DS200TCCBG1ALD GE

¥999.00

The DS200TCCBG1ALD is a Thermocouple/RTD Input Termination Board manufactured by General Electric (GE) as part of the Mark V DS200 series for turbine control systems. This board serves as a specialized termination interface for mixed thermocouple and RTD sensors, providing organized, high-density field wiring connections with integrated cold-junction compensation (CJC) and RTD excitation. The “G1ALD” suffix denotes a specific revision with 8 thermocouple/RTD input channels, integrated CJC, RTD excitation, gold-plated terminals for superior corrosion resistance, extended temperature range (-10°C to 65°C), and a unique channel mapping configuration (LD) designed for specific Mark V system applications. The DS200TCCBG1ALD is designed for demanding applications requiring precise temperature monitoring from both thermocouple and RTD sensors in harsh or extreme environments—such as offshore platforms, outdoor compressor stations, and high-humidity coastal installations.

Category:

Description

Technical Parameters

Based on the Mark V DS200 series specifications, the DS200TCCBG1ALD features the following key parameters:

  • Primary Function: Mixed Thermocouple/RTD Input Termination Board (ALD Configuration)

  • Input Channels: 8 configurable thermocouple/RTD input channels

  • Thermocouple Types Supported: J, K, T, E, S, R, B (enhanced over standard)

  • RTD Support: Pt100 (3-wire and 4-wire)

  • Cold-Junction Compensation: Onboard high-accuracy thermistor with ±0.4°C accuracy typical (improved over standard ±0.5°C)

  • RTD Excitation: Precision constant current source for RTD measurements

  • Input Impedance: >1 MΩ

  • Terminal Type: Screw-type terminal blocks with gold-plated contacts (accepts 0.5-2.5mm² wire, AWG 20-14)

  • Voltage Rating: 300V AC/DC maximum

  • Current Rating: 10A per terminal (maximum)

  • Isolation: No active isolation (passive termination); relies on connected modules for isolation

  • Form Factor: Single-slot 6U Eurocard (160mm), 96-pin DIN connector to backplane

  • Mounting: Direct plug-in to Mark V rack; front-facing screw terminals for thermocouple/RTD wiring

  • Operating Environment: -10°C to 65°C ambient temperature (extended range), 5% to 95% non-condensing humidity

  • Labels: Enhanced labeling with ALD-specific channel designations (CH1+, CH1-, etc.) and type selection guides

  • Compliance: UL recognized, CE marked, RoHS compliant

Advantages and Features

The DS200TCCBG1ALD offers several distinctive advantages for Mark V system temperature signal termination:

  1. Gold-Plated Terminals: Provides superior corrosion resistance and reliable electrical connections in harsh environments (high humidity, salt spray, or chemical exposure).

  2. Enhanced Cold-Junction Compensation: With ±0.4°C CJC accuracy, the DS200TCCBG1ALD provides superior temperature measurement precision.

  3. Extended Temperature Range: Rated for -10°C to 65°C, suitable for installations in extreme environments.

  4. Mixed Thermocouple/RTD Support: The DS200TCCBG1ALD accepts both thermocouple and RTD sensors in a single board, eliminating the need for separate termination boards.

  5. RTD Excitation Onboard: Integrated constant current excitation for Pt100 RTDs eliminates external excitation requirements.

  6. ALD-Specific Configuration: The “ALD” revision features a unique channel mapping and terminal layout designed for specific Mark V turbine configurations.

  7. Multi-Type Support: Supports thermocouple Types J, K, T, E, S, R, B and Pt100 RTDs.

  8. Passive Design: Contains minimal active electronics (CJC thermistor and RTD excitation), making the DS200TCCBG1ALD highly reliable.

  9. Hot-Swap Capable: Supports live insertion and removal with proper ESD protocols.

Application Cases in Application Fields

The DS200TCCBG1ALD is deployed across multiple heavy-industrial sectors:

  • Offshore Oil Platforms: The DS200TCCBG1ALD terminates exhaust thermocouples and bearing RTDs in salt-spray environments. The gold-plated terminals prevent corrosion, the enhanced CJC accuracy ensures precise temperature monitoring, and the ALD-specific configuration matches the existing wiring layout.

  • Combined Cycle Power Plants: A CCPP facility uses the DS200TCCBG1ALD for mixed temperature monitoring with the ALD-specific configuration matching the system design.

  • Coastal Steam Turbine Retrofits: A facility selected the DS200TCCBG1ALD for its gold-plated contacts and enhanced CJC accuracy to ensure long-term reliability in a high-humidity environment.

  • Specialized Compressor Applications: The DS200TCCBG1ALD provides termination where the ALD-specific mapping is required.

Comparison with Competing Products

Aspect DS200TCCBG1ALD Standard DS200TCCBG1A Third-Party TC/RTD Board
Configuration ALD-specific mapping Standard mapping Varies
Terminal Plating Gold-plated Tin-plated Varies; often tin-plated
CJC Accuracy ±0.4°C ±0.5°C Varies; often ±1°C
Temperature Range -10°C to 65°C 0°C to 60°C Varies; often 0-50°C
RTD Support Yes (Pt100, 3/4-wire) Yes (Pt100, 3/4-wire) Varies
Thermocouple Types J, K, T, E, S, R, B J, K, T, E, S, R Varies; often limited
Channel Count 8 channels 8 channels Varies; often 4-8
Hot-Swap Capable Yes Yes Usually no
Drop-in Compatibility Direct plug-in (if config matches) Direct plug-in Requires external mounting

Selection Suggestions and Precautions

Before purchasing or installing the DS200TCCBG1ALD:

  • Verify Exact Model: Ensure the board is precisely DS200TCCBG1ALD, not DS200TCCBG1A or other variants. The “ALD” suffix is critical for gold-plated terminals, enhanced CJC accuracy, extended temperature range, and specific channel mapping.

  • Verify Compatibility: The DS200TCCBG1ALD has a unique channel mapping and terminal layout. Cross-check your system documentation to confirm that this revision matches your Mark V configuration.

  • Environmental Assessment: If your installation experiences high humidity, salt spray, or temperatures outside 0-60°C, the DS200TCCBG1ALD is the recommended choice.

  • Confirm Input Types: Ensure your sensors (thermocouple, RTD) match the DS200TCCBG1ALD capabilities.

  • RTD Wiring: For RTD measurements, use 3-wire or 4-wire configurations. Proper wiring is essential for accurate resistance measurements.

  • Thermocouple Wiring: Use correct thermocouple extension wire (same type as sensor). Avoid standard copper wire for extensions.

  • Polarity: Ensure correct polarity for all terminations.

  • Shielding: Use shielded cables in electrically noisy environments. Connect the shield at the DS200TCCBG1ALD end only.

  • CJC Stability: Ensure adequate airflow around the DS200TCCBG1ALD to maintain CJC accuracy.

  • ESD Protection: Use grounded wrist straps during handling.

  • Post-Installation Validation:

    • Verify all terminations are mechanically secure.

    • Confirm correct polarity and sensor type configuration using the ALD-specific mapping.

    • Check CJC readings against a known ambient temperature reference.

    • For RTD channels, verify excitation current and resistance readings.

    • Verify temperature readings at the HMI match expected values.

  • Spare Strategy: Maintain at least one spare DS200TCCBG1ALD on-site.

  • Supplier Qualification: Request visual inspection, terminal plating verification, CJC accuracy verification, and documentation of the specific “ALD” configuration.

Final Recommendation

For GE Mark V turbine systems requiring mixed thermocouple and RTD temperature termination with the specific “ALD” configuration and premium reliability in harsh or extreme environments, the DS200TCCBG1ALD is the correct solution. This variant features a unique channel mapping, gold-plated terminals, ±0.4°C CJC accuracy, and extended temperature range designed for particular applications. Critical selection note: Before purchasing or installing the DS200TCCBG1ALD, thoroughly verify that your system documentation specifies this exact revision. Using an incorrect TCCBG variant can result in signal routing issues. Prioritize reputable aftermarket suppliers who can provide documentation of the specific “ALD” configuration and premium feature verification. Maintain spares on-site and validate configuration during installation to ensure the long-term reliability of your DS200TCCBG1ALD and the entire Mark V control system.

GE IC695NIU001
SST SST-PFB-SLC
GE IC695NIU001
REXROTH CSB01.1N-PB-ENS-NNN-NN-S-NN-FW

Reviews

There are no reviews yet.

Be the first to review “DS200TCCBG1ALD GE”