Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark V (Speedtronic) |
| Full Model | DS3800NFLA |
| Power Supply | +5V DC @ 3.0A, +15V DC @ 0.5A, -15V DC @ 0.3A (via backplane) |
| Temperature Inputs | 8 differential thermocouple channels (Type J/K/T, 12-bit ADC) |
| RTD Inputs | None |
| Fan Outputs | 8 mechanical relays, 3A continuous @ 115VAC or 30VDC (surge 5A for 100ms) |
| Tachometer Inputs | 2 high-speed pulse channels (up to 10 kHz) for fan speed feedback |
| Communication | Mark V proprietary parallel backplane bus |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| LED Indicators | Power (green), Fan Run (8x amber), Tach Fail (red x2), Over-Temp Alarm (red), Backplane Active (yellow) |
Advantages and Distinctive Features
-
Mechanical Relays with Tachometer Feedback: The DS3800NFLA uniquely combines 3A mechanical relay outputs with 2 tachometer input channels—allowing the CPU to verify fan operation while benefiting from relay isolation and high surge tolerance.
-
AC/DC Output Capability: Unlike solid-state “NFIA” boards (DC-only), the DS3800NFLA can switch both AC and DC fan loads, providing greater flexibility for mixed cabinet installations.
-
High Surge Current Handling: Mechanical relays on the DS3800NFLA handle 5A surges, making them suitable for fan motors with high startup currents.
-
Complete Galvanic Isolation: Relay outputs provide 2500V isolation between the control logic and fan power circuits—superior to solid-state designs for noise immunity.
-
Simple, CPU-Dependent Operation: Like the base DS3800NFIB, the DS3800NFLA relies entirely on the Mark V CPU for control logic, with no onboard setpoint storage. This keeps the board simple and cost-effective.
Typical Application Fields
-
Turbine Cabinets with Mixed AC/DC Fans: Where both AC and DC fans are present and speed monitoring is required.
-
Safety-Critical Cooling Systems: Applications where fan failure must be detected immediately—the DS3800NFLA provides tachometer feedback for this purpose.
-
High-Inrush Fan Applications: Mechanical relays handle startup surges better than solid-state alternatives.
-
Retrofit from NFEE Boards: Upgrading to the DS3800NFLA adds tachometer monitoring without changing the relay output type.
-
Industrial Environments with High EMI: Mechanical relays provide superior isolation in electrically noisy environments.
Comparison with Related Models
| Feature | DS3800NFLA | DS3800NFEE (Base) | DS3800NFIA | DS3800NFEC1B1B |
|---|---|---|---|---|
| Output Type | Mechanical relay (AC/DC) | Mechanical relay (AC/DC) | Solid-state (DC only) | Solid-state (AC/DC) |
| Output Current | 3A | 3A | 2A | 2A |
| Tachometer Inputs | 2 channels | None | 2 channels | 2 channels |
| Onboard Logic | No (CPU-dependent) | No | No | Yes (PID-based) |
| ADC Resolution | 12-bit (±2°C) | 12-bit (±2°C) | 16-bit (±2°C) | 16-bit (±1°C) |
| AC Fan Capability | Yes | Yes | No | Yes |
| Operating Temp | 0°C to +60°C | 0°C to +60°C | 0°C to +60°C | -20°C to +65°C |
| Fallback Mode | Full speed (100%) | Full speed (100%) | Full speed (100%) | Full speed (100%) |
| Cost (Used) | Medium | Low | Medium-Low | High |
Selection Recommendations
-
Choose the DS3800NFLA if:
-
Your fans require mechanical relay outputs (AC or DC) with high surge handling.
-
You need tachometer feedback to verify fan operation.
-
You have a climate-controlled environment (0°C to +60°C).
-
The Mark V CPU handles all control logic (no onboard setpoints required).
-
You want a cost-effective hybrid solution without advanced firmware features.
-
-
Choose the DS3800NFEE if: You need relay outputs but do not require tachometer feedback.
-
Choose the DS3800NFIA if: You prefer solid-state DC outputs with tachometer feedback.
-
Choose the DS3800NFEC1B1B if: You need onboard PID control, AC/DC solid-state outputs, and extended temperature range.
Critical Precautions
-
ESD Protection: The DS3800NFLA contains sensitive ADC components. Always wear a grounded ESD wrist strap.
-
Relay Contact Wear: Mechanical relays on the DS3800NFLA are rated for 100,000 operations at 3A. For frequent cycling applications, consider derating or using solid-state alternatives.
-
Tachometer Wiring: Use shielded twisted-pair cable for tachometer signals. Connect the shield to the DS3800NFLA‘s designated shield terminal. Keep tach wiring separate from fan power cables.
-
Inductive Load Derating: The 3A rating applies to resistive loads. For inductive fan motors, derate to 2A or use an external RC snubber across each relay output.
-
No Hot-Swap: Always depower the Mark V rack before inserting or removing the DS3800NFLA.
-
Slot Assignment: Install in auxiliary I/O slots (typically slots 8–10). Do not install in CPU or analog input slots.
-
CPU Dependency: Since the DS3800NFLA has no onboard logic, the Mark V CPU must process tachometer feedback and send fan ON/OFF commands. If backplane communication is lost, the board defaults to 100% fan speed—tachometer monitoring will be disabled in fallback mode.
-
Firmware Compatibility: The DS3800NFLA has minimal firmware requirements and is compatible with all Mark V CPU firmware versions (v3.x and above). No specific CPU upgrade is needed for basic functionality.