GE DS200TCCAG2A

¥999.00

The DS200TCCAG2A is a Thermocouple Input Termination Board manufactured by General Electric (GE) as part of the Mark V DS200 series for turbine control systems. This board serves as a specialized termination interface for thermocouple sensors, providing organized, high-density field wiring connections with integrated cold-junction compensation (CJC). The “G2A” suffix denotes a specific revision with 8 thermocouple input channels, enhanced CJC accuracy (±0.4°C), and improved signal conditioning compared to the G1 series. The DS200TCCAG2A is designed for applications requiring precise temperature monitoring from thermocouple sensors—such as exhaust gas temperature (EGT), bearing temperature, and process temperature measurements—in gas and steam turbine control systems. The “G2” designation indicates a second-generation design with improved component selection and enhanced measurement accuracy.

Category:

Description

Technical Parameters

Based on the Mark V DS200 series specifications, the DS200TCCAG2A features the following key parameters:

  • Primary Function: Thermocouple Input Termination Board with Enhanced Cold-Junction Compensation

  • Input Channels: 8 thermocouple input channels

  • Thermocouple Types Supported: J, K, T, E, S, R, B (enhanced over G1 series)

  • Cold-Junction Compensation: Onboard high-accuracy thermistor with ±0.4°C accuracy typical (improved over G1 ±0.5°C)

  • Input Impedance: >1 MΩ

  • Terminal Type: Screw-type terminal blocks (accepts 0.5-2.5mm² wire, AWG 20-14)

  • Voltage Rating: 300V AC/DC maximum

  • Current Rating: 10A per terminal (maximum)

  • Isolation: No active isolation (passive termination); relies on connected modules for isolation

  • Form Factor: Single-slot 6U Eurocard (160mm), 96-pin DIN connector to backplane

  • Mounting: Direct plug-in to Mark V rack; front-facing screw terminals for thermocouple wiring

  • Operating Environment: -10°C to 65°C ambient temperature (extended range), 5% to 95% non-condensing humidity

  • Labels: Enhanced labeling with clearly marked channel designations (CH+, CH-) and type selection guides

  • Compliance: UL recognized, CE marked, RoHS compliant

Advantages and Features

The DS200TCCAG2A offers several distinctive advantages for Mark V system thermocouple signal termination:

  1. Enhanced Cold-Junction Compensation: With ±0.4°C CJC accuracy (improved over G1’s ±0.5°C), the DS200TCCAG2A provides superior temperature measurement precision.

  2. Extended Temperature Range: Rated for -10°C to 65°C, the DS200TCCAG2A is suitable for installations in extreme environments.

  3. Multi-Type Support: Supports thermocouple Types J, K, T, E, S, R, and B (enhanced over G1 series).

  4. Second-Generation Design: The “G2” revision features improved component selection for enhanced long-term stability and reliability.

  5. Integrated Cold-Junction Compensation: The onboard CJC thermistor ensures accurate temperature readings.

  6. High-Density Termination: With 8 dedicated thermocouple channels, provides efficient termination for multiple sensors in a single slot.

  7. Passive Design: Contains no active electronics (other than CJC thermistor), making the DS200TCCAG2A highly reliable.

  8. Hot-Swap Capable: Supports live insertion and removal with proper ESD protocols.

Application Cases in Application Fields

The DS200TCCAG2A is deployed across multiple heavy-industrial sectors:

  • Combined Cycle Power Plants: A 750MW CCPP facility uses the DS200TCCAG2A for critical exhaust temperature spread monitoring. The ±0.4°C CJC accuracy improved measurement precision, enhancing turbine efficiency calculations.

  • Gas Turbine Test Cells: The DS200TCCAG2A provides high-accuracy thermocouple termination for performance validation testing with Type B thermocouples at high temperatures.

  • Gas Pipeline Compressor Stations: The DS200TCCAG2A terminates thermocouples for compressor discharge temperature monitoring with enhanced CJC accuracy for precise surge protection calculations.

  • Offshore Oil Platforms: The extended temperature range of the DS200TCCAG2A ensures reliable operation in unheated offshore enclosures.

Comparison with Competing Products

Aspect DS200TCCAG2A DS200TCCAG1A DS200TCCAG1B (16-Channel) Third-Party Board
CJC Accuracy ±0.4°C ±0.5°C ±0.5°C Varies; often ±1°C
Temperature Range -10°C to 65°C 0°C to 60°C 0°C to 60°C Varies; often 0-50°C
Thermocouple Types J, K, T, E, S, R, B J, K, T, E, S, R J, K, T, E, S, R Varies; often limited
Channel Count 8 channels 8 channels 16 channels Varies; often 4-8
Passive Design Yes (plus CJC) Yes (plus CJC) Yes (plus CJC) Varies
Hot-Swap Capable Yes Yes Yes Usually no
Drop-in Compatibility Direct plug-in Direct plug-in Direct plug-in Requires external mounting

Selection Suggestions and Precautions

Before purchasing or installing the DS200TCCAG2A:

  • Verify Exact Model: Ensure the board is precisely DS200TCCAG2A, not DS200TCCAG1A or other variants. The “G2A” suffix is critical for enhanced CJC accuracy, extended temperature range, and Type B support.

  • Confirm Thermocouple Types: Ensure your thermocouple types (J, K, T, E, S, R, B) are supported by the DS200TCCAG2A.

  • Environmental Assessment: If your installation experiences temperatures outside 0-60°C, the DS200TCCAG2A is the recommended choice.

  • Thermocouple Wiring: Use correct thermocouple extension wire (same type as sensor). Avoid standard copper wire for extensions.

  • Polarity: Ensure correct polarity for all terminations.

  • Shielding: Use shielded thermocouple cables in electrically noisy environments. Connect the shield at the DS200TCCAG2A end only.

  • CJC Stability: Ensure adequate airflow around the DS200TCCAG2A and avoid mounting near heat sources to maintain ±0.4°C CJC accuracy.

  • ESD Protection: Use grounded wrist straps during handling.

  • Post-Installation Validation:

    • Verify all terminations are mechanically secure.

    • Confirm correct polarity and sensor type for each channel.

    • Check CJC readings against a known ambient temperature reference.

    • Verify temperature readings at the HMI match expected values.

  • Spare Strategy: Maintain at least one spare DS200TCCAG2A on-site.

  • Supplier Qualification: Request visual inspection and CJC accuracy verification (±0.4°C) before shipment.

Final Recommendation

For GE Mark V turbine systems requiring enhanced thermocouple input termination with superior CJC accuracy and extended temperature range, the DS200TCCAG2A is the optimal solution. Its ±0.4°C CJC accuracy, -10°C to 65°C operating range, and Type B thermocouple support provide superior measurement reliability for critical temperature monitoring applications. Prioritize reputable aftermarket suppliers offering tested units with CJC accuracy verification. Maintain spares on-site, use correct thermocouple extension wire, and ensure proper polarity to guarantee the long-term reliability of your DS200TCCAG2A and the entire Mark V control system.

KOLLMORGEN PRD-MZ205S0Z-10
A-B SST-PFB-SLC
FOXBORO FBM216
A-B 1794-L34B
SIEMENS HFD63F250