Key Technical Parameters
| Parameter | Specification |
|---|---|
| +5V Output | 7A continuous, 8.5A peak |
| Other Outputs | +15V @2A, -15V @1.5A, +24V @1.2A |
| Input | 115 VAC ±10% (47-63 Hz) ONLY – no DC input option |
| Efficiency | 80% typical at full load |
| Protection | OVP (latch), OCP, OTP (latch – manual reset), 2.5kV surge |
| Diagnostics | 4 LEDs – green “PWR OK”, green “AC OK”, red “FAULT”, yellow “CUR LIM” |
| Conformal Coating | None – standard industrial grade |
| Temp Range | 0 to +50°C ambient (85 CFM forced air recommended) |
| Form Factor | 6U VME, 1-slot width (no adjacent slot clearance required) |
| Weight | 1.35 kg (approx. 3.0 lbs) |
Advantages & Core Features
-
7A capacity – robust mid-range power – The DS200PCCAG7A provides adequate power for Mark V configurations with 16-24 analog inputs, 16-24 digital I/O, 2-3 communication boards, and dual processor modules – scenarios where the 5A models are insufficient but the 9A or 10A models are oversized.
-
Improved efficiency over 5A models – At 80% efficiency (vs. 78% on 5A models), the DS200PCCAG7A generates less heat per watt delivered, improving reliability in moderately populated racks.
-
Higher surge protection – 2.5kV surge rating (vs. 2kV on 5A models) provides better resilience against lightning-induced transients and switching surges.
-
Compact 1-slot form factor – Fits in any standard Mark V slot without requiring adjacent empty space – critical for densely populated racks.
-
Simple AC-only input – No DC infrastructure required; operates directly from standard 115 VAC plant power.
-
Cost-effective mid-range option – The DS200PCCAG7A offers excellent value for medium-density installations, providing 40% more capacity than 5A models at a modest price increase.
-
Basic LED diagnostics – Four LEDs provide immediate visual status: AC input present, +5V output healthy, current limit active, and general fault.
Key Differences vs. DS200PCCAG2A (Newer 7A Revision)
| Feature | DS200PCCAG7A (7A, A Rev) | DS200PCCAG2A (Newer 7A) |
|---|---|---|
| Availability | Rare (8-12 weeks) | Uncommon (4-6 weeks) |
| Component Selection | Older parts (some obsolete) | Updated, more reliable components |
| Recommended Use | Legacy systems, specific replacements | Standard replacements (preferred) |
Key Takeaway: The DS200PCCAG7A is a reliable 7A power converter, but the DS200PCCAG2A is generally preferred for new replacements due to better availability and updated component selection.
Application Cases
-
Mid-sized combined-cycle plant – A 300 MW facility upgraded their Mark V rack from 12 to 20 analog input channels. Total +5V load increased from 4.5A to 6.8A. The original 5A board was insufficient, but the DS200PCCAG7A (7A) provided adequate headroom.
-
Industrial steam turbine with communication expansion – A chemical plant added two additional communication boards to their Mark V rack. The +5V load rose to 6.5A. The DS200PCCAG7A was selected due to the 1-slot form factor.
-
Gas compressor station – A pipeline facility with three compressor trains used the DS200PCCAG7A in their control racks. The 7A capacity supported dual processor boards and 16 I/O modules with comfortable 0.5A margin.
-
Hydroelectric upgrade – A dam facility replaced aging boards with the DS200PCCAG7A as part of a control system refresh, providing a 5-year growth path.
Comparison with Related Variants
| Feature | DS200PCCAG7A (7A, A Rev) | DS200PCCAG2A (Newer 7A) | DS200PCCAG1A (5A) | DS200PCCAG3A (9A) |
|---|---|---|---|---|
| +5V Capacity | 7A (8.5A peak) | 7A (8.5A peak) | 5A (6A peak) | 9A (11A peak) |
| Efficiency | 80% | 80% | 78% | 82% |
| Surge Protection | 2.5kV | 2.5kV | 2kV | 3kV |
| Diagnostic LEDs | 4 | 4 | 4 | 4 |
| Slot Width | 1-slot | 1-slot | 1-slot | 1-slot |
| Availability | Rare (8-12 weeks) | Uncommon (4-6 weeks) | Common (2-4 weeks) | Rare (6-10 weeks) |
| Cost | Moderate | Moderate | Low-moderate | Moderate-high |
| Best For | Medium I/O, legacy compatibility | Medium I/O (preferred) | Low I/O | High I/O |
Selection Suggestions
-
Calculate your +5V load accurately – Select the DS200PCCAG7A if the total is:
-
Between 5A and 7A continuous – ideal range.
-
Between 7A and 8A – consider the 9A DS200PCCAG3A for safety margin.
-
Under 5A – choose the 5A model to save cost.
-
-
Prefer the newer DS200PCCAG2A – The DS200PCCAG2A is generally more available and has better component support. Only select the DS200PCCAG7A if you have a specific compatibility requirement.
-
Confirm AC power availability – The DS200PCCAG7A accepts 115 VAC only.
-
Assess environmental conditions – No conformal coating. For harsh environments, choose the coated 5A options (if load allows) or the coated 10A DS200PCCAG10ACB.
-
Procurement – Purchase from reputable suppliers offering functional testing. Lead times: 8-12 weeks.
-
Stock spares – Maintain one on-site spare for critical applications.
Important Precautions
-
Power down completely – De-energize rack; wait 5 minutes for capacitor discharge. Hot-swapping not supported.
-
ESD protection – Use wrist strap and anti-static mat.
-
AC input only – Do not apply DC voltage.
-
Overtemperature reset – Red FAULT with OTP requires 15-minute cool-down, then manual power cycle.
-
Cooling requirements – 85 CFM minimum.
-
Fan replacement – Replace 40mm fan every 4 years.
-
Cleaning – Use compressed air only. No liquids.
-
Storage – Store at 10-30°C, 20-50% RH. Rotate every 24 months.
Final Expert Recommendation
The DS200PCCAG7A is a reliable 7A power converter for Mark V installations requiring medium capacity. It offers 40% more capacity than 5A models at a modest price increase, with 80% efficiency and 2.5kV surge protection.
However, the DS200PCCAG2A is generally preferred for new replacements due to better availability (4-6 weeks vs. 8-12 weeks) and updated component selection. Only select the DS200PCCAG7A if your system specifically requires this revision or you have a cost-effective source for it.
Select the DS200PCCAG7A when:
-
Your +5V load is between 5A and 7A
-
Your system has a specific compatibility requirement
-
You have a reliable source for this variant
For most applications, the DS200PCCAG2A is the more prudent choice. For loads above 7A, consider the DS200PCCAG3A (9A). For harsh environments, choose the coated options (DS200PCCAG1ABB, DS200PCCAG2ACB, or DS200PCCAG10ACB depending on load).
When sourcing the DS200PCCAG7A, ensure functional testing is performed and verify authenticity. With proper installation and maintenance, this board will provide dependable service for Mark V turbine control systems with medium power requirements.

GE 369B1860G0026
TRICONEX 4351B
TRICONEX 4351B


Reviews
There are no reviews yet.