Description
Technical Specifications
-
Product Type: Digital Voltage Input Analog Board
-
Part Number: DS3800DVIA
-
Manufacturer: General Electric (GE)
-
System Compatibility: GE Speedtronic Mark IV Turbine Control Systems
-
Input Channels: 16 differential analog voltage inputs
-
Input Range: ±10Vdc, 0-10Vdc, 0-5Vdc (jumper-selectable per channel)
-
Input Impedance: > 10MΩ (differential)
-
Resolution: 12-bit (approx. 4.88mV per LSB at ±10V range)
-
Accuracy: ±0.1% of full scale at 25°C; ±0.02% per °C drift
-
Filtering: Fixed 10Hz low-pass filter (hardware)
-
Protection: Over-voltage protection (±30V continuous); ESD protection
-
Isolation: 1500Vrms opto-isolation between field inputs and logic
-
Temperature Range: 0°C to +60°C
-
MTBF: > 200,000 hours (MIL-HDBK-217F)
Key Features & Advantages
-
High Channel Density: The GE DS3800DVIA provides 16 voltage inputs on a single 6U board, maximizing rack space efficiency.
-
Field-Selectable Ranges: Each channel is individually configurable for ±10V, 0-10V, or 0-5V via jumpers, accommodating a wide range of field sensors.
-
Precision Conditioning: The GE DS3800DVIA uses precision resistor networks (0.01%) and low-drift op-amps to ensure accurate, stable readings.
-
Fixed Filtering: The integrated 10Hz low-pass filter removes high-frequency noise, providing stable readings in electrically noisy turbine environments.
-
Diagnostic LEDs: Front-panel LEDs indicate over-range, open-circuit, and fault conditions per channel.
-
Input Protection: ±30V continuous over-voltage protection prevents damage from wiring errors or transients.
Typical Application Cases
-
Thermocouple Amplifier Outputs: The GE DS3800DVIA reads conditioned thermocouple signals (0-10V) from external amplifiers in older installations.
-
Pressure Transducer Monitoring: Reads 0-10V or 0-5V signals from pressure transmitters on lube oil, fuel gas, and hydraulic systems.
-
Position Feedback: Reads ±10V signals from linear potentiometers or position transducers on actuators and valves.
-
Speed Pickup Signals: Reads voltage signals from magnetic speed pickups (0-10V) for turbine speed monitoring.
-
Temperature Transmitter Outputs: Reads 0-10V outputs from temperature transmitters for bearing and exhaust monitoring.
Competitive Comparison
| Feature | GE DS3800DVIA | GE DS3800DICA (Current Input) | Modern PLC Analog Module |
|---|---|---|---|
| Input Type | Voltage (±10V, 0-10V, 0-5V) | Current (4-20mA) | Voltage or current |
| Channels | 16 | 16 | 8-16 |
| Resolution | 12-bit | 12-bit | 16-bit |
| Filtering | Fixed 10Hz | Fixed 10Hz | Software-configurable |
| Isolation | 1500Vrms | 1500Vrms | 500Vrms |
| Diagnostics | LED per channel | LED per channel | Software diagnostics |
| Compatibility | Mark IV backplane | Mark IV backplane | Universal fieldbus |
The GE DS3800DVIA is the voltage-input counterpart to the current-input DS3800DICA. Modern PLC analog modules offer higher resolution and digital diagnostics but require protocol conversion for Mark IV systems.
Selection Guidelines & Precautions
-
Range Selection: Configure jumpers per channel to match your sensor output (±10V, 0-10V, or 0-5V). Incorrect range selection causes clipping or reduced resolution.
-
Input Impedance: The GE DS3800DVIA has high input impedance (>10MΩ), so it does not load the source. However, verify the source can drive the input (almost always the case).
-
Filtering Limitation: The fixed 10Hz filter removes 50/60Hz noise but may attenuate fast-changing signals (e.g., dynamic pressure). For high-speed signals, consider a different board or external filter bypass.
-
Wiring: Use shielded twisted-pair cables for all inputs. Ground shield at the GE DS3800DVIA end only to prevent ground loops.
-
Over-Voltage Protection: While the GE DS3800DVIA withstands ±30V, prolonged over-voltage may degrade accuracy. Verify wiring before power-up.
-
Commissioning: Use a precision voltage source to verify each channel’s reading. Adjust calibration if necessary (using onboard trimmers if available).
-
ESD Handling: Use ESD-safe practices; contains sensitive analog front-end components.
-
Sourcing: Obsolete. Request functional test report including:
-
All 16 channels tested for accuracy (±0.1%)
-
Range selection verification (±10V, 0-10V, 0-5V)
-
Filter functionality test
-
Over-voltage protection validation
-
Isolation test
-
-
Spare Strategy: Keep one spare GE DS3800DVIA on-site. For critical measurements (e.g., overspeed, bearing temperature), consider redundant analog inputs using two boards.