/30VDC (surge 10A)
Tachometer Inputs None
Communication Mark V proprietary parallel backplane bus
Operating Temperature 0°C to +60°C
LED Indicators Power, Fan Run (8x), Over-Temp Alarm, Backplane Active

Advantages and Distinctive Features

  • 5A Mechanical Relays: The DS3800NGRC delivers 5A continuous (10A surge), suitable for 1/2 HP AC fans or multiple DC fans in parallel.

  • AC/DC Output Capability: Switches both AC and DC loads.

  • Full 8 Thermocouple Inputs: Comprehensive zone-by-zone temperature monitoring.

  • Complete Galvanic Isolation: 2500V isolation between control logic and fan power.

  • Simple, CPU-Dependent Operation: No onboard logic—cost-effective and easy to troubleshoot.


Typical Application Fields

  • Climate-Controlled Indoor Installations: 0°C to +60°C range.

  • Turbine Cabinets with Large AC Fans: Where 5A relay capacity is required.

  • High-Surge Fan Applications: Mechanical relays handle startup surges.

  • Budget-Conscious Applications: Cost-effective without tachometer feedback.


Comparison with Related Models

Feature DS3800NGRC DS3800NGRA DS3800NGDC DS3800NFEE
Relay Current 5A 5A 3A 3A
Tach Inputs None None None None
T/C Inputs 8 8 8 8
ADC Resolution 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C) 12-bit (±2°C)
Onboard Logic No No No No
Operating Temp 0°C to +60°C 0°C to +60°C 0°C to +60°C 0°C to +60°C
Cost Medium Medium Low Low

Selection Recommendations

  • Choose the DS3800NGRC if:

    • You need 5A mechanical relay outputs (AC or DC).

    • You do not require tachometer feedback.

    • You have a climate-controlled environment (0°C to +60°C).

    • You need 8 temperature sensors.

    • The Mark V CPU handles all control logic.

  • Choose the DS3800NGRA if: You need similar functionality but prefer the “NGRA” component revision (verify compatibility).

  • Choose the DS3800NGDC or DS3800NFEE if: You need 3A relays at lower cost.


Critical Precautions

  • ESD Protection: Always wear a grounded wrist strap.

  • Relay Contact Wear: Rated for 100,000 operations at 5A.

  • Inductive Load Derating: For inductive fan motors, derate to 3.5A or use external RC snubbers.

  • No Tachometer Inputs: Do not connect speed sensors.

  • No Hot-Swap: Always depower the rack before insertion/removal.

  • Slot Assignment: Install in slots 8–10 (auxiliary I/O).

  • CPU Dependency: If backplane communication is lost, the board defaults to 100% fan speed.

  • Firmware Compatibility: Compatible with all Mark V CPU firmware versions (v3.x and above).

GE IC693MDL741
ABB TU531
SCHNEIDER 140CPS12400

Reviews

There are no reviews yet.

Be the first to review “GE DS3800NGRC”

Your email address will not be published. Required fields are marked *

Post comment