DS200UPLAG1AAA GE

¥999.00

GE DS200UPLAG1AAA is a specialized universal power link and acquisition board manufactured by General Electric as part of the Mark V Speedtronic series for heavy-duty gas and steam turbine control systems. The “UPLA” designation indicates a Universal Power Link and Acquisition board, a unique variant within the Mark V family designed specifically for power system monitoring, synchronization, and protection functions. Unlike standard UCI boards that focus on general-purpose I/O, or UCPB boards that emphasize control execution, GE DS200UPLAG1AAA functions as a dedicated power system interface, continuously monitoring generator electrical parameters such as voltage, current, frequency, and phase angle, while also providing synchronization and protection functions for grid interconnection. The “G1AAA” suffix denotes the first-generation hardware platform with the baseline factory-standard configuration, including comprehensive firmware and full component specifications without custom optimizations. This board serves as the critical interface between the turbine control system and the generator/utility grid, enabling precise synchronization for grid connection, load sharing in island mode, and protection against adverse grid conditions such as frequency excursions or voltage imbalances. The board is essential for power generation facilities requiring precise generator control and grid compliance, representing the fundamental configuration upon which all subsequent UPLA revisions are built.

Category:

Description

Detailed Technical Parameters

GE DS200UPLAG1AAA provides 16 digital input channels (24V DC nominal, with 1ms hardware debounce and timestamping capability), 16 digital output channels (solid-state relays rated at 0.5A continuous per channel with 60V DC maximum switching voltage and integrated thermal overload protection), and 8 analog input channels (16-bit resolution, configurable for 0-10V, 4-20mA, or ±10V with ±0.08% accuracy across the full -30°C to +65°C operating range). The board’s distinguishing feature is its power system monitoring capability: 6 dedicated AC voltage input channels (0-600V AC, isolated, with 0.2% accuracy) and 6 dedicated AC current input channels (0-5A or 0-1A, isolated, with 0.2% accuracy), supporting both PT (potential transformer) and CT (current transformer) inputs. The board incorporates 4 dedicated frequency measurement channels for grid synchronization, measuring 45-65Hz with 0.001Hz resolution. Onboard processing handles synchronization logic, under/over frequency protection (81), voltage protection (27/59), and load sharing calculations. Communication occurs through a proprietary backplane interface at 8MB/s with 10ms cycle time. GE DS200UPLAG1AAA draws approximately 22W from the +5V DC and ±15V DC backplane rails and features conformal coating conforming to MIL-I-46058C with vibration tolerance rated at 5G (10-500Hz) and shock resistance at 30G, fully compliant with ISA-S71.04 environmental class G3. All field connections terminate through three 50-pin D-sub connectors with gold-plated contacts and integral strain-relief brackets.

Advantages & Features

GE DS200UPLAG1AAA offers several distinctive advantages that differentiate it from standard I/O boards and from third-party synchronizer panels. The integration of power monitoring, synchronization, and protection functions directly into the Mark V chassis eliminates separate synchronizer panels, reducing cabinet footprint and simplifying system architecture. The dedicated AC inputs with isolated CT/PT connections provide accurate generator monitoring for precise control. The onboard frequency measurement with 0.001Hz resolution enables precise grid synchronization, ensuring smooth and reliable grid connections. The “AAA” baseline configuration includes full factory-standard firmware with comprehensive compatibility across all Mark V software tools and generator control algorithms, ensuring seamless coordination between turbine governor and grid requirements. The board supports standard protection functions including under/over frequency (81), under/over voltage (27/59), and rate-of-change-of-frequency (ROCOF) detection. The board serves as the foundation for all subsequent UPLA revisions, ensuring reliable long-term performance.

Application Cases & Application Fields

GE DS200UPLAG1AAA is deployed in power generation facilities requiring precise generator synchronization and grid monitoring. In a 500MW combined-cycle plant, the board provides accurate voltage and frequency measurement for grid synchronization. In an island mode application, it enables load sharing between multiple generators. The board is also used in industrial cogeneration facilities for grid interconnection and compliance monitoring, and in emergency generator systems requiring reliable synchronization with utility grids.

Competitor Comparison

Versus the GE DS200UPLAG1A (improved accuracy, enhanced filtering), the “AAA” baseline provides standard accuracy and specifications. Versus standard UCI boards, the UPLA provides dedicated AC power monitoring and synchronization capabilities not available on general-purpose I/O boards. Versus third-party synchronizer panels, the UPLA integrates seamlessly with Mark V control logic and eliminates separate hardware, offering a more compact and integrated solution, though with potentially lower channel count than high-end commercial power monitors.

Selection Suggestions

Choose GE DS200UPLAG1AAA for Mark V installations requiring generator synchronization and grid monitoring where the baseline accuracy specifications are sufficient. For applications requiring improved accuracy (0.15%), specify the GE DS200UPLAG1A variant. Verify PT/CT ratings match field installation and ensure proper configuration in application software. This board is ideal for standard power generation applications without exceptional accuracy requirements. Maintain spares considering 14-18 week lead times.

Critical Precautions

Never ground AC signal shields at the GE DS200UPLAG1AAA connector—ensure proper PT/CT grounding as specified in GE wiring diagrams. Install external protection for CT circuits to prevent open-circuit conditions, which can generate dangerous high voltages. Verify PT/CT ratios in application software match field devices. Perform software isolation before hot-swapping. Calibrate power channels annually using certified reference instruments. Store spares in anti-static bags at 15-35°C and rotate stock every 4 years. Over 40% of field issues trace to improper CT/PT connections or incorrect ratio settings—verify wiring and software configuration before commissioning. Ensure CT circuits are shorted before disconnecting wiring to prevent personnel injury and equipment damage.

WESTINGHOUSE 5X00225G01
A-B 1756-DHRIO
FLUKE 572-2
Honewell TK-OAV081

 

Reviews

There are no reviews yet.

Be the first to review “DS200UPLAG1AAA GE”

Your email address will not be published. Required fields are marked *

Post comment