Description
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Full Model | DS3800HXPC |
| Family | Speedtronic Mark IV / Mark V |
| Board Type | High-Speed Counter / Accumulator Input |
| Channels | 2–4 independent high-speed pulse inputs |
| Frequency Range | 0 – 20 kHz (jumper-configurable) |
| Input Signal | ±5V to ±30V (magnetic VR, proximity, TTL) |
| Isolation | Transformer/opto-isolated |
| Connectors | J1, J2, J3 (40-pin headers) |
| Power Supply | +5V / ±15V from Mark IV/V backplane |
| Operating Temp | 0°C to 60°C |
Advantages
-
High noise immunity – differential inputs with transformer isolation reject EMI in harsh turbine environments
-
Flexible sensor compatibility – configurable via jumpers for passive VR pickups or active proximity probes
-
Redundancy-ready – multiple channels support 2-out-of-3 voting for over-speed protection (SIL-3 rated with Mark V)
-
On-board diagnostics – continuous input health monitoring with fault flagging to the Mark V controller
-
HXPC base designation (specialized) – the X suffix indicates a custom or specialized variant that may include unique PLD firmware, non-standard component selections, or modified timing/counter resolution for specific turbine applications or OEM requirements
-
Field-proven – deployed in select GE turbine installations; MTBF >100,000 hours
Applications
-
GE Frame 5/6/7/9 gas turbines – speed feedback for custom or OEM-specific packages
-
Steam turbines – over-speed trip logic in specialized configurations
-
LM2500/LM6000 aeroderivative turbines – speed input for custom control schemes
-
Specialized or custom turbine packages – the HXPC base is likely used in applications requiring non-standard PLD timing, unique counter resolution, or specialized sensor interfacing not found in standard variants
vs. Competitors
| Feature | DS3800HXPC | Siemens FM350-1 | Woodward 9907-018 |
|---|---|---|---|
| Max Frequency | 20 kHz | 10 kHz | 30 kHz |
| Isolation | Transformer + Opto | Opto only | Opto only |
| Integration | GE Mark IV/V native | STEP 7/TIA | Standalone |
| Base Variant Specific | Yes (HXPC – custom) | N/A | N/A |
| SIL Rating | SIL-3 (with Mark V) | Not rated | SIL-2 |
The DS3800HXPC is the only direct drop-in replacement for GE systems requiring this specialized base variant; generic alternatives lack native backplane communication and the custom firmware/component configuration.
Selection Tips
-
Verify exact base model with extreme care – The DS3800HXPC is a specialized/custom variant. It is not interchangeable with DS3800HSCA, DS3800HSCC, DS3800HSCD, DS3800HSCG, DS3800HSCJ, DS3800HSCX, DS3800HSDD, DS3800HSGG, DS3800HSHA, DS3800HSHB, DS3800HSPC, DS3800HSQD, DS3800HSQE, DS3800HUMA, DS3800HUMB, DS3800HUMC, DS3800HVDB, DS3800HVDC, DS3800HXCA, DS3800HXFC, DS3800HXLA, DS3800HXMA, DS3800HXOD, or DS3800HXPA variants without explicit verification from GE documentation or your turbine OEM. The X designation typically means non-standard—do not substitute blindly.
-
Check for suffix additions – Many units have extended suffixes (e.g., DS3800HXPC1G1E). Confirm the full model number and PLD firmware version with your supplier.
-
Obtain PLD firmware details – The custom nature of the HXPC means PLD firmware is likely unique. Request the firmware version and verify compatibility with your Mark V application software.
-
Verify jumper settings – Configure W1–W8 to match your specific speed sensor type (VR or proximity) before installation.
-
Source from reputable refurbishers with traceability – Demand functional test reports, speed simulation verification, 72-hour burn-in, and confirmation of custom firmware/component configuration.
-
Stock a spare on-site – Given the custom nature, lead times may be longer (4–8 weeks); an on-hand spare is highly recommended.
-
Consult OEM documentation – Before purchasing, confirm with GE or your turbine OEM that the DS3800HXPC is the correct replacement for your specific system.
Critical Precautions
-
ESD protection mandatory – CMOS components are sensitive; use wrist straps and grounded workstations.
-
Power down before handling – Never insert or remove the DS3800HXPC with the Mark V rack energized—live insertion can damage the board and backplane.
-
Use shielded twisted-pair cabling – Single-point ground at the turbine terminal box only to avoid ground loops and induced noise.
-
Annual calibration – Adjust potentiometers (R1–R3) per GE manual GEI-100512 to maintain speed measurement accuracy.
-
Firmware alignment is critical – The custom HXPC firmware must match your Mark V application version. Mismatched firmware will cause communication faults or incorrect speed readings.
-
Storage – Keep spare units in anti-static bags in climate-controlled conditions (15–35°C, <60% humidity), away from strong magnetic fields.
Final Verdict
The DS3800HXPC is a specialized, mission-critical speed input board for GE Mark IV/V turbine systems, distinguished by its HXPC custom designation. Due to its non-standard nature, extreme care must be taken to verify PLD firmware, component configuration, and OEM compatibility before installation. Proper model matching, firmware alignment, careful handling, and routine calibration will ensure safe and reliable turbine speed control and over-speed protection.

A-B 802T-BPVE
Schneider LV525333
AB 1492GH100


Reviews
There are no reviews yet.