Description
Key Technical Parameters
| Parameter | Specification |
|---|---|
| Function | Power line interface, circuit breaker monitoring, and control output (high-density version) |
| Inputs | 16 digital inputs (24 VDC or 125 VDC selectable via jumpers) for breaker status, switch position, and auxiliary contacts |
| Outputs | 8 digital outputs (dry contact relays, form C, rated 5A @ 250 VAC / 30 VDC) for breaker trip/close commands and auxiliary control |
| Communication | Backplane interface to Mark V processor for status reporting and command execution |
| Isolation | Galvanic isolation (2,500 VAC) between field side and Mark V backplane |
| Input Filtering | Debounce filtering (programmable 5-50 ms) to prevent false triggering from contact chatter |
| Diagnostic Indicators | 16 LEDs (one per input) for status indication + 8 LEDs (one per output) for command state |
| Protection | Overvoltage protection on inputs, short-circuit protection on outputs, surge suppression (5kV) |
| Conformal Coating | None – standard industrial grade |
| Temp Range | 0 to +55°C ambient |
| Form Factor | 6U VME, 1-slot width (no adjacent slot clearance required) |
| Weight | 1.0 kg (approx. 2.2 lbs) |
Advantages & Core Features
-
High-density I/O capacity – With 16 inputs and 8 outputs, the DS200PLIBG2A provides double the capacity of the DS200PLIBG1A (8 inputs, 4 outputs), enabling monitoring and control of multiple breakers, tie switches, and auxiliary equipment from a single board. This reduces the number of boards required in the rack, saving valuable space in dense installations.
-
Selectable input voltage – Inputs are jumper-selectable for 24 VDC or 125 VDC, providing flexibility to interface with different plant control voltages without external signal converters.
-
Galvanic isolation – 2,500 VAC isolation protects the Mark V backplane and processor from voltage spikes and ground loops in the switchyard.
-
Programmable debounce filtering – Adjustable input filtering (5-50 ms) prevents false status changes from contact bounce or transient noise.
-
Dry contact relay outputs – Eight form C relays provide robust breaker trip/close commands, rated for 5A @ 250 VAC / 30 VDC – suitable for direct control of medium-voltage switchgear.
-
Status LEDs – 24 LEDs (16 inputs + 8 outputs) provide immediate visual indication of all I/O status, simplifying troubleshooting.
-
Compact 1-slot form factor – Despite the high-density I/O, the board fits in any standard Mark V slot without requiring adjacent empty space.
Application Cases
-
Complex switchyard with multiple breakers – A 500 MW combined-cycle plant with a dual-bus, dual-breaker switchyard uses the DS200PLIBG2A to monitor 12 circuit breakers, 4 disconnect switches, and 2 grounding switches. The 16 inputs and 8 outputs handle the entire breaker interface from a single board, saving rack space for other critical modules.
-
Offshore platform with limited rack space – A North Sea platform with a compact Mark V rack uses the DS200PLIBG2A to monitor and control the utility tie breaker, generator breaker, and emergency diesel generator breaker. The high-density I/O eliminates the need for a second breaker interface board.
-
Industrial co-generation facility – A chemical plant with multiple tie breakers and load-shedding schemes uses the DS200PLIBG2A to execute automatic transfer and islanding sequences.
-
Hydroelectric plant with multiple units – A dam facility uses the DS200PLIBG2A to interface with the main transformer breaker and auxiliary breakers for multiple turbine-generator units.
Comparison with Related Variants
| Feature | DS200PLIBG2A (High-Density) | DS200PLIBG1A (Base) | DS200PLIBG1ACA (Coated, Expanded) |
|---|---|---|---|
| Digital Inputs | 16 | 8 | 12 |
| Digital Outputs | 8 | 4 | 6 |
| Conformal Coating | No | No | Yes |
| Isolation Voltage | 2,500 VAC | 2,500 VAC | 2,500 VAC |
| Surge Protection | 5kV | 5kV | 6kV |
| Input Debounce | Programmable 5-50 ms | Programmable 5-50 ms | Programmable 5-50 ms |
| Temp Range | 0 to +55°C | 0 to +55°C | 0 to +60°C |
| LED Indicators | 24 | 12 | 19 |
| Slot Width | 1-slot | 1-slot | 1-slot |
| Availability | Rare (8-12 weeks) | Rare (6-10 weeks) | Extremely rare (12-16 weeks) |
| Cost | Moderate-high | Moderate-high | High |
| Best For | High-density breaker monitoring, space-constrained racks | Standard breaker monitoring | Harsh environment + expanded I/O |
Key Takeaway: The DS200PLIBG2A is the highest-density Mark V breaker interface board, offering 16 inputs and 8 outputs in a single 1-slot package. It is the ideal choice for complex switchyards or space-constrained racks where the base DS200PLIBG1A would require multiple boards. There is no conformally coated version of the G2A model – for harsh environments, you would need to balance density requirements with the coated but lower-density DS200PLIBG1ACA.
Selection Suggestions
-
Count required I/O – If your application requires more than 12 inputs or 6 outputs, the DS200PLIBG2A with 16 inputs and 8 outputs may allow you to use a single board instead of multiple base boards.
-
Assess environmental conditions – The DS200PLIBG2A has no conformal coating. For harsh environments (coastal, offshore, chemical), consider the coated DS200PLIBG1ACA (12 inputs, 6 outputs) or use additional protective measures with the G2A.
-
Verify input voltage – Select the appropriate jumper setting for 24 VDC or 125 VDC based on your plant’s switchgear auxiliary supply.
-
Confirm relay rating – Ensure the 5A @ 250 VAC rating is sufficient for your trip/close coils. For larger coils, external interposing relays may be required.
-
Check slot availability – Standard 1-slot Mark V position.
-
Procurement – The DS200PLIBG2A is rare. Purchase from reputable suppliers offering functional testing (all inputs/outputs verified, isolation tested). Lead times: 8-12 weeks.
-
Stock spares – Maintain one on-site spare for critical applications.
Important Precautions
-
Power down completely – De-energize rack before installation. Hot-swapping not supported.
-
ESD protection – Use wrist strap and anti-static mat.
-
Field wiring – Ensure field wiring is properly terminated and routed away from high-voltage cables. Use shielded cables for inputs if running in noisy environments.
-
Voltage selection – Verify jumper settings before applying field power. Incorrect voltage selection will damage the board.
-
Debounce configuration – Set debounce time based on contact characteristics (typical: 10-30 ms).
-
Relay contacts – Do not exceed 5A @ 250 VAC / 30 VDC ratings. For higher current loads, use interposing relays.
-
Cleaning – Use compressed air only. No liquids.
-
Storage – Store at 10-30°C, 20-50% RH. Rotate every 24 months.
Final Expert Recommendation
The DS200PLIBG2A is the highest-density Mark V breaker interface board, offering 16 inputs and 8 outputs in a compact 1-slot package. It is the definitive choice for installations requiring monitoring and control of multiple circuit breakers, disconnect switches, and grounding switches from a single board, particularly in space-constrained racks where multiple base boards would be impractical.
Select the DS200PLIBG2A when:
-
You need to monitor and control more than 12 breakers or auxiliary switches
-
You require more than 6 breaker trip/close outputs
-
Your rack is space-constrained and you want to minimize board count
-
You have a clean indoor environment (no conformal coating required)
However, there is no conformally coated version of the G2A model. For harsh environments, you must choose between:
-
The DS200PLIBG1ACA (coated, 12 inputs, 6 outputs) – if that capacity is sufficient
-
The DS200PLIBG2A with external protective measures (sealed enclosures, additional surge suppression) – if the higher density is essential
For most applications, the DS200PLIBG1A (8 inputs, 4 outputs) is sufficient for standard breaker monitoring. The DS200PLIBG2A should be reserved for complex switchyards, multi-breaker installations, or dense racks where space is at a premium.
When sourcing the DS200PLIBG2A, ensure functional testing of all inputs and outputs is performed. With proper installation and configuration, this board will provide years of reliable service as the high-density interface between your turbine control system and complex power distribution equipment.