Description

Specifications
- Part Number: 190065A-00-00-02-00-01
- Series: 1900/65A General Purpose Equipment Monitor
- Power supply: 18–36 VDC, typical power consumption 8.5 W
- Input channels: Multi configurable channels for proximity, velocity, acceleration and temperature (RTD / thermocouple)
- Outputs: 6 programmable SPDT alarm relays, 4 isolated 4–20 mA analog outputs, buffered raw signal output
- Communication: RS485 Modbus RTU
- Mounting: Bulkhead flush panel mount
- Indicators: OK, Alert, Danger LED indicators (no LCD screen)
- Operating temperature: -20°C ~ +70°C
- Humidity: 0–95%, non-condensing
- Configuration: 1900 Configuration software
Advantages and Features
BENTLY 190065A-00-00-02-00-01 is a cost-effective substitute for rack-type 3500 system for non-critical auxiliary machines. Each channel supports independent Alert and Danger threshold setting. Relay logic can be flexibly programmed for combined alarm interlock. Modbus RTU uploads real-time values, alarm status and event logs to automation systems. It has built-in transducer cable break diagnosis. It is compact, standalone and easy to install on local equipment cabinets.
Application & Case
It is widely applied to power plant auxiliary equipment, chemical and pulp & paper factory fans, pumps and compressors. In a power plant auxiliary transformation project, 190065A-00-00-02-00-01 replaced the faulty monitor. After parameter download, vibration monitoring, alarm relay action and 4-20mA transmission recovered normally.
Comparison
Different suffix codes of 1900/65A correspond to different mounting, display and communication options and cannot be interchanged directly. Compared with 3500 series, 1900/65A is for general auxiliary equipment, with lower cost and simpler functions. It cannot work with 3500 rack backplane.
Selection Notes
Confirm the full ordering code 190065A-00-00-02-00-01, confirm mounting opening size and Modbus communication requirement. It is not compatible with 3500 rack modules.
Precautions
Cut off DC power before replacement and take ESD protection. Verify transducer polarity and wiring. After installation, download configuration, calibrate channels, test 4-20mA output, alarm relay and Modbus data upload before commissioning.

HONEYWELL CC-TDOB11
HONEYWELL CC-TUI041 51306873-176
HONEYWELL CC-TUI041 CC-TUIO41
BERGHOF CDIO 16/16-0,5