Description
Technical Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Series | Mark V / Mark VIe |
| Channels | 16 differential |
| Input Range | -10 mV to +100 mV (Type J/K/T/E) |
| Cold Junction | Single onboard sensor with enhanced linearization |
| Isolation | 1500V AC |
| Accuracy | ±0.08% at 25°C, ±0.15% across full temperature range |
| Sampling | 10 Hz sequential |
| Operating Temp | -30°C to +65°C |
| Storage Temp | -40°C to +85°C |
| Mounting | VME rack |
| Suffix “G1AEE” | Enhanced accuracy + G1 wiring + “S” performance optimizations + basic diagnostics (open/short only) + “EE” premium coating (high-grade urethane or silicone blend offering excellent moisture barrier, moderate-to-high solvent resistance, and good chemical protection) |
Key Features
-
Enhanced accuracy – ±0.08% for high-precision temperature monitoring
-
“S” performance optimizations – improved thermal stability, faster transient response, and enhanced noise rejection compared to standard “P” variants
-
Faster sampling – 10 Hz for responsive monitoring
-
“EE” premium coating – excellent moisture resistance and moderate-to-high chemical/solvent protection; suitable for harsh environments with chemical exposure
-
Improved cold-junction compensation – stable readings across ambient variations
-
Basic self-diagnostics – open-circuit and short-circuit detection per channel
-
Simple swap – no firmware changes required in most Mark V systems
-
LED status per channel + board health
-
Backward compatible with Mark V and Mark VIe (hot-swap only on VIe Rev D+)
Applications
-
Chemical processing plants – premium coating protects against solvent/fume exposure while “S” optimizations ensure stable readings
-
Coastal power plants with heavy salt spray – excellent moisture barrier with enhanced performance
-
Paper and pulp mills – harsh chemical environments with humidity and heat
-
Food processing with aggressive cleaning agents – resistance to caustic cleaners
-
Gas turbine EGT monitoring – tighter accuracy with optimized performance for combustion control in corrosive environments
-
Compressor performance monitoring – high-precision data with noise rejection for reliable readings
Comparison with Competitors
| Feature | DS200TCPSG1AEE |
ABB TTH300 | Siemens 7KG7750 |
|---|---|---|---|
| Channels | 16 | 8 | 12 |
| Accuracy | ±0.08% | ±0.10% | ±0.12% |
| Sampling | 10 Hz | 10 Hz (simultaneous) | 8 Hz (simultaneous) |
| Temp Range | -30°C to +65°C | -25°C to +65°C | -20°C to +60°C |
| Coating Type | “EE” premium | Standard acrylic | Standard acrylic |
| Moisture Resistance | Excellent | Moderate | Moderate |
| Chemical Resistance | Moderate to high | Low | Low |
| “S” Performance Optimizations | Yes | No | No |
| Hot-Swap | No (V) / Yes (VIe) | No | Yes |
| GE Native Integration | Yes | No | No |
Selection Tips
-
Choose the
DS200TCPSG1AEEif you need enhanced accuracy (±0.08%), specialized “S” performance optimizations, and premium coating protection in a G1 cabinet – ideal for warm, chemically aggressive environments where signal stability is critical -
For the same features with standard coating (less protection), consider
DS200TCPSG1A -
For severe chemical/corrosion exposure with similar specs, upgrade to
DS200TCPSG1AJE(military-grade) orDS200TCPSG1ATF(PTFE) if available -
For extended diagnostics (drift/degradation) with similar coating, consider
DS200TCPDG1BEC(lower accuracy at ±0.12% for G1B variant) -
Verify existing wiring is 2-wire standard – G1-series terminal mapping applies
-
Source refurbished units with coating inspection verification and “S” performance test validation
Precautions
-
ESD sensitive – use wrist strap
-
Power down for Mark V removal (no hot-swap)
-
Torque terminals to 0.5 N·m max
-
Do not exceed -30°C to +65°C operating range
-
Avoid damaging the coating – scratches compromise protection
-
Use isopropyl alcohol only for cleaning – confirm solvent compatibility with GE documentation for “EE” coating; it resists many solvents but avoid acetone/MEK
-
Calibrate every 24 months – accuracy spec depends on valid calibration
-
Ground shields only at the board end
-
Verify thermocouple type – optimized for J/K (T/E reduces accuracy to ±0.15%)
-
Label clearly – mark as “G1AEE – S-OPTIMIZED/PREMIUM COAT” to ensure proper handling
-
Confirm “S” specifications with your supplier – request detailed test documentation for performance optimizations

3RW4055-2BB44
ABB SPDSO14
HONEYWELL CC-PCNT01
SCHNEIDER 140MSB10100


Reviews
There are no reviews yet.