Product Type: High-Current Input Conditioning Board (Revision 1E1E)
-
Part Number: DS3800HCIC1E1E
-
Manufacturer: General Electric (GE)
-
System Compatibility: GE Speedtronic Mark IV Turbine Control Systems (Rev. M and later)
-
Input Channels: 16 high-current digital inputs
-
Input Type: Sourcing or sinking (jumper-selectable per channel)
-
Input Voltage Range: 24Vdc, 48Vdc, or 125Vdc (jumper-selectable)
-
Input Current: Up to 75mA per channel – absolute maximum in series
-
Input Impedance: Selectable 10kΩ, 5kΩ, 2.5kΩ, 1.2kΩ, or 600Ω (jumper-selectable) – widest range
-
Input Threshold: 15V (on) / 5V (off) for 24V mode; 30V/10V for 48V; 80V/25V for 125V
-
Filtering: Programmable 1ms, 5ms, 10ms, 50ms, 100ms, or 200ms debounce filter (jumper-selectable) – widest range
-
Protection: Over-current, reverse-polarity, transient protection (enhanced TVS), and input filtering
-
Diagnostics: Individual channel fault detection (over-current, open-circuit, stuck-on/stuck-off, input voltage monitoring, channel health, impedance variation) with LED indication and backplane reporting
-
Isolation: 2500Vrms reinforced opto-isolation with enhanced common-mode transient immunity (> 120kV/µs) – highest in series
-
Temperature Range: -40°C to +90°C – widest in series
-
MTBF: > 300,000 hours (MIL-HDBK-217F)
Key Features & Advantages
-
Maximum Drive Capability: The GE DS3800HCIC1E1E accepts up to 75mA per input, providing the highest margin for the most demanding long cable runs and high-power field devices.
-
Widest Filtering Range: Programmable debounce filtering from 1ms to 200ms eliminates contact bounce and electrical noise in the most challenging environments.
-
Broadest Impedance Selection: Five impedance options (10kΩ, 5kΩ, 2.5kΩ, 1.2kΩ, 600Ω) allow optimization for extreme noise immunity or current consumption.
-
Most Advanced Diagnostics: Individual channel fault detection (over-current, open-circuit, stuck-on/stuck-off, input voltage monitoring, channel health, impedance variation) with LED and backplane reporting for predictive maintenance.
-
Highest Transient Immunity: > 120kV/µs common-mode transient immunity for superior noise rejection.
-
Widest Temperature Range: -40°C to +90°C suits the most extreme environments.
-
Widest Input Voltage Range: Supports 24Vdc, 48Vdc, or 125Vdc, compatible with various plant power systems.
Typical Application Cases
-
Proximity Switch Interfacing: Interfaces with high-current proximity sensors and limit switches with advanced noise filtering.
-
Relay Contact Monitoring: Monitors field relay contacts with configurable debounce filtering.
-
Ultra-Long-Distance Signaling: Supports input signals from devices located > 1500m away.
-
Motor Starter Feedback: Monitors auxiliary contacts from motor starters and contactors.
-
Extreme Environment Installations: Widest temperature range suits offshore, arctic, or desert sites.
-
High-Noise Environments: Enhanced impedance and filtering options for VFD-heavy installations and arc furnace areas.
Competitive Comparison
| Feature | DS3800HCIC1E1E | DS3800HCIC1D1D | DS3800HCIC (Base) | Modern Digital Input Module |
|---|---|---|---|---|
| Input Current | 75mA | 60mA | 50mA | 2-5mA |
| Impedance Options | 10k/5k/2.5k/1.2k/600Ω | 10k/5k/2.5k/1.2kΩ | 10k/5k/2.5kΩ | Fixed (10kΩ) |
| Filtering Range | 1ms to 200ms | 1ms to 100ms | 1ms to 50ms | Software-configurable |
| Diagnostics | LED+BP+health+impedance | LED+BP+health | LED+BP+voltage | Software diagnostics |
| Transient Immunity | > 120kV/µs | > 100kV/µs | > 75kV/µs | 10kV/µs |
| Temperature Range | -40°C to +90°C | -40°C to +85°C | -40°C to +80°C | 0°C to +60°C |
| Compatibility | Mark IV Rev. M+ | Mark IV Rev. M+ | Mark IV Rev. M+ | Universal |
The GE DS3800HCIC1E1E is the absolute pinnacle of the HCIC series, offering the highest current, widest filtering and impedance range, most advanced diagnostics, and broadest environmental tolerance.
Selection Guidelines & Precautions
-
Input Voltage Selection: Verify field device voltage. Configure jumpers for 24V, 48V, or 125Vdc.
-
Sourcing/Sinking Selection: Set per channel to match your field device wiring.
-
Impedance Selection: Select 10kΩ for standard, 5kΩ for moderate noise, 2.5kΩ for high noise, 1.2kΩ for extreme noise, or 600Ω for maximum noise immunity (higher current consumption).
-
Filter Selection: Set debounce filter: 1ms for fast signals, 50ms for standard contacts, 100ms for noisy contacts, or 200ms for very slow or extremely noisy contacts.
-
Cable Length: Supports cables up to 1500m. For longer runs, verify voltage drop.
-
Diagnostic Reporting: Requires Mark IV firmware Rev. M or later for full diagnostic support.
-
Channel Health & Impedance Monitoring: Familiarize yourself with fault codes for channel health and impedance variation diagnostics.
-
Wiring: Use shielded twisted-pair cables; ground shield at board end only.
-
Commissioning: Verify input voltage and current with a multimeter. Test each channel with a simulated input.
-
ESD Handling: Use ESD-safe practices.
-
Sourcing: Obsolete. Request functional test report including:
-
All 16 channels tested at 24V, 48V, and 125V
-
Threshold verification
-
Filter verification at all settings (1ms to 200ms)
-
Impedance verification (10k/5k/2.5k/1.2k/600Ω)
-
Diagnostic reporting validation (including channel health and impedance variation)
-
Transient immunity test (> 120kV/µs)
-
Isolation test (2500Vrms)
-
-
Spare Strategy: Keep one spare GE DS3800HCIC1E1E on-site for critical input monitoring applications. This is the ultimate choice for the most demanding harsh and high-noise environments. If unavailable, the DS3800HCIC1D1D is a compatible alternative with reduced specifications. Proactive replacement after 10 years of continuous operation is recommended.

A-B 1762-IF4
A-B 1756-OB16I
A-B 1746-P3
A-B 1756-IB32