DS3800DVIA GE

¥999.00

The GE DS3800DVIA is a Digital Voltage Input Analog board for the GE Speedtronic Mark IV turbine control system. It provides high-density analog input conditioning for voltage-based field signals, converting them into standardized signals for the Mark IV processor. The “DVIA” designation indicates a board dedicated to voltage inputs, distinguishing it from current-input or mixed-signal boards.

Category:

Description

Technical Specifications

  • Product Type: Digital Voltage Input Analog Board

  • Part Number: DS3800DVIA

  • Manufacturer: General Electric (GE)

  • System Compatibility: GE Speedtronic Mark IV Turbine Control Systems

  • Input Channels: 16 differential analog voltage inputs

  • Input Range: ±10Vdc, 0-10Vdc, 0-5Vdc (jumper-selectable per channel)

  • Input Impedance: > 10MΩ (differential)

  • Resolution: 12-bit (approx. 4.88mV per LSB at ±10V range)

  • Accuracy: ±0.1% of full scale at 25°C; ±0.02% per °C drift

  • Filtering: Fixed 10Hz low-pass filter (hardware)

  • Protection: Over-voltage protection (±30V continuous); ESD protection

  • Isolation: 1500Vrms opto-isolation between field inputs and logic

  • Temperature Range: 0°C to +60°C

  • MTBF: > 200,000 hours (MIL-HDBK-217F)


Key Features & Advantages

  • High Channel Density: The GE DS3800DVIA provides 16 voltage inputs on a single 6U board, maximizing rack space efficiency.

  • Field-Selectable Ranges: Each channel is individually configurable for ±10V, 0-10V, or 0-5V via jumpers, accommodating a wide range of field sensors.

  • Precision Conditioning: The GE DS3800DVIA uses precision resistor networks (0.01%) and low-drift op-amps to ensure accurate, stable readings.

  • Fixed Filtering: The integrated 10Hz low-pass filter removes high-frequency noise, providing stable readings in electrically noisy turbine environments.

  • Diagnostic LEDs: Front-panel LEDs indicate over-range, open-circuit, and fault conditions per channel.

  • Input Protection: ±30V continuous over-voltage protection prevents damage from wiring errors or transients.


Typical Application Cases

  • Thermocouple Amplifier Outputs: The GE DS3800DVIA reads conditioned thermocouple signals (0-10V) from external amplifiers in older installations.

  • Pressure Transducer Monitoring: Reads 0-10V or 0-5V signals from pressure transmitters on lube oil, fuel gas, and hydraulic systems.

  • Position Feedback: Reads ±10V signals from linear potentiometers or position transducers on actuators and valves.

  • Speed Pickup Signals: Reads voltage signals from magnetic speed pickups (0-10V) for turbine speed monitoring.

  • Temperature Transmitter Outputs: Reads 0-10V outputs from temperature transmitters for bearing and exhaust monitoring.


Competitive Comparison

Feature GE DS3800DVIA GE DS3800DICA (Current Input) Modern PLC Analog Module
Input Type Voltage (±10V, 0-10V, 0-5V) Current (4-20mA) Voltage or current
Channels 16 16 8-16
Resolution 12-bit 12-bit 16-bit
Filtering Fixed 10Hz Fixed 10Hz Software-configurable
Isolation 1500Vrms 1500Vrms 500Vrms
Diagnostics LED per channel LED per channel Software diagnostics
Compatibility Mark IV backplane Mark IV backplane Universal fieldbus

The GE DS3800DVIA is the voltage-input counterpart to the current-input DS3800DICA. Modern PLC analog modules offer higher resolution and digital diagnostics but require protocol conversion for Mark IV systems.


Selection Guidelines & Precautions

  1. Range Selection: Configure jumpers per channel to match your sensor output (±10V, 0-10V, or 0-5V). Incorrect range selection causes clipping or reduced resolution.

  2. Input Impedance: The GE DS3800DVIA has high input impedance (>10MΩ), so it does not load the source. However, verify the source can drive the input (almost always the case).

  3. Filtering Limitation: The fixed 10Hz filter removes 50/60Hz noise but may attenuate fast-changing signals (e.g., dynamic pressure). For high-speed signals, consider a different board or external filter bypass.

  4. Wiring: Use shielded twisted-pair cables for all inputs. Ground shield at the GE DS3800DVIA end only to prevent ground loops.

  5. Over-Voltage Protection: While the GE DS3800DVIA withstands ±30V, prolonged over-voltage may degrade accuracy. Verify wiring before power-up.

  6. Commissioning: Use a precision voltage source to verify each channel’s reading. Adjust calibration if necessary (using onboard trimmers if available).

  7. ESD Handling: Use ESD-safe practices; contains sensitive analog front-end components.

  8. Sourcing: Obsolete. Request functional test report including:

    • All 16 channels tested for accuracy (±0.1%)

    • Range selection verification (±10V, 0-10V, 0-5V)

    • Filter functionality test

    • Over-voltage protection validation

    • Isolation test

  9. Spare Strategy: Keep one spare GE DS3800DVIA on-site. For critical measurements (e.g., overspeed, bearing temperature), consider redundant analog inputs using two boards.


Let me know if you have another model to analyze.