Description
Technical Parameters
Manufacturer: GE
Series: Mark V / Mark VIe
Channels: 16 differential
Input Range: -10 mV to +100 mV (Type J/K/T/E)
Cold Junction: Single onboard sensor with enhanced linearization and thermal isolation
Isolation: 1500V AC
Accuracy: ±0.08% at 25°C, ±0.15% across full temperature range
Sampling: 10 Hz sequential
Temp Range: -30°C to +70°C (operating)
Storage: -40°C to +85°C
Mounting: VME rack
Suffix “G2B”: Enhanced accuracy (0.08%) + G2 wiring configuration (different channel-to-terminal mapping than G1) + extended diagnostics (drift, degradation, sense-lead) + extended upper temperature (70°C) + basic diagnostics + fixed firmware
Key Features
-
Enhanced accuracy – ±0.08% for critical temperature monitoring
-
Extended diagnostics – drift monitoring, degradation prediction, and sense-lead integrity checks
-
Faster sampling – 10 Hz for responsive monitoring
-
G2-specific wiring configuration – unique channel-to-terminal mapping matching specific GE cabinet wiring standards; direct drop-in for G2-configured systems
-
Extended upper temperature limit – operates up to 70°C for hotter cabinets
-
Improved cold-junction compensation – stable readings across ambient variations
-
Simple swap – no firmware changes required in most Mark V systems
-
LED status per channel + board health, with extended diagnostic indicators
-
Standard conformal coating for moisture/dust resistance
-
Backward compatible with Mark V and Mark VIe (hot-swap only on VIe Rev D+)
Applications
-
Legacy gas turbine retrofits with G2 wiring – where existing field wiring uses G2 terminal assignments and higher accuracy with diagnostics is required
-
Steam turbine bearing monitoring in G2 cabinets – critical protection with drift anticipation
-
Pipeline compressor stations with G2-configured cabinets – precision monitoring with predictive maintenance
-
Industrial cogeneration plants – where OEM specified G2 wiring for thermocouple terminations
-
Facilities with G2-standard cabinets requiring diagnostic insights
Comparison with Competitors
| Feature | DS200TCPDG2B |
ABB TTH300 | Siemens 7KG7750 |
|---|---|---|---|
| Channels | 16 | 8 | 12 |
| Accuracy | ±0.08% | ±0.10% | ±0.12% |
| Sampling | 10 Hz | 10 Hz (simultaneous) | 8 Hz (simultaneous) |
| Diagnostics | Drift + degradation + open/short | Group-level | Per-channel + HART |
| Temp Range | -30°C to +70°C | -25°C to +65°C | -20°C to +60°C |
| Wiring Config | G2-specific | Standard | Standard |
| GE Native Integration with G2 Cabs | Yes (direct fit) | No | No |
| Hot-Swap | No (V) / Yes (VIe) | No | Yes |
Selection Tips
-
Choose the
DS200TCPDG2Bonly if your cabinet uses G2 wiring configuration and you require enhanced accuracy (±0.08%) with extended diagnostics – this board combines precision, diagnostics, and G2 pinout compatibility -
For G2 systems where ±0.12% accuracy is acceptable without diagnostics, the
DS200TCDAG2Bis more economical -
For G2 systems with high accuracy but no diagnostics, consider
DS200TCEAG2B -
For G1 systems requiring the same features, use the
DS200TCPDG1B -
If you are rewiring the cabinet, consider converting to G1 and using the
DS200TCPDG1BorDS200TCDAG1ADA -
Verify existing wiring pinout against G2 standard – using the wrong terminal block or miswiring will scramble channel readings
-
Source refurbished units with G2 pinout verification and diagnostic test validation in the test report
Precautions
-
ESD sensitive – use wrist strap
-
Power down for Mark V removal (no hot-swap)
-
Torque terminals to 0.5 N·m max
-
Do not exceed -30°C to +70°C operating range – exceeding 70°C reduces component life
-
Pinout critical – G2 mapping differs from G1; verify cabinet wiring before installation
-
Calibrate every 24 months – extended diagnostics depend on a valid baseline calibration
-
Ground shields only at the board end
-
Verify thermocouple type – optimized for J/K (T/E reduces accuracy to ±0.15%)
-
Monitor diagnostic logs – drift warnings indicate sensor aging; plan proactive replacement
-
Label clearly – mark board and slot as “G2B – PRECISION/DIAG” to ensure proper handling and prevent future miswiring with G1 boards
-
Do not mix G1 and G2 boards without verifying terminal block compatibility in the same rack

GE IC695ALG600
GE IC695ALG600-AB
A-B 2097-V32PR2-LM
SANYO STNM-DR-250B(U)


Reviews
There are no reviews yet.