Description
Technical Specifications
-
Product Type: Digital Voltage Reference & Calibration Board
-
Part Number: DS3800DVRC
-
Manufacturer: General Electric (GE)
-
System Compatibility: GE Speedtronic Mark IV Turbine Control Systems
-
Reference Outputs: 4 precision voltage references (±1V, ±5V, ±10V, and 0-10V)
-
Accuracy: ±0.01% of full scale at 25°C; ±0.005% per °C drift
-
Temperature Stability: < 5ppm/°C (typical)
-
Long-Term Stability: < 50ppm/year
-
Load Regulation: < 0.005% for 0 to 10mA load
-
Line Regulation: < 0.001% for ±10% input variation
-
Protection: Short-circuit protected outputs
-
Isolation: 1500Vrms isolation from backplane
-
Temperature Range: 0°C to +60°C
-
MTBF: > 250,000 hours (MIL-HDBK-217F)
Key Features & Advantages
-
High-Precision References: The GE DS3800DVRC provides extremely stable reference voltages with ±0.01% accuracy, essential for calibrating the Mark IV’s 12-bit analog-to-digital converters.
-
Multiple Reference Values: Offers four commonly used reference voltages (±1V, ±5V, ±10V, 0-10V), covering the full input range of most Mark IV analog boards.
-
Low Temperature Drift: < 5ppm/°C ensures calibration remains valid across the operating temperature range of the turbine control cabinet.
-
Long-Term Stability: < 50ppm/year minimizes the need for frequent recalibration.
-
Short-Circuit Protection: Protected outputs prevent damage during calibration setup or accidental shorts.
-
Diagnostic LEDs: Front-panel LEDs indicate reference output status and fault conditions.
-
External Access: The GE DS3800DVRC provides test points for external voltmeters, enabling verification of reference accuracy during routine maintenance.
Typical Application Cases
-
Analog Input Calibration: The GE DS3800DVRC provides reference voltages for calibrating the DS3800DVIA voltage input boards, ensuring accurate field signal readings.
-
Analog Output Verification: Used to verify the accuracy of analog output boards (e.g., servo driver boards) by comparing output against the reference.
-
System Diagnostics: During troubleshooting, the GE DS3800DVRC helps isolate faulty boards by providing a known-good signal source.
-
Preventive Maintenance: Used during annual maintenance to check and adjust the calibration of all analog boards in the Mark IV rack.
-
Commissioning: The GE DS3800DVRC is essential during initial startup to verify all analog channels meet specifications before turbine operation.
Competitive Comparison
| Feature | GE DS3800DVRC | External Voltage Calibrator |
|---|---|---|
| Integration | Rack-mounted, dedicated to Mark IV | Portable, requires manual connection |
| Reference Values | ±1V, ±5V, ±10V, 0-10V | User-selectable (wide range) |
| Accuracy | ±0.01% | ±0.001% to ±0.01% (model-dependent) |
| Temperature Stability | < 5ppm/°C | < 1ppm/°C to < 10ppm/°C |
| Convenience | Always ready, no setup required | Requires setup and teardown |
| Traceability | Factory-calibrated; not NIST-traceable | Often NIST-traceable |
| Compatibility | Direct connection to Mark IV backplane | Requires test leads and adapters |
The GE DS3800DVRC is less accurate than high-end laboratory calibrators but offers the convenience of being permanently installed and immediately available for routine calibration and troubleshooting.
Selection Guidelines & Precautions
-
Reference Verification: Before using the GE DS3800DVRC, verify its outputs with a calibrated external voltmeter to ensure accuracy. If drift is observed, the board may require factory recalibration.
-
Load Conditions: The GE DS3800DVRC provides accurate references only when the load current is below 10mA. For higher loads, use an external buffer amplifier.
-
Temperature: Allow the GE DS3800DVRC to stabilize for at least 30 minutes after power-up before performing critical calibrations, as initial warm-up drift may affect accuracy.
-
Short-Circuit: While the GE DS3800DVRC outputs are short-circuit protected, prolonged shorting may degrade accuracy over time.
-
Calibration Interval: GE recommended recalibration of the GE DS3800DVRC every 2 years. For sites without internal calibration capability, send to a qualified calibration lab.
-
ESD Handling: Use ESD-safe practices; contains precision reference components sensitive to static discharge.
-
Sourcing: Obsolete. Request functional test report including:
-
All 4 reference outputs verified for accuracy (±0.01%)
-
Temperature drift test (5ppm/°C max)
-
Load regulation test (0.005% max)
-
Output isolation verification
-
Short-circuit protection test
-
-
Spare Strategy: Keep one spare GE DS3800DVRC on-site if you perform regular analog board calibrations. For sites without a calibration lab, the board is essential for maintaining system accuracy.
Let me know if you have another model to analyze.