Description
Parameters
-
Output Type: 24V DC discrete (transistor, sourcing or sinking configurable)
-
Output Channels: 8 channels (typical for this series)
-
Output Voltage: 24V DC (nominal), 10–30V DC range
-
Output Current: 0.5A per channel (short-circuit protected)
-
Response Time: <0.5ms (high-speed logic capability)
-
Isolation: 2500V RMS optical isolation (channel-to-backplane)
-
Power: +5V DC @ 0.8A, +24V DC @ 0.3A (field power)
-
Diagnostics: Advanced onboard with LED status per channel, short-circuit protection, open-wire detection, and specialized output monitoring
-
Coating: Basic conformal coating (suffix A) – single-layer acrylic
-
Temp Range: 0°C to +60°C
-
Mounting: 6U VME Eurocard, single-slot
-
Compatibility: Mark IV backplanes and some VIe systems (with adapter)
Advantages & Features
-
Specialized configuration – unique timing, sequencing, or fault handling features for critical protection applications
-
Ultra-fast output response (<0.5ms) – designed for critical trip and protection logic
-
8-channel density provides sufficient outputs for specialized actuation needs
-
Flexible output configuration – channels can be set as sourcing or sinking via jumpers
-
Short-circuit protected outputs prevent damage from field wiring faults
-
Isolated channels protect the backplane from field wiring faults and surges
-
Basic A-grade coating provides light moisture and dust protection for indoor installations
-
Front-panel LEDs for per-channel status, fault, and output state indication
-
Compatible with Mark IV backplanes and some VIe systems (with adapter)
Application Cases
-
Specialized overspeed trip outputs – unique timing requirements for turbine overspeed protection
-
Flame detection outputs – fast fuel trip valve actuation with specialized fault handling
-
Emergency trip systems (ETS) – critical output actuation with advanced diagnostics
-
Turbine start-up sequencing – specialized timing requirements for starter and purge valves
-
Retrofit projects replacing specialized high-speed output boards in Mark IV systems
Competitor Comparison
-
vs. DS3800HLNA (standard A variant): Specialized configuration may offer unique features not available on HLNA – HLOA is for specialized applications
-
vs. DS3800HLNE (specialized E variant): Similar specialized configuration, but HLOA has A coating vs. E coating
-
vs. DS3800HLNF1D1B (D1/B variant): HLOA offers specialized configuration but lacks D1 firmware features – choose based on specialization vs. advanced diagnostics
-
vs. DS3800HHTB1D1D (relay output): HLOA offers significantly faster response (<0.5ms vs. 12ms) – better for high-speed protection
-
vs. DS3800HLCB (hybrid high-speed I/O): HLOA is output-only with faster response – better for critical protection outputs
-
vs. ABB DSDI series: Similar high-speed discrete capability, but GE offers specialized configuration and better Mark IV integration
-
vs. Siemens 6ES7 series: Similar functionality, but GE offers specialized high-speed output configuration
-
vs. Woodward 5437 modules: GE offers specialized configuration and optimized for Mark IV integration
Selection Suggestions
-
Critical: Confirm the specialized configuration specifics – the “HLO” variant may have unique timing, sequencing, or fault handling features; standard documentation may not fully apply
-
Critical: Confirm output configuration (sourcing vs. sinking) – jumper settings must match your field devices
-
Critical: Confirm output load current – do not exceed 0.5A per output channel
-
Verify your backplane provides both +5V and +24V field power with sufficient current capacity (+24V @ 0.3A)
-
Assess channel count – 8 outputs are suitable for specialized applications
-
Evaluate environmental conditions – A coating is suitable for clean, dry indoor installations; upgrade to B/C/D/G/H if needed
-
Order mating front connector (p/n may vary – confirm with GE)
-
For critical protection applications, consider used/refurbished units with 90-day warranty
Precautions
-
Critical: The “HLO” designation may indicate specialized configuration – do not assume standard HLN parameters apply; verify all specifications with the manufacturer or supplier
-
Critical: Do not exceed 30V DC or 0.5A per output channel – overvoltage or overcurrent may damage the output transistors
-
Critical: Do not short-circuit output channels – outputs are protected but prolonged shorts may cause damage
-
Critical: High-speed outputs are sensitive to inductive kickback from solenoids – use flyback diodes or surge suppressors across inductive loads to prevent damage
-
Ensure field power supply (+24V DC) is stable and within 10–30V DC range
-
Use properly sized wiring for output currents – undersized wires may cause voltage drop and overheating
-
Basic A coating does not protect against humidity or corrosive gases – upgrade to B/C/D/G/H if your environment has moisture or chemicals
-
Allow 30-minute warm-up before commissioning
-
Store in ESD-safe packaging – edge connector is static-sensitive
-
Periodically verify output operation every 6 months (critical protection circuits require frequent testing)
-
Do not hot-swap – Mark IV backplanes require power-off for insertion/removal
-
If replacing a similar specialized board, verify wiring and pinout compatibility – HLOA may differ from other HLN series in pin assignments

AB 1734-IB8S
ABB 1/24VDC
A-B 1794-IE8