DS3800HIOD GE

¥999.00

The DS3800HIOD is a General Electric Mark IV Speedtronic turbine control board, a hybrid analog input/output module with a suffix indicating a different channel configuration or specialized functionality compared to the HIOA and HIOB series. The “D” suffix typically denotes a variant with enhanced diagnostics, different I/O mixing, or specialized scaling, along with basic conformal coating (or potentially enhanced coating depending on the full suffix – here the “D” at the end indicates coating level). This board is designed for applications requiring a specific balance of analog inputs and outputs with advanced monitoring capabilities.

Category:

Description

Parameters

  • Analog Inputs: 4 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)

  • Analog Outputs: 8 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)

  • Resolution: 12-bit ADC (inputs) / 12-bit DAC (outputs)

  • Accuracy: ±0.1% of full scale

  • Input Impedance: 250Ω (current) / >1MΩ (voltage)

  • Output Drive: 4–20mA into 750Ω max / 0–10V into 5kΩ min

  • Isolation: 1500V RMS optical isolation (channel-to-backplane)

  • Power: +5V DC @ 1.0A, +15V DC @ 0.35A (higher due to more output channels)

  • Scan/Update Rate: 100ms (inputs) / 100ms (outputs)

  • Coating: Basic conformal coating (suffix D – single-layer acrylic, though note D typically indicates improved coating in other series; verify actual coating level with supplier)

  • Temp Range: 0°C to +60°C (or extended if D indicates enhanced coating)

  • Mounting: 6U VME Eurocard, single-slot

  • Diagnostics: Enhanced LED status per channel (input over-range/under-range, output fault/open-circuit, load monitoring)

Advantages & Features

  • Higher output density – 8 analog outputs + 4 analog inputs on a single board, providing more actuation channels than HIOA (4 in/4 out) and HIOB (8 in/4 out)

  • Hybrid I/O capability – combines inputs and outputs on one board, saving cabinet space

  • Versatile signal support – inputs and outputs independently configurable for 4–20mA or 0–10V, compatible with most industrial actuators and transmitters

  • Enhanced output diagnostics – load monitoring and fault detection on each output channel

  • Isolated channels reduce ground loop interference and protect the backplane from field wiring faults

  • D-grade coating (if applicable) provides improved moisture resistance over basic coatings

  • Compatible with Mark IV backplanes and some VIe systems (with adapter)

  • Front-panel LEDs for per-channel status including output load faults

Application Cases

  • Multi-actuator control systems – controlling multiple turbine valves (IGV, fuel, steam, bypass) with fewer input channels

  • Fuel gas pressure and flow control – multiple control valve positioners with limited feedback sensors

  • Steam pressure, flow, and temperature control – multiple valve positioners for throttle, extraction, and reheat lines

  • Lube oil temperature and cooling control – multiple cooling water or bypass valve actuators

  • Retrofit projects replacing separate input and output boards where more outputs than inputs are needed

Competitor Comparison

  • vs. DS3800HIOA (A variant): More outputs (8 vs. 4) with same 4 inputs – HIOD offers greater output density

  • vs. DS3800HIOB (B variant): More outputs (8 vs. 4) but fewer inputs (4 vs. 8) – HIOD is output-heavy, HIOB is input-heavy

  • vs. DS3800HOMB (output-only): HIOD offers inputs in addition to outputs, but fewer total outputs (8 vs. typically 16 on output-only boards)

  • vs. DS3800HIMA (input-only): HIOD offers outputs in addition to inputs, but fewer total inputs (4 vs. 8 differential)

  • vs. DS3800HSCB (high-speed analog): HIOD is standard speed (100ms), HSCB offers faster scanning for dynamic signals

  • vs. ABB TB711 : ABB offers higher resolution (14-bit) and PROFIBUS/Modbus communication, but lacks hybrid I/O on a single board

  • vs. Siemens 7MH410 : Siemens offers HART protocol support on some variants, but GE HIOD offers hybrid I/O in one slot

  • vs. Woodward 8440-2015 : Woodward offers more flexible configuration software, but GE HIOD provides a compact hybrid solution

  • vs. Honeywell 51304638 : Honeywell offers better long-term stability (±0.05%), but GE HIOD combines inputs and outputs with output load monitoring

Selection Suggestions

  • Critical: Confirm input and output signal types (4–20mA or 0–10V) before installation – jumpers must match your transmitters and actuators

  • Verify your backplane provides both +5V and +15V with sufficient current capacity (+5V @ 1.0A, +15V @ 0.35A)

  • Assess channel mix – this board is ideal for applications requiring more actuator outputs than sensor inputs

  • Determine accuracy requirement – 0.1% is sufficient for most turbine control loops

  • Evaluate environmental conditions – verify the actual coating level for the “D” suffix (may be basic or enhanced depending on revision)

  • Order mating front connector (p/n may vary – confirm with GE)

  • For critical applications, consider used/refurbished units with 90-day warranty

Precautions

  • Critical: Do not exceed 30mA or ±30V on input channels – overvoltage may damage the ADC and isolation circuits

  • Critical: Do not short-circuit output channels – outputs are protected but prolonged shorts may cause damage

  • Critical: Monitor output load – outputs are rated for specific loads; exceeding the rating may cause overheating or failure

  • Critical: Use shielded twisted-pair cables for all analog inputs and outputs to avoid EMI – especially near VFDs or large transformers

  • Ensure field power supply (+24V DC) for loop-powered transmitters is stable (if used)

  • Verify the actual coating level for the “D” suffix – in some series D indicates enhanced coating, in others it may be basic; confirm with supplier documentation

  • Allow 30-minute warm-up before calibration

  • Store in ESD-safe packaging – edge connector is static-sensitive

  • Periodically verify input and output calibration every 2 years against a certified reference

  • Do not hot-swap – Mark IV backplanes require power-off for insertion/removal

  • If replacing separate input and output boards, verify wiring and pinout compatibility – HIOD may differ from HIOA/HIOB series in pin assignments

A-B 1794-IE8
A-B 1756-OB16E
A-B 1756-OB32