Description
Product Description
Product Parameters
| Parameter Category | Specification |
|---|---|
| Core Function | Vibration signal conditioning, amplitude measurement, standardized 4–20 mA signal transmission |
| Input Compatibility | Bently Nevada 3300 Series accelerometers (ICP®/IEPE), velocity sensors |
| Output Signals | 4–20 mA DC (linear to RMS vibration amplitude); configurable alarm relay outputs (2 channels) |
| Measurement Range | 0–50 mm/s RMS (velocity); 0–50 g RMS (acceleration) |
| Accuracy | ±1% of full scale (typical) |
| Frequency Response | 5 Hz – 10 kHz (acceleration); 1 Hz – 1 kHz (velocity) |
| Diagnostic Capabilities | Sensor open/short circuit detection, signal overload alarm, module self-test |
| Communication Interface | Optional HART® protocol for remote configuration and monitoring |
| Operating Temperature | -40°C to +85°C (no derating) |
| Power Supply | 24 V DC (±15%); loop-powered or externally powered options |
| Protection Rating | IP65 (field-mountable); IP20 (rack-mountable) |
| Certifications | CE, UL, CSA, ATEX, IECEx, RoHS |
Advantages and Features
- High-Accuracy Vibration Measurement & Standardization
The BENTLY 127610-01 delivers ±1% full-scale accuracy, converting raw sensor signals into industry-standard 4–20 mA outputs that directly reflect RMS vibration amplitude. This precision ensures that maintenance teams can detect subtle vibration anomalies indicative of early-stage faults (e.g., bearing wear, gear tooth damage) before they lead to catastrophic equipment failure, reducing unplanned downtime by up to 40%.
- Dual-Purpose Mounting & Flexible Power Options
With both field-mountable (IP65) and rack-mountable (IP20) configurations, the BENTLY 127610-01 adapts to diverse installation scenarios—from harsh on-machine locations to centralized control cabinets. Its dual power options (loop-powered or external 24 V DC) eliminate wiring complexity, supporting both new system deployments and retrofits of existing machinery protection setups.
- Comprehensive Built-In Diagnostics
Equipped with real-time diagnostic functions, the BENTLY 127610-01 detects sensor open/short circuits, signal overloads, and internal module faults, triggering configurable relay alarms and HART® status messages. These diagnostics eliminate blind spots in condition monitoring systems, allowing teams to resolve issues during planned outages instead of emergency shutdowns.
- Rugged Design for Extreme Industrial Environments
Built to withstand the rigors of oil & gas, power generation, and heavy industrial facilities, the BENTLY 127610-01 operates reliably across a wide temperature range (-40°C to +85°C) and resists EMI from high-voltage equipment and variable frequency drives (VFDs). Its ATEX and IECEx certifications enable deployment in Zone 1/21 hazardous areas, ensuring safe operation in explosive atmospheres.
- Seamless Integration with Control Systems
The module’s 4–20 mA output and optional HART® protocol enable plug-and-play integration with PLC, DCS, and SCADA systems, while its configurable alarm relays provide direct safety interlock capabilities for critical machinery. This compatibility reduces system commissioning time by 30% and eliminates the need for third-party signal converters.
Application Cases in Application Fields
- Gas Turbine Vibration Protection (Power Generation)
A 1,200 MW combined-cycle power plant deploys the BENTLY 127610-01 to monitor vibration levels in gas turbine bearing housings. The module’s high accuracy detects a 5% increase in RMS vibration amplitude caused by lubrication degradation, triggering a predictive maintenance alarm. Teams schedule a lubricant change during a planned outage, avoiding an estimated $2.7 million in unplanned downtime and turbine damage.
- Offshore Compressor Condition Monitoring (Oil & Gas)
An offshore oil platform uses the BENTLY 127610-01 (field-mount, ATEX-certified) to monitor high-pressure gas compressor vibration. The module’s IP65 rating withstands salt spray and humid conditions, while its HART® interface enables remote configuration from the platform’s central control room. Accurate vibration data helps prevent compressor surge events, ensuring continuous gas production and reducing maintenance costs by 25%.
- Steel Mill Rolling Mill Vibration Monitoring (Heavy Industry)
A steel manufacturing facility integrates the BENTLY 127610-01 into its rolling mill machinery protection system, monitoring vibration in roll stand bearings. The module’s wide frequency response captures high-frequency vibration harmonics associated with roll wear, enabling predictive replacement of rolls before they cause product defects or equipment downtime.
- Wind Turbine Gearbox Health Monitoring (Renewable Energy)
A utility-scale wind farm leverages the BENTLY 127610-01 to monitor gearbox vibration in 3 MW wind turbines. The module’s loop-powered design simplifies wiring in remote turbine towers, while its diagnostic features detect sensor faults caused by extreme wind vibration. Predictive maintenance alerts reduce gearbox replacement downtime by 30% and extend gearbox service life by 15%.
Comparisons with Competing Products
| Feature | BENTLY 127610-01 | Competitor A (Generic Vibration Transmitter) | Competitor B (Basic Vibration Switch) |
|---|---|---|---|
| Measurement Accuracy | ±1% full scale | ±3% full scale | Non-linear, alarm-only output |
| Mounting Flexibility | IP65 field-mount / IP20 rack-mount | IP20 rack-mount only | IP65 field-mount only |
| Diagnostic Capabilities | Sensor fault + module self-test | Basic power alarm only | No diagnostics |
| Hazardous Area Approval | ATEX, IECEx Zone 1 | ATEX Zone 2 only | No hazardous certification |
| Communication | Optional HART® | No communication | No communication |
Selection Suggestions and Precautions
Selection Suggestions
- Prioritize for Bently Nevada 3300 Series Sensor Systems
Choose the BENTLY 127610-01 for use with Bently Nevada accelerometers and velocity sensors to ensure maximum signal integrity and calibration accuracy.
- Opt for Hazardous or Extreme Environment Deployments
Select the module for installations in ATEX/IECEx Zone 1 hazardous areas or extreme temperature environments (-40°C to +85°C) where generic transmitters would fail.
- Match with Remote Monitoring & Control Requirements
Pair the BENTLY 127610-01 with HART®-enabled DCS/SCADA systems to enable remote configuration, diagnostic data retrieval, and alarm management.
Precautions
- Sensor Compatibility Check
Ensure the BENTLY 127610-01 is paired with compatible Bently Nevada 3300 Series ICP®/IEPE accelerometers or velocity sensors; non-Bently sensors may cause measurement inaccuracies or trigger false alarms.
- Power Supply Compliance
Use a stable 24 V DC power source with ±15% tolerance; voltage fluctuations outside this range will degrade signal quality and damage the module over time.
- Wiring Guidelines for EMI Immunity
Route sensor cables away from high-voltage power lines and VFD output cables; maintain a minimum 30 cm separation to minimize electromagnetic interference with the BENTLY 127610-01’s input signals.
- Storage Conditions
Store spare BENTLY 127610-01 modules in a dry, temperature-controlled environment (0°C to +30°C) with relative humidity below 70%, and avoid exposure to strong magnetic fields that may disrupt internal circuitry.

ICS TRIPLEX T8312-4
ICS TRIPLEX T8310
P153/DL /002 ICS TRIPLEX
ICS TRIPLEX T8314
ICS TRIPLEX T8230
ICS TRIPLEX T8100
ICS TRIPLEX T8110



Reviews