Description
Technical Specifications
-
Product Type: High-Amplitude Current Analog Output Board
-
Part Number: DS3800HACA
-
Manufacturer: General Electric (GE)
-
System Compatibility: GE Speedtronic Mark IV Turbine Control Systems
-
Output Channels: 4 independent analog current outputs
-
Output Type: 4-20mA or 0-20mA (jumper-selectable), loop-powered
-
Drive Capability: Up to 50mA per channel (sourcing or sinking)
-
Loop Power: Internal 24Vdc loop power supply (isolated)
-
Compliance Voltage: 24Vdc (allows driving loads up to 600Ω at 20mA)
-
Resolution: 12-bit
-
Accuracy: ±0.1% of full scale at 25°C; ±0.02% per °C drift
-
Protection: Over-current, short-circuit, and reverse-polarity protection per channel
-
Isolation: 2500Vrms reinforced isolation (logic-to-output)
-
Temperature Range: -40°C to +70°C (extended)
-
MTBF: > 150,000 hours (MIL-HDBK-217F)
Key Features & Advantages
-
High Drive Capability: The GE DS3800HACA delivers up to 50mA per channel, suitable for driving multiple field devices in parallel or long cable runs.
-
Loop-Powered Outputs: Integrated 24Vdc loop power eliminates the need for external power supplies for 4-20mA loops.
-
High Compliance Voltage: 24V compliance allows driving loads up to 600Ω, accommodating most industrial field devices.
-
Sourcing or Sinking: Jumper-selectable sourcing or sinking modes for flexibility with different device configurations.
-
Reinforced Isolation: 2500Vrms for ground loop protection and safety in industrial environments.
-
Comprehensive Protection: Over-current, short-circuit, and reverse-polarity protection safeguards the board and field devices.
-
Diagnostic LEDs: Front-panel LEDs indicate output status, fault, and loop power presence per channel.
Typical Application Cases
-
I/P (Current-to-Pressure) Converters: The GE DS3800HACA drives I/P converters that control pneumatic valve actuators in process applications.
-
Valve Positioners: Provides 4-20mA control signals for smart and analog valve positioners.
-
Long-Distance Transmitter Powering: Supplies loop power and control signal to remote transmitters over distances up to 1000m.
-
Variable Speed Drives (VSDs): Provides 4-20mA speed reference signals to VSDs controlling pumps and fans.
-
Damper and Louver Actuators: Controls 4-20mA actuated dampers for airflow regulation.
Competitive Comparison
| Feature | GE DS3800HACA | GE DS3800HA1C (Voltage) | GE DS3800DSAB (Servo) | Modern Analog Output Module |
|---|---|---|---|---|
| Output Type | Current (4-20mA) | Voltage or current | Current (±mA) | Voltage or current |
| Max Current | 50mA | 2A (voltage mode) | ±80mA | 20-25mA |
| Loop Power | Internal (24V) | N/A | N/A | External required |
| Compliance Voltage | 24V (600Ω load) | N/A | N/A | 12-15V typical |
| Protection | Over-current + reverse | Over-current + thermal | Over-current | Short-circuit only |
| Isolation | 2500Vrms | 1500Vrms | 1500Vrms | 500Vrms |
| Temperature Range | -40°C to +70°C | 0°C to +60°C | 0°C to +60°C | 0°C to +60°C |
| Compatibility | Mark IV | Mark IV | Mark IV | Universal fieldbus |
The GE DS3800HACA is the only Mark IV board specifically designed for high-current loop-powered 4-20mA applications, with integrated loop power and high compliance voltage.
Selection Guidelines & Precautions
-
Loop Configuration: Verify whether your field devices require sourcing or sinking configuration. Set jumpers on GE DS3800HACA accordingly. Incorrect mode will result in no output signal.
-
Load Resistance Calculation: The GE DS3800HACA can drive up to 600Ω at 20mA. Calculate total loop resistance (device + cable). If exceeding 600Ω, the output will saturate.
-
Loop Power: The internal 24V loop power is isolated. Ensure the field device does not have its own power supply to avoid conflicts.
-
Cable Length: The GE DS3800HACA can drive cables up to 1000m. For longer runs, consider reducing load or using a repeater.
-
Short-Circuit Protection: While protected, repeated shorting may affect long-term reliability. Check wiring before power-up.
-
Reverse Polarity: The GE DS3800HACA is reverse-polarity protected; however, verify wiring to avoid unnecessary fault indications.
-
Commissioning: Use a precision current meter to verify each channel’s output during startup. Calibrate if necessary using onboard trimmers.
-
Wiring: Use shielded twisted-pair cables; ground shield at board end only.
-
ESD Handling: Use ESD-safe practices.
-
Sourcing: Obsolete. Request functional test report including:
-
All 4 channels tested at 4mA and 20mA
-
Load regulation test (up to 600Ω)
-
Loop power verification (24V)
-
Sourcing/sinking mode verification
-
Over-current and reverse-polarity protection validation
-
Isolation test (2500Vrms)
-
-
Spare Strategy: Keep one spare GE DS3800HACA on-site if you rely on 4-20mA control for critical actuators or positioners.

Panasonic MSM5AZP1A
A-B 1746-P3
FOXBORO P0916CC


Reviews