DS3800HIOB GE

¥999.00

The DS3800HIOB is a General Electric Mark IV Speedtronic turbine control board, a hybrid analog input/output module with higher channel density than the HIOA series. The “B” suffix typically indicates a variant with more analog input/output channels or a different configuration, along with basic conformal coating for standard indoor protection. This board is designed for applications requiring more analog control loops in a single slot.

Category:

Description

Parameters

  • Analog Inputs: 8 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)

  • Analog Outputs: 4 channels, 4–20mA (default) or 0–10V DC (jumper-configurable)

  • Resolution: 12-bit ADC (inputs) / 12-bit DAC (outputs)

  • Accuracy: ±0.1% of full scale

  • Input Impedance: 250Ω (current) / >1MΩ (voltage)

  • Output Drive: 4–20mA into 750Ω max / 0–10V into 5kΩ min

  • Isolation: 1500V RMS optical isolation (channel-to-backplane)

  • Power: +5V DC @ 1.1A, +15V DC @ 0.35A (higher than HIOA due to more channels)

  • Scan/Update Rate: 100ms (inputs) / 100ms (outputs)

  • Coating: Basic conformal coating (suffix B) – single-layer acrylic

  • Temp Range: 0°C to +60°C

  • Mounting: 6U VME Eurocard, single-slot

  • Diagnostics: LED status per channel (input over-range/under-range, output fault/open-circuit)

Advantages & Features

  • Higher channel density – 8 analog inputs + 4 analog outputs on a single board, providing more control loops than HIOA (4 in/4 out)

  • Hybrid I/O capability – combines inputs and outputs on one board, saving cabinet space

  • Versatile signal support – inputs and outputs independently configurable for 4–20mA or 0–10V, compatible with most industrial transmitters and actuators

  • Isolated channels reduce ground loop interference and protect the backplane from field wiring faults

  • Basic B-grade coating provides light moisture and dust protection for indoor installations

  • Compatible with Mark IV backplanes and some VIe systems (with adapter)

  • Front-panel LEDs for per-channel status

Application Cases

  • Turbine inlet guide vane (IGV) position control – reading multiple position feedbacks and outputting to positioners

  • Fuel gas pressure and flow control – multiple pressure transmitters and control valve positioners in gas turbine fuel skids

  • Steam pressure, flow, and temperature control – for steam turbine throttle, extraction, and reheat lines

  • Lube oil pressure, temperature, and cooling control – multiple sensors and actuators on bearing systems

  • Retrofit projects replacing separate input and output boards with a single hybrid solution

Competitor Comparison

  • vs. DS3800HIOA (A variant): More inputs (8 vs. 4) with same 4 outputs – HIOB offers greater channel density at the cost of slightly higher power consumption

  • vs. DS3800HIMA (input-only): HIOB offers outputs in addition to inputs, but fewer total inputs (8 vs. 8 differential on HIMA)

  • vs. DS3800HOMB (output-only): HIOB offers inputs and outputs in a single board, reducing board count

  • vs. DS3800HSCB (high-speed analog): HIOB is standard speed (100ms), HSCB offers faster scanning for dynamic signals

  • vs. ABB TB711 : ABB offers higher resolution (14-bit) and PROFIBUS/Modbus communication, but lacks hybrid I/O on a single board

  • vs. Siemens 7MH410 : Siemens offers HART protocol support on some variants, but GE HIOB offers hybrid I/O in one slot

  • vs. Woodward 8440-2015 : Woodward offers more flexible configuration software, but GE HIOB provides a compact hybrid solution

  • vs. Honeywell 51304638 : Honeywell offers better long-term stability (±0.05%), but GE HIOB combines inputs and outputs

Selection Suggestions

  • Critical: Confirm input and output signal types (4–20mA or 0–10V) before installation – jumpers must match your transmitters and actuators

  • Verify your backplane provides both +5V and +15V with sufficient current capacity (+5V @ 1.1A, +15V @ 0.35A)

  • Assess channel count – 8 inputs and 4 outputs cover medium-sized control loop applications

  • Determine accuracy requirement – 0.1% is sufficient for most turbine control loops

  • Evaluate environmental conditions – B coating is suitable for clean, dry indoor installations; upgrade to C/D/G/H if needed

  • Order mating front connector (p/n may vary – confirm with GE)

  • For critical applications, consider used/refurbished units with 90-day warranty

Precautions

  • Critical: Do not exceed 30mA or ±30V on input channels – overvoltage may damage the ADC and isolation circuits

  • Critical: Do not short-circuit output channels – outputs are protected but prolonged shorts may cause damage

  • Critical: Use shielded twisted-pair cables for all analog inputs and outputs to avoid EMI – especially near VFDs or large transformers

  • Ensure field power supply (+24V DC) for loop-powered transmitters is stable (if used)

  • Basic B coating does not protect against humidity or corrosive gases – upgrade to C/D/G/H if your environment has moisture or chemicals

  • Allow 30-minute warm-up before calibration

  • Store in ESD-safe packaging – edge connector is static-sensitive

  • Periodically verify input and output calibration every 2 years against a certified reference

  • Do not hot-swap – Mark IV backplanes require power-off for insertion/removal

  • If replacing separate input and output boards, verify wiring and pinout compatibility – HIOB may differ from HIOA or other series in pin assignments

A-B 1756-IM16I
ABB NKAS01-15
MITSUBISHI AJ65BT-64DAV