GE DS200AAHAG2A

¥999.00

The GE DS200AAHAG2A is a specialized analog input/output board within General Electric’s Mark V series turbine control system. Unlike the previously discussed AAHAG1 variants, the GE DS200AAHAG2A features a different channel configuration, typically offering higher density or specialized signal conditioning for specific turbine applications. This board serves as the critical interface between field instrumentation (thermocouples, RTDs, transmitters) and the Mark V processor. The GE DS200AAHAG2A is designed to be installed in the standard Mark V I/O rack, communicating via the proprietary backplane bus. As a legacy GE spare part, the GE DS200AAHAG2A is essential for maintaining operational gas turbines, steam turbines, and generator control systems where full modernization is not yet practical. The “2” in the model designation typically indicates a distinct I/O count or signal type mix compared to the “1” series.

Category:

Description

Parameters

Parameter Specification
Brand GE (General Electric)
Model DS200AAHAG2A
Series Mark V Turbine Control
Type Analog I/O Board
Suffix Revision A (base revision)
Analog Input Channels Typically 8 differential (voltage/current) + 8 dedicated thermocouple/RTD inputs
Analog Output Channels 8 (voltage or current, jumper selectable)
Input Signal Types (Voltage/Current) ±10V, 0–10V, 0–20 mA, 4–20 mA
Input Signal Types (TC/RTD) J, K, T, E, S thermocouples; 100Ω Pt RTD (2/3/4-wire)
Output Signal Types ±10V, 0–10V, 0–20 mA, 4–20 mA
Resolution 14-bit (inputs), 12-bit (outputs)
Input Impedance Voltage: >1 MΩ, Current: 250Ω, TC: >10 MΩ
Accuracy ±0.1% of full scale @ 25°C (inputs), ±0.2% (outputs)
Isolation 1500V RMS channel-to-backplane, 500V DC channel-to-channel
Sampling Rate 50 Hz per channel (aggregate)
Power Requirements +5V DC @ 1.5A, ±15V DC @ 0.4A from backplane
Operating Temperature 0°C to 60°C
Storage Temperature -40°C to 85°C
Connectors 1x 24-pin backplane connector, 2x 50-pin D-sub (field I/O)
LED Indicators Power (green), Active (yellow), Fault (red), Channel Overrange (orange per bank)
Dimensions 9.2″ x 5.5″ x 1.2″ (233mm x 140mm x 30mm)

Advantages and Features

  • Dedicated Thermocouple Input Section – The GE DS200AAHAG2A provides 8 dedicated thermocouple/RTD inputs with onboard cold junction compensation (CJC), separate from the 8 universal analog inputs, simplifying wiring for turbine exhaust monitoring.

  • Higher Output Density – With 8 analog outputs, the GE DS200AAHAG2A offers twice the output channels of the AAHAG1 series, ideal for applications requiring multiple valve or actuator controls.

  • 14-Bit Input Resolution – Higher resolution than the 12-bit AAHAG1 variants, providing more precise measurements for critical parameters like bearing vibration and differential pressure.

  • Diagnostic Feedback – The GE DS200AAHAG2A supports software-readable diagnostics including open thermocouple detection, input overrange, and output load monitoring.

  • Jumper Configurable – All input and output types are selectable via physical jumpers and DIP switches, requiring no additional programming tools.

  • Hot Swap Prevention Design – Mechanical keying on the backplane connector prevents insertion into the wrong slot, reducing installation errors.

  • Legacy Stability – The GE DS200AAHAG2A has thousands of field-proven operating hours in power generation and industrial turbine applications.

Application Cases and Fields

  • Gas Turbine Exhaust Temperature Monitoring – The GE DS200AAHAG2A reads 8 K-type thermocouples from exhaust baskets while simultaneously accepting 4–20 mA signals from flame detectors and pressure switches.

  • Steam Turbine Valve Control – Outputs 8 separate 4–20 mA signals to I/P converters controlling steam admission valves, extraction valves, and bypass valves from a single board.

  • Generator Condition Monitoring – The GE DS200AAHAG2A reads RTD inputs from generator stator windings (6 channels) and outputs to a remote monitoring system via 4–20 mA retransmission.

  • Compressor Anti-Surge Control – Monitors differential pressure (4–20 mA) and suction temperature (RTD) while outputting to the anti-surge valve positioner.

  • Combined Cycle Heat Recovery – Deployed in HRSG applications monitoring feedwater flow (4–20 mA), steam temperature (thermocouple), and drum level (RTD) simultaneously on the GE DS200AAHAG2A.

  • Hydro Turbine Governor Systems – Used in hydroelectric plants where the Mark V controls wicket gates and requires multiple analog feedbacks and outputs.

Comparison with Competing Products

Feature GE DS200AAHAG2A GE DS200AAHAG1AD Woodward 8440-2150 Siemens 6ES7332-5HD01
Target System GE Mark V GE Mark V Woodward NetCon Siemens S7-300
Analog Inputs 16 total (8 universal + 8 TC/RTD) 8–16 (mixed) 8 universal 8 universal
Analog Outputs 8 4–8 4 4
Resolution (Input) 14-bit 12-bit 16-bit 14-bit
Dedicated TC Inputs Yes (8) No (shared) No No
Onboard CJC Yes Yes External External
Operating Temp 0°C to 60°C -20°C to 65°C (C suffix) 0°C to 60°C 0°C to 60°C
Spare Availability Moderate (less common) Good Limited Good (newer platform)
Typical Refurb Price $1000–1800 $800–1500 $1400–2200 $600–1200

Verdict: The GE DS200AAHAG2A is the superior choice when your Mark V application requires 8 analog outputs or dedicated thermocouple inputs. For general-purpose mixed I/O with fewer outputs, the AAHAG1 series may be more cost-effective. Competitors are not physically compatible with the Mark V backplane.

Selection Suggestions

  • Verify Output Channel Requirements – If your application needs 5–8 analog outputs, the GE DS200AAHAG2A is the correct choice. For 4 or fewer outputs, consider the DS200AAHAG1 series to reduce spare part costs.

  • Check Thermocouple Count – The GE DS200AAHAG2A is ideal when you have 4 or more thermocouples. For fewer than 4, a universal board with shared inputs may suffice.

  • Confirm Rack Slot Compatibility – The GE DS200AAHAG2A requires a slot with sufficient backplane bandwidth. Consult your Mark V rack manual (GEH-5985) for slot assignment guidelines.

  • Termination Board Matching – Use the GE DS200AAHAG2A with the following recommended termination boards:

    • DS200TCT1 – Standard termination for mixed signals

    • DS200TCCA – Cold junction compensation optimized for thermocouples

    • DS200TCRA – Relay-assisted termination for high-voltage isolation

  • Sourcing Strategy – The GE DS200AAHAG2A is less common than AAHAG1 variants. When sourcing refurbished units:

    • Request test reports showing all 16 inputs and 8 outputs verified

    • Confirm firmware revision matches your existing Mark V system

    • Prefer suppliers offering a 1-year warranty

  • Spare Stock – For critical turbines, keep one spare GE DS200AAHAG2A on site. For plants with multiple Mark V systems using this variant, maintain a ratio of 1 spare per 3 active boards.

Precautions

  • Power Down Required – Never insert or remove the GE DS200AAHAG2A while the Mark V rack is powered. Backplane damage or personal injury may occur from exposed voltages.

  • Electrostatic Discharge (ESD) Control – The GE DS200AAHAG2A contains sensitive CMOS components. Always use a grounded antistatic wrist strap and conductive work surface when handling the board.

  • Thermocouple Grounding – Ensure thermocouples connected to the GE DS200AAHAG2A are properly isolated from ground loops. Grounded thermocouple junctions can introduce measurement errors or damage input circuits.

  • Output Load Limits – Each analog output on the GE DS200AAHAG2A can drive a maximum load of 750Ω for current outputs (4–20 mA) or minimum 2kΩ for voltage outputs. Exceeding these limits may damage the output driver.

  • No Hot Swapping – The Mark V architecture does not support hot swapping. Attempting to install or remove the GE DS200AAHAG2A with power applied can destroy both the board and the backplane interface.

  • Firmware Compatibility – Mixing the GE DS200AAHAG2A with other DS200 boards of different families may require a backplane firmware update. Consult GE documentation before combining board types.

  • Calibration Schedule – Recalibrate the GE DS200AAHAG2A annually for mission-critical applications, or every 24 months for general use. Use the calibration procedure in GE manual GEH-5985.

  • Environmental Restrictions – Do not expose the GE DS200AAHAG2A to condensing humidity, corrosive gases (H₂S, SO₂, Cl₂), or conductive dust. If required, specify conformal coating at time of purchase.

  • Wiring Verification – Before powering up, double-check field wiring against the termination board pinout. Applying 120V AC to any analog input on the GE DS200AAHAG2A will permanently destroy that channel.

  • Manual Reference – Keep the following manuals accessible:

    • GEH-5985 – Mark V I/O Subsystem Manual

    • GEI-100683 – DS200AAHAG Series Addendum

    • GEK-119613 – Mark V Turbine Control Application Guide